On-Line Real-Time Monitoring of a Rapid Enzymatic Oil Degumming Process: A Feasibility Study Using Free-Run Near-Infrared Spectroscopy

被引:3
|
作者
Forsberg, Jakob [1 ]
Nielsen, Per Munk [2 ]
Engelsen, Soren Balling [1 ]
Sorensen, Klavs Martin [1 ]
机构
[1] Univ Copenhagen, Dept Food Sci, Food Analyt & Biotechnol, Rolighedsvej 26, DK-1958 Frederiksberg C, Denmark
[2] Novozymes, Oils & Fats Applicat Res, Biologiens Vej 2, DK-2800 Lyngby, Denmark
关键词
Near-infrared spectroscopy; process analytical technology (PAT); process control; processing technology; chemometrics; vegetable oil; oil refinement; variable selection; RAMAN-SPECTROSCOPY; TRANSESTERIFICATION; NIR;
D O I
10.3390/foods10102368
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Enzymatic degumming is a well established process in vegetable oil refinement, resulting in higher oil yield and a more stable downstream processing compared to traditional degumming methods using acid and water. During the reaction, phospholipids in the oil are hydrolyzed to free fatty acids and lyso-phospholipids. The process is typically monitored by off-line laboratory measurements of the free fatty acid content in the oil, and there is a demand for an automated on-line monitoring strategy to increase both yield and understanding of the process dynamics. This paper investigates the option of using Near-Infrared spectroscopy (NIRS) to monitor the enzymatic degumming reaction. A new method for balancing spectral noise and keeping the chemical information in the spectra obtained from a rapid changing chemical process is suggested. The effect of a varying measurement averaging window width (0 to 300 s), preprocessing method and variable selection algorithm is evaluated, aiming to obtain the most accurate and robust calibration model for prediction of the free fatty acid content (% (w/w)). The optimal Partial Least Squares (PLS) model includes eight wavelength variables, as found by rPLS (recursive PLS) calibration, and yields an RMSECV (Root Mean Square Error of Cross Validation) of 0.05% (w/w) free fatty acid using five latent variables.</p>
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Quantitative real-time monitoring of dryer effluent using fiber optic near-infrared spectroscopy
    Harris, SC
    Walker, DS
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2000, 89 (09) : 1180 - 1186
  • [22] Near-infrared spectroscopy as continuous real-time monitoring for kidney graft perfusion
    Enrico Vidal
    Angela Amigoni
    Valentina Brugnolaro
    Giulia Ghirardo
    Piergiorgio Gamba
    Andrea Pettenazzo
    Giovanni Franco Zanon
    Chiara Cosma
    Mario Plebani
    Luisa Murer
    Pediatric Nephrology, 2014, 29 : 909 - 914
  • [23] Near-infrared spectroscopy as continuous real-time monitoring for kidney graft perfusion
    Vidal, Enrico
    Amigoni, Angela
    Brugnolaro, Valentina
    Ghirardo, Giulia
    Gamba, Piergiorgio
    Pettenazzo, Andrea
    Zanon, Giovanni Franco
    Cosma, Chiara
    Plebani, Mario
    Murer, Luisa
    PEDIATRIC NEPHROLOGY, 2014, 29 (05) : 909 - 914
  • [24] NEAR-INFRARED SPECTROSCOPY AS A CONTINUOUS REAL-TIME MONITORING FOR KIDNEY GRAFT PERFUSION
    Vidal, Enrico
    Amigoni, Angela
    Varagnolo, Mariacristina
    Benetti, Elisa
    Ghirardo, Giulia
    Brugnolaro, Valentina
    Murer, Luisa
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 548 - 548
  • [25] Real-time monitoring of multiparameter in 1,3-propanediol production process with near-infrared spectroscopy
    Liang, Zijian
    Zhang, Chijian
    Hu, Liyun
    Cai, Yunlong
    Deng, Maolang
    VIBRATIONAL SPECTROSCOPY, 2025, 136
  • [26] Review of near-infrared spectroscopy as a process analytical technology for real-time product monitoring in dairy processing
    Pu, Yuan-Yuan
    O'Donnell, Colm
    Tobin, John T.
    O'Shea, Norah
    INTERNATIONAL DAIRY JOURNAL, 2020, 103
  • [27] On-line conversion monitoring of the solution polymerization of methyl methacrylate using near-infrared spectroscopy
    Cherfi, A
    Févotte, G
    MACROMOLECULAR CHEMISTRY AND PHYSICS, 2002, 203 (09) : 1188 - 1193
  • [28] On-line monitoring of alkali-free cloth/phenolic resin prepreg by near-infrared Spectroscopy
    Jiang, Bo
    Huang, Yu Dong
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2007, 26 (16) : 1625 - 1636
  • [29] Comparative study on the real-time monitoring of a fluid bed drying process of extruded granules using near-infrared spectroscopy and audible acoustic emission
    Aoki, Hisayoshi
    Hattori, Yusuke
    Sasaki, Tetsuo
    Otsuka, Makoto
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 619
  • [30] Real-Time Monitoring of Fecal Nitrogen Excretion to the Environment Using Near-Infrared Reflectance Spectroscopy: A Preliminary Study in Rabbits
    Fortatos, Efstathios
    Hadjigeorgiou, Ioannis
    Mountzouris, Konstantinos C.
    Papadomichelakis, George
    ENVIRONMENTS, 2023, 10 (12)