Respiratory motion-compensated high-resolution 3D whole-heart T1ρ mapping

被引:40
|
作者
Qi, Haikun [1 ]
Bustin, Aurelien [1 ]
Kuestner, Thomas [1 ]
Hajhosseiny, Reza [1 ]
Cruz, Gastao [1 ]
Kunze, Karl [1 ,2 ]
Neji, Radhouene [1 ,2 ]
Botnar, Rene M. [1 ,3 ]
Prieto, Claudia [1 ,3 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, St Thomas Hosp, 3rd Floor,Lambeth Wing,Lambeth Palace Rd, London SE1 7EH, England
[2] Siemens Healthcare, MR Res Collaborat, Frimley, England
[3] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会;
关键词
T1 rho mapping; T1 rho preparation; Free-breathing; Myocardial tissue characterization; Non-contrast; Cardiovascular magnetic resonance; LATE GADOLINIUM ENHANCEMENT; CORONARY MR-ANGIOGRAPHY; MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; DISEASE; FEASIBILITY; RELAXATION; ARTIFACTS; CARTILAGE; TIME;
D O I
10.1186/s12968-020-0597-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiovascular magnetic resonance (CMR) T1 rho mapping can be used to detect ischemic or non-ischemic cardiomyopathy without the need of exogenous contrast agents. Current 2D myocardial T1 rho mapping requires multiple breath-holds and provides limited coverage. Respiratory gating by diaphragmatic navigation has recently been exploited to enable free-breathing 3D T1 rho mapping, which, however, has low acquisition efficiency and may result in unpredictable and long scan times. This study aims to develop a fast respiratory motion-compensated 3D whole-heart myocardial T1 rho mapping technique with high spatial resolution and predictable scan time. Methods The proposed electrocardiogram (ECG)-triggered T1 rho mapping sequence is performed under free-breathing using an undersampled variable-density 3D Cartesian sampling with spiral-like order. Preparation pulses with different T1 rho spin-lock times are employed to acquire multiple T1 rho-weighted images. A saturation prepulse is played at the start of each heartbeat to reset the magnetization before T1 rho preparation. Image navigators are employed to enable beat-to-beat 2D translational respiratory motion correction of the heart for each T1 rho-weighted dataset, after which, 3D translational registration is performed to align all T1 rho-weighted volumes. Undersampled reconstruction is performed using a multi-contrast 3D patch-based low-rank algorithm. The accuracy of the proposed technique was tested in phantoms and in vivo in 11 healthy subjects in comparison with 2D T1 rho mapping. The feasibility of the proposed technique was further investigated in 3 patients with suspected cardiovascular disease. Breath-hold late-gadolinium enhanced (LGE) images were acquired in patients as reference for scar detection. Results Phantoms results revealed that the proposed technique provided accurate T1 rho values over a wide range of simulated heart rates in comparison to a 2D T1 rho mapping reference. Homogeneous 3D T1 rho maps were obtained for healthy subjects, with septal T1 rho of 58.0 +/- 4.1 ms which was comparable to 2D breath-hold measurements (57.6 +/- 4.7 ms, P = 0.83). Myocardial scar was detected in 1 of the 3 patients, and increased T1 rho values (87.4 +/- 5.7 ms) were observed in the infarcted region. Conclusions An accelerated free-breathing 3D whole-heart T1 rho mapping technique was developed with high respiratory scan efficiency and near-isotropic spatial resolution (1.7 x 1.7 x 2 mm(3)) in a clinically feasible scan time of similar to 6 mins. Preliminary patient results suggest that the proposed technique may find applications in non-contrast myocardial tissue characterization.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Free-breathing 3D whole-heart joint T1/T2 mapping and water/fat imaging at 0.55 T
    Si, Dongyue
    Crabb, Michael G.
    Kunze, Karl P.
    Littlewood, Simon J.
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1511 - 1524
  • [22] Accelerated 3D free-breathing high-resolution myocardial T1ρ mapping at 3 Tesla
    Qi, Haikun
    Lv, Zhenfeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2520 - 2531
  • [23] Motion Corrected 3D Whole-Heart Vessel Wall Imaging
    Gastao J Lima da Cruz
    David Atkinson
    Markus Henningsson
    Rene M Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [24] 3D Whole-heart free-breathing qBOOST-T2 mapping
    Milotta, Giorgia
    Ginami, Giulia
    Bustin, Aurelien
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1673 - 1687
  • [25] Accelerated whole-heart 3D CSPAMM for myocardial motion quantification
    Rutz, Andrea K.
    Ryf, Salome
    Plein, Sven
    Boesiger, Peter
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 755 - 763
  • [26] High-resolution multi-breath-held 3D volumetric T1 mapping acquisition: analysis of volume measurements of small structures using a respiratory motion phantom
    Keigo Kawaji
    Sui-Cheng Wang
    Akiko Tanaka
    Hui Wang
    Roberto Lang
    Amit R Patel
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [27] Motion-compensated compression of 3D animation models
    Ahn, JH
    Kim, CS
    Kuo, CCJ
    Ho, YS
    ELECTRONICS LETTERS, 2001, 37 (24) : 1445 - 1446
  • [28] Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging
    Camila Munoz
    Aurelien Bustin
    Radhouene Neji
    Karl P. Kunze
    Christoph Forman
    Michaela Schmidt
    Reza Hajhosseiny
    Pier-Giorgio Masci
    Martin Zeilinger
    Wolfgang Wuest
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 22
  • [29] Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging
    Munoz, Camila
    Bustin, Aurelien
    Neji, Radhouene
    Kunze, Karl P.
    Forman, Christoph
    Schmidt, Michaela
    Hajhosseiny, Reza
    Masci, Pier-Giorgio
    Zeilinger, Martin
    Wuest, Wolfgang
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [30] 3D mapping with high-resolution images
    Toutin, T
    Chénier, R
    Carbonneau, Y
    Alcaïde, N
    GEOINFORMATION FOR EUROPEAN-WIDE INTEGRATION, 2003, : 121 - 125