Design and fabrication of novel multi-channel floating neural probes for intracortical chronic recording

被引:30
|
作者
Schander, A. [1 ]
Stemmann, H. [2 ]
Tolstosheeva, E. [1 ]
Roese, R. [2 ]
Biefeld, V. [1 ]
Kempen, L. [1 ]
Kreiter, A. K. [2 ]
Lang, W. [1 ]
机构
[1] Univ Bremen, Inst Microsensors Actuators & Syst, Bremen, Germany
[2] Univ Bremen, Brain Res Inst, Bremen, Germany
关键词
Neural probe; Flexible ribbon cable; Floating implantation; Cortex; Polyimide BPDA-PPD; PEDOT:PSS; Chronic recording;
D O I
10.1016/j.sna.2016.05.034
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel design approach and production process flow for the fabrication of multi-channel silicon probes with highly flexible ribbon cables integrated monolithically on wafer level. The integrated flexible cables are based on the biocompatible polymer polyimide BPDA-PPD. Compared to state-of-the-art silicon probes, this novel design allows a floating chronic implantation of the probes into the cortex with reduced mechanical coupling to the skull. The electrode area is additionally coated with the electrical conductive and biocompatible polymer poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) to reduce the electrode interface impedance. In-vitro electrical impedance spectroscopy measurements demonstrate the functionality of these novel probes and verify a significant reduction of the electrode impedance using PEDOT:PSS coating. For precise and complete insertion of these neural probes in the cortex an insertion tool was developed, which can be attached to a variety of different electrode drives. Using this tool the silicon probes were successfully implanted into rat motor cortex. Prior to implantation the probes were steam autoclaved at 121 degrees C,1 bar for 20.5 min for sterilization. Electrophysiological recordings as well as in-vivo electrical impedance spectroscopy supported the results of the in-vitro functional tests. After an initial increase of electrical impedance in the course of the first week after implantation the average impedance of the electrodes settled for the following weeks. Recordings of single- and multi-unit activity along with the local field potential were successful for more than 7 weeks after implantation and are still continuing. These current results indicate an appropriate chronic use of the presented neural probes. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 135
页数:11
相关论文
共 50 条
  • [41] Design and Development of Advanced Multi-channel EMG Micro Electrode Recording System
    Raju, Venkateshwarla Rama
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 179 - 183
  • [42] Multi-channel deployment: a methodology for the design of multi-channel service processes
    Sousa, Rui
    Amorim, Marlene
    Pinto, Guida Marques
    Magalhaes, Ana
    PRODUCTION PLANNING & CONTROL, 2016, 27 (04) : 312 - 327
  • [43] A high precision analog multiplexer for multi-channel neural recording micro-systems
    Naghavi, Saeed
    Sharifi, Niloofar
    Abrishamifar, Adib
    MICROELECTRONICS JOURNAL, 2018, 71 : 8 - 18
  • [44] A Multi-Channel Neural Recording System with Adaptive Electrode Selection for High-Density Neural Interface
    Lee, Han-Sol
    Park, Hangue
    Lee, Hyung-Min
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4306 - 4309
  • [45] Design and Development of a novel Multi-channel Photoplethysmographic Research System
    Rybynok, V.
    May, J. M.
    Budidha, K.
    Kyriacou, P. A.
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 267 - 270
  • [46] Estimation of the intracortical neuronal dynamics from the multi-channel ECoG signals
    Sakatani, Tomoya
    Watanabe, Hidenori
    Togawa, Morio
    Yoshida, Masatoshi
    Hasegawa, Isao
    Suzuki, Takafumi
    Sato, Masa-aki
    Kawato, Mitsuo
    Isa, Tadashi
    NEUROSCIENCE RESEARCH, 2010, 68 : E326 - E326
  • [47] Relationship between intracortical electrode design and chronic recording function
    Karumbaiah, Lohitash
    Saxena, Tarun
    Carlson, David
    Patil, Ketki
    Patkar, Radhika
    Gaupp, Eric A.
    Betancur, Martha
    Stanley, Garrett B.
    Carin, Lawrence
    Bellamkonda, Ravi V.
    BIOMATERIALS, 2013, 34 (33) : 8061 - 8074
  • [48] Multi-Channel Graph Neural Networks
    Zhou, Kaixiong
    Song, Qingquan
    Huang, Xiao
    Zha, Daochen
    Zou, Na
    Hu, Xia
    PROCEEDINGS OF THE TWENTY-NINTH INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, 2020, : 1352 - 1358
  • [49] Multi-Channel Neural Network for Steganalysis
    Liu, Kai
    Li, Xuan
    Zhang, Qiong
    Kang, Xiangui
    2017 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC 2017), 2017, : 1210 - 1213
  • [50] Optical design and fabrication of a multi-channel imaging spectrometer for combustion flame monitoring
    Xie, Bingqing
    Chang, Jun
    Cai, Jing
    Chen, Weilin
    Wang, Wenxi
    Zhang, Xuecong
    Zhang, Yang
    Jiang, Huilin
    OPTICS EXPRESS, 2024, 32 (08): : 14755 - 14769