Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization

被引:123
|
作者
Ricci, Renato Pietro [1 ]
Morichetli, Loredana [1 ]
Santini, Massimo [1 ]
机构
[1] San Filippro Neri Hosp, Dept Cardiovasc Dis, I-00135 Rome, Italy
来源
EUROPACE | 2008年 / 10卷 / 02期
关键词
home monitoring; telecardiology; atrial fibrillation; ventricular tachyarrhythmias; heart failure; cardiac pacing;
D O I
10.1093/europace/eum289
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the impact of Home Monitoring(TM)(HM) remote control on patient medical treatment and on health-care resource utilization. Methods and results One hundred and seventeen patients received HM pacemakers or defibrillators. A pacing expert nurse consulted daily the website and submitted critical cases to physician. During a mean follow-up of 227 +/- 128 days, 25 210 messages were received (23 545 daily messages and 1665 alert events) resulting in 90.7% of HM supervised days. Fifty-nine minutes/week for the nurse and 12 min/week for the physician were spent for HM data analysis during 267 web-connections. The mean connection time per patient was 115 +/- 60 s. The nurse submitted to the physician 133 critical cases in 56 patients. The diagnosis were atrial fibrillation (47%), ventricular tachyarrhythmias (9%), inappropriate implantable cardioverter defibrillator intervention (4%), unsustained ventricular tachycardia (7%), device suboptimal programming (23%), and impending heart failure (10%). Sixty-six unplanned follow-up in 43 patients led to drug therapy change (44%), device reprogramming (18%), diagnosis confirmation without further intervention (24%), no confirmation (6%), further diagnostic tests (9%). Conclusion HM technology allowed optimization of medical treatment and device programming with tow consumption of health-care resource.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 50 条
  • [21] Impact of Ranolazine on Clinical Outcomes and Health Care Resource Utilization in Patients With Angina Pectoris
    Ling, Hua
    Packard, Kathleen A.
    Burns, Tammy L.
    Hilleman, Daniel E.
    CIRCULATION, 2012, 126 (21)
  • [22] IMPACT OF A SINGLE-VENTRICLE INTERSTAGE HOME MONITORING AND CLINICAL MANAGEMENT PLAN ON INTERSTAGE OUTCOMES AND RESOURCE UTILIZATION
    Brown, David W.
    O'Brien, Pat
    Cohen, Katie E.
    Glynn, Matthew
    Saia, Terry
    Gauvreau, Kimberlee
    Fulton, David
    Pigula, Frank
    Jenkins, Kathy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E452 - E452
  • [23] Impact of Diabetes Mellitus (DM) on the Health-Care Utilization and Clinical Outcomes of Patients with Stroke in Singapore
    Sun, Yan
    Toh, Matthias Paul Han Sim
    VALUE IN HEALTH, 2009, 12 : S101 - S105
  • [24] Impact of hospitalization in patients with atrial fibrillation: Implications for health-care providers and clinical management
    Proietti, Marco
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 276 : 287 - 288
  • [25] The Impact of Proton Pump Inhibitor Compliance on Health-Care Resource Utilization and Costs in Patients with Gastroesophageal Reflux Disease
    Gosselin, Antoine
    Luo, Roger
    Lohoues, Herve
    Toy, Edmond
    Lewis, Barbara
    Crawley, Joseph
    Duh, Mei Sheng
    VALUE IN HEALTH, 2009, 12 (01) : 34 - 39
  • [26] Remote Management of Pacemaker Patients With Biennial In-Clinic Evaluation Continuous Home Monitoring in the Japanese At-Home Study: A Randomized Clinical Trial
    Watanabe, Eiichi
    Yamazaki, Fumio
    Goto, Toshihiko
    Asai, Toru
    Yamamoto, Toshihiko
    Hirooka, Keiji
    Sato, Toshiaki
    Kasai, Atsunobu
    Ueda, Marehiko
    Yamakawa, Takeshi
    Ueda, Yasunori
    Yamamoto, Katsuhito
    Tokunaga, Takeshi
    Sugai, Yoshinao
    Tanaka, Kazuhiko
    Hiramatsu, Shigeki
    Arakawa, Tomoharu
    Schrader, Juergen
    Varma, Niraj
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (05):
  • [27] Impact of financial incentives for inter-provider care coordination on health-care resource utilization among elderly acute stroke patients
    Nishi, Takumi
    Maeda, Toshiki
    Babazono, Akira
    INTERNATIONAL JOURNAL FOR QUALITY IN HEALTH CARE, 2017, 29 (04) : 490 - 498
  • [28] EARLY CLINICAL ASSESSMENT TRIGGERED BY REMOTE MONITORING IS ASSOCIATED WITH LOWER HEALTH CARE RESOURCE UTILIZATION IN A CHRONIC RESPIRATORY DISEASE COHORT
    Moraveji, Neema
    Teresi, Robert K.
    Hendricks, Ashley
    Polsky, Michael B.
    Murray, Richard K.
    CHEST, 2023, 164 (04) : 6535A - 6535A
  • [29] Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort: The IMPACT study
    Ip, John
    Waldo, Albert L.
    Lip, Gregory Y. H.
    Rothwell, Peter M.
    Martin, David T.
    Bersohn, Malcolm M.
    Choucair, Wassim K.
    Akar, Joseph G.
    Wathen, Mark S.
    Rohani, Pooyan
    Halperin, Jonathan L.
    AMERICAN HEART JOURNAL, 2009, 158 (03) : 364 - U10
  • [30] How well do results from large randomized clinical trials diffuse into clinical practice? Impact of MADIT-RIT in a large cohort of implantable cardioverter defibrillator patients (ALTITUDE)
    Varma, N.
    Jones, P.
    Wold, N.
    Stein, K.
    EUROPEAN HEART JOURNAL, 2014, 35 : 49 - 49