Objective: Study objectives were to assess the accuracy of a food record delivered on a personal digital assistant (PDA) and to examine sources of error from the PDA-based food record. Methods: Thirty-nine adults recruited with a newspaper advertisement were trained to record food intake using DietMatePro, a dietary assessment program delivered on a PDA. After 3 d of use, subjects returned for a follow-up visit in which a 24-h recall was conducted. Subjects also were timed while recording an observed, weighed lunch. Recalled and actual food intakes were compared with estimates recorded by the subjects when using the PDA. Paired sample t tests and Pearson's correlations assessed means and measurements of association between DietmatePro data compared with the 24-h recall data and observed meal data. Bland-Altman plots were used to assess bias in food recording. Sources of error were quantified by using calories as the unit for comparison. Results: There were no significant differences in daily totals for calories and macronutrients between DietMatePro data and comparison measurements. Pearson's correlations of associations between DietMatePro data and the comparison measurement ranged from 0.505 to 0.797 (P < 0.005, n = 28) for the 24-h recall and from 0.419 to 0.786 (P < 0.005, n = 33) for the observed lunch, depending on the nutrient measured. The largest source of absolute error in caloric estimation was attributable to portion size estimation error (49%). Conclusions: DietMatePro, a PDA-based dietary. assessment program, provides a method of assessing energy and macronutrient intakes comparable to the 24-h recall in samples lacking dietary restrictions. © 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:672 / 677
页数:6
相关论文
共 50 条
  • [31] Development of a PDA-based approach to link clinical patient care with daily student assessment.
    Pham, TD
    Said, M
    Wong, S
    Shuler, CF
    Snead, ML
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A506 - A506
  • [32] A PDA-Based Modular and Multipurpose System for Intelligent Ubiquitous Monitoring
    Presedo, J.
    Tarasco, M.
    Teijeiro, T.
    Castro, D.
    Felix, P.
    WISP 2009: 6TH IEEE INTERNATIONAL SYMPOSIUM ON INTELLIGENT SIGNAL PROCESSING, PROCEEDINGS, 2009, : 223 - 228
  • [33] A mobile solution: PDA-based platform for radiology information management
    Busch, JM
    Barbaras, L
    Wei, J
    Nishino, M
    Yam, CS
    Hatabu, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (01) : 237 - 242
  • [34] A PDA-based wireless liosensor using industry standard components
    Sommers, DR
    Stubbs, DD
    Hunt, WD
    IEEE SENSORS JOURNAL, 2004, 4 (05) : 551 - 558
  • [35] Design of a PDA-based Asthma Peak Flow Monitor System
    Wu, C. -M.
    Su, C. -W.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 501 - 504
  • [36] Calibration transfer between PDA-based NIR spectrometers in the NIR assessment of melon soluble solids content
    Greensill, CV
    Wolfs, PJ
    Spiegelman, CH
    Walsh, KB
    APPLIED SPECTROSCOPY, 2001, 55 (05) : 647 - 653
  • [37] A PDA-based ECG beat detector for home cardiac care
    Goh, K. W.
    Lavanya, J.
    Kim, Y.
    Tan, E. K.
    Soh, C. B.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 375 - 378
  • [38] PDA-based Boolean function simplification: a useful educational tool
    Bitincka, L
    Antoniou, GE
    INFORMATICA, 2004, 15 (03) : 329 - 336
  • [39] PDA-based graphical interchange for field service and repair workers
    Citrin, WV
    Gross, MD
    COMPUTERS & GRAPHICS, 1996, 20 (05) : 641 - 649
  • [40] A wireless PDA-based physiological monitoring system for patient transport
    Lin, YH
    Jan, IC
    Ko, PCI
    Chen, YY
    Wong, JM
    Jan, GJ
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2004, 8 (04): : 439 - 447