Design and fabrication of novel multi-channel floating neural probes for intracortical chronic recording

被引:30
|
作者
Schander, A. [1 ]
Stemmann, H. [2 ]
Tolstosheeva, E. [1 ]
Roese, R. [2 ]
Biefeld, V. [1 ]
Kempen, L. [1 ]
Kreiter, A. K. [2 ]
Lang, W. [1 ]
机构
[1] Univ Bremen, Inst Microsensors Actuators & Syst, Bremen, Germany
[2] Univ Bremen, Brain Res Inst, Bremen, Germany
关键词
Neural probe; Flexible ribbon cable; Floating implantation; Cortex; Polyimide BPDA-PPD; PEDOT:PSS; Chronic recording;
D O I
10.1016/j.sna.2016.05.034
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel design approach and production process flow for the fabrication of multi-channel silicon probes with highly flexible ribbon cables integrated monolithically on wafer level. The integrated flexible cables are based on the biocompatible polymer polyimide BPDA-PPD. Compared to state-of-the-art silicon probes, this novel design allows a floating chronic implantation of the probes into the cortex with reduced mechanical coupling to the skull. The electrode area is additionally coated with the electrical conductive and biocompatible polymer poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) to reduce the electrode interface impedance. In-vitro electrical impedance spectroscopy measurements demonstrate the functionality of these novel probes and verify a significant reduction of the electrode impedance using PEDOT:PSS coating. For precise and complete insertion of these neural probes in the cortex an insertion tool was developed, which can be attached to a variety of different electrode drives. Using this tool the silicon probes were successfully implanted into rat motor cortex. Prior to implantation the probes were steam autoclaved at 121 degrees C,1 bar for 20.5 min for sterilization. Electrophysiological recordings as well as in-vivo electrical impedance spectroscopy supported the results of the in-vitro functional tests. After an initial increase of electrical impedance in the course of the first week after implantation the average impedance of the electrodes settled for the following weeks. Recordings of single- and multi-unit activity along with the local field potential were successful for more than 7 weeks after implantation and are still continuing. These current results indicate an appropriate chronic use of the presented neural probes. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 135
页数:11
相关论文
共 50 条
  • [1] DESIGN AND FABRICATION OF MULTI-CONTACT FLEXIBLE SILICON PROBES FOR INTRACORTICAL FLOATING IMPLANTATION
    Schander, A.
    Tolstosheeva, E.
    Biefeld, V.
    Kempen, L.
    Stemmann, H.
    Kreiter, A.
    Lang, W.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 1739 - 1742
  • [2] Multi-Channel Neural Recording Implants: A Review
    Noshahr, Fereidoon Hashemi
    Nabavi, Morteza
    Sawan, Mohamad
    SENSORS, 2020, 20 (03)
  • [3] DESIGN, FABRICATION, AND IN-VIVO BEHAVIOR OF CHRONIC RECORDING INTRACORTICAL MICROELECTRODES
    SALCMAN, M
    BAK, MJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (04) : 253 - 260
  • [4] A multi-channel analog IC for in vitro neural recording
    袁丰
    王志功
    吕晓迎
    Journal of Semiconductors, 2016, 37 (02) : 146 - 151
  • [5] A multi-channel analog IC for in vitro neural recording
    Yuan Feng
    Wang Zhigong
    Lu Xiaoying
    JOURNAL OF SEMICONDUCTORS, 2016, 37 (02)
  • [6] A 4.86 μW/Channel Fully Differential Multi-Channel Neural Recording System
    Lee, Taeju
    Cha, Ji-Hyoung
    Han, Su-Hyun
    Kim, Seong-Jin
    Je, Minkyu
    2018 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2018, : 68 - 69
  • [7] Multi-Channel Microelectrode Array for Cortical Recording and Stimulation: Fabrication and Modification
    Chen, Sanyuan
    Pei, Weihua
    Gui, Qiang
    Chen, Yuanfang
    Zhao, Shanshan
    Chen, Hongda
    2013 8TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE NEMS 2013), 2013, : 395 - 398
  • [8] A 220nW Neural Amplifier for Multi-Channel Neural Recording Systems
    Kim, Jungsuk
    Chae, Moo Sung
    Liu, Wentai
    ISCAS: 2009 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-5, 2009, : 1257 - 1260
  • [9] A multi-channel analog IC for in vitro neural recording附视频
    袁丰
    王志功
    吕晓迎
    Journal of Semiconductors, 2016, (02) : 146 - 151
  • [10] A neural signal processor for an implantable multi-channel cortical recording microsystem
    Sodagar, Amir M.
    Wise, Kensall D.
    Najafi, Khalil
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3884 - +