THE CONSTRUCTION OF CAPACITIVE VOLTAGE DIVIDER FOR MEASURING ULTRAFAST PULSE VOLTAGE

被引:0
|
作者
Kovacevic, Uros [1 ]
Bajramovic, Zijad [2 ]
Jovanovic, Bojan [3 ]
Lazarevic, Djordje [4 ]
Djekic, Sasa [5 ]
机构
[1] Univ Belgrade, Fac Elect Engn, Bulevar Kralja Aleksandra 73, Belgrade 11000, Serbia
[2] Univ Sarajevo, Fac Elect Enginering, Sarajevo 71000, Bosnia & Herceg
[3] High Sch Tech Sci Zvecan, Zvecan, Serbia
[4] Vinca Inst Nucl Sci, Belgrade 11000, Serbia
[5] ZP ElektroDoboj, Elect Power Ind Republika Srpska, Doboj 74000, Bosnia & Herceg
关键词
UNCERTAINTY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The problem of pulse voltage measurements in the nanoseconds range has become of great importance with ongoing problems related to the construction of pulse fusion generators as well as with simulations of electromagnetic pulses related to the atmospheric nuclear explosion. Ultrafast pulses in the nanoseconds range can be measured by the capacitive voltage divider. The problem that arises with ultrafast voltage occurrence is inductivity. Under conditions of the nanoseconds pulse increase rate, conductors of about few centimeters should be regarded as inductivity. Therefore, capacitive divider can be treated as an equivalent RLC circuit. The ohmic resistance R in that equivalent circuit originates from the characteristic impedance (either 50 Omega or 75 Omega) and, depending on its design, it can introduce an additional parasite inductivity. The aim of this paper is to consider and analyze the constructive solutions of capacitive voltage divider for measuring ultrafast voltage occurrence. Three types of capacitive divider will be constructed for that purpose. The high-voltage capacitor of each divider will be gas capacitor (in order to avoid both electrostatic and electrodynamic influence on measurement accuracy). The variations between divider types will be made for low-voltage capacitor. The designed low-voltage capacitors will be: 1 - in the shape of 10 mica capacitors connected in a parallel with a discrete ending resistor of 50 Omega; 2 - in the form of gas trimmer capacitor with a discrete ending resistor of 50 Omega, and 3 - the continual mica capacitor with waveguide resistor of 50 Omega (L=0). Ultrafast pulse response will be measured with dividers constructed in such manner, and will be compared with the corresponding response obtained from the numerical simulations.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Analysis of the match problem of a capacitive voltage divider with a long measurement cable
    Yu, Bin-Xiong
    Li, Rui
    Su, Jian-Cang
    Zhao, Liang
    Zhang, Yu
    Zheng, Lei
    Zeng, Bo
    Cheng, Jie
    Gao, Peng-Cheng
    Xu, Xu-dong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (09)
  • [42] Influence of different input signals with nanosecond pulsewidth on capacitive voltage divider
    Ouyang, Jia
    Liu, Jinliang
    Tian, Liang
    Feng, Jiahuai
    Liu, Yonggui
    Gaodianya Jishu/High Voltage Engineering, 2004, 30 (12):
  • [43] Design of primary converter for electronic voltage transformers based on capacitive divider
    Xiao, Xia
    Zhang, Zhongxue
    Xu, Yan
    Ye, Miaoyuan
    Han, Shizhong
    Xiang, Ke
    Gaodianya Jishu/High Voltage Engineering, 2006, 32 (05): : 15 - 18
  • [44] A compact 70 kv capacitive voltage divider with a shielded transfer electrode
    Boyko, N. I.
    Evdoshenko, L. S.
    Ivanov, V. M.
    Khristenko, O. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2012, (06) : 41 - 46
  • [45] CAPACITIVE VOLTAGE DIVIDER FOR FAST-PINCH DISCHARGE EXPERIMENTS.
    Ishii, Shozo
    Horide, Akihiko
    Fukuta, Masahiro
    Furuhashi, Kazumi
    Hayashi, Izumi
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes, 1985, 24 (01): : 114 - 115
  • [46] Voltage divider for measuring megavolt pulses with nanosecond rise time
    Bastrikov, AN
    Kovalchuk, BM
    Kremnev, VV
    Kumpyak, EV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1995, 38 (04) : 474 - 476
  • [47] Reference Switching Impulse Voltage Measuring System Based on Correcting the Voltage Divider Response With Software
    Havunen, Jussi
    Hallstrom, Jari
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [48] Self-Correction Sensor for Measuring Medium DC Voltage Based on Resistance Voltage Divider
    Tang X.
    Pan P.
    Zhang F.
    Yan L.
    Lv Y.
    Wu Y.
    Rong M.
    Teklu B.G.
    CSEE Journal of Power and Energy Systems, 2022,
  • [49] Measuring method of complex number voltage to capacitive sensors
    Ding, XB
    Guo, JY
    Zhou, Z
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2002, : 724 - 726
  • [50] Simple and compact capacitive voltage probe for measuring voltage impulses up to 0.5 MV
    Pecquois, R.
    Pecastaing, L.
    de Ferron, A.
    Rivaletto, M.
    Pignolet, P.
    Novac, B. M.
    Smith, I. R.
    Adler, R. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (03):