Baseline optimization of SQUID gradiometer for magnetocardiography

被引:5
|
作者
Li Hua [1 ,2 ,3 ,4 ]
Zhang Shu-Lin [1 ,2 ,3 ]
Qiu Yang [1 ,2 ,3 ,4 ]
Zhang Yong-Sheng [1 ,2 ,3 ]
Zhang Chao-Xiang [1 ,2 ,3 ]
Kong Xiang-Yan [1 ,2 ,3 ]
Xie Xiao-Ming [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, SIMIT, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[2] Collaborat CAS Shanghai, Joint Res Lab Superconduct & Bioelect, Shanghai 200050, Peoples R China
[3] FZJ, D-52425 Julich, Germany
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
SQUID; gradiometer; baseline optimization; magnetocardiography;
D O I
10.1088/1674-1056/24/2/028501
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
SQUID gradiometer techniques are widely used in noise cancellation for biomagnetic measurements. An appropriate gradiometer baseline is very important for the biomagnetic detection with high performance. By placing several magnetometers at different heights along the vertical direction, we could simultaneously obtain the synthetic gradiometers with different baselines. By using the traditional signal-to-noise ratio (SNR) as a performance index, we successfully obtain an optimal baseline for the magnetocardiography (MCG) measurement in a magnetically shielded room (MSR). Finally, we obtain an optimal baseline of 7 cm and use it for the practical MCG measurement in our MSR. The SNR about 38 dB is obtained in the recorded MCG signal.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] HTS SQUID gradiometer for application without shielding
    Schultze, V
    IJsselsteijn, R
    Chwala, A
    Oukhanski, N
    Zakosarenko, V
    Meyer, HG
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2002, 15 (01): : 120 - 125
  • [42] AN INTEGRATED DC SQUID GRADIOMETER FOR BIOMAGNETIC APPLICATION
    KOYANAGI, M
    KASAI, N
    CHINONE, K
    NAKANISHI, M
    KOSAKA, S
    HIGUCHI, M
    KADO, H
    IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (02) : 1166 - 1169
  • [43] Compensation Method of LTS SQUID Gradiometer Data
    Hou, Ruidong
    Guo, Ziqi
    Guo, Hua
    Qiao, Yanchao
    Liu, Jianying
    Qin, Jingxin
    APPLIED GEOPHYSICS, 2023, 22 (1) : 132 - 145
  • [44] Development of Active Shielding-Type MI Gradiometer and Application for Magnetocardiography
    Takiya, Takashi
    Uchiyama, Tsuyoshi
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (11)
  • [45] LTS SQUID gradiometer system for in vivo magnetorelaxometry
    Warzemann, L
    Schambach, J
    Weber, P
    Weitschies, W
    Kötitz, R
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1999, 12 (11): : 953 - 955
  • [46] LTS SQUID gradiometer system for in vivo magnetorelaxometry
    Warzemann, L.
    Schambach, J.
    Weber, P.
    Weitschies, W.
    Kötitz, R.
    Superconductor Science and Technology, 1999, 12 (11): : 953 - 955
  • [47] INTEGRATED GRADIOMETER WITH LARGE beta SQUID.
    Yoshida, K.
    Kohjiro, S.
    Enpuku, K.
    Yamafuji, K.
    IEEE Transactions on Magnetics, 1986, MAG-23 (02)
  • [48] APPLICATIONS OF A SQUID GRADIOMETER TO AIRBORNE GEOMAGNETIC MEASUREMENTS
    BURBANK, MB
    VRBA, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (05): : 833 - 833
  • [49] A High-Balance Planar SQUID Gradiometer
    Zhang, Xue
    Zhang, Guofeng
    Wang, Yongliang
    Rong, Liangliang
    Zhang, Shulin
    Wu, Jun
    Qiu, Longqing
    Xie, Xiaoming
    Wang, Zhen
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
  • [50] INTEGRATED GRADIOMETER WITH LARGE BETA-SQUID
    YOSHIDA, K
    KOHJIRO, S
    ENPUKU, K
    YAMAFUJI, K
    IEEE TRANSACTIONS ON MAGNETICS, 1987, 23 (02) : 1106 - 1109