Purpose The purpose of this study is to quantify the relationship between the fluid flow and pressure drop for perforated plates. The homogenization of non-uniform fluid flows is often accomplished by passing the fluid through perforated plates. The underlying principle for the accomplishment of flow homogenization is a tradeoff of pressure drop for flow uniformity. Design/methodology/approach The investigation, implemented by numerical simulation, is based on turbulent flow in pipes and across perforated plates. The approach is as follows: (a) to devise a model to determine pressure drop's fluid flow information from a single-aperture, (b) to obtain this information for apertures of different shapes, (c) to determine this type of information for perforated plates situated in a circular pipe, (d) to compare the entire perforated-plate pressure drop with that for a single-aperture modular and (e) to analyze two identical perforated plates in series. Findings The pressure drop results for the single-aperture modular model agreed very well with those for a whole perforated plate in a round pipe, therefore negating the need to simulate the more complex situation. In addition to the parametric study with aperture shape and Reynolds number, porosities (20-60 per cent) and plate thicknesses were also varied. The results obtained here compared favorably with experimental data. Originality/value This work demonstrates an efficient method for analyzing and obtaining useful pressure drop information for perforated plates. For the first time, the porous media approach for modeling perforated plates is compared directly to complete, full-scale perforated plate applications and identical plates in series.
引用
收藏
页码:4310 / 4333
页数:24
相关论文
共 50 条
  • [1] Fluidic control of reactor flow-Pressure drop matching
    Tesar, V.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2009, 87 (6A): : 817 - 832
  • [2] FLOW-PRESSURE DROP EQUATION SIMPLIFIES PNEUMATIC DESIGN.
    Hagstrom, E.
    Hydraulics and Pneumatics, 1985, 38 (10): : 76 - 77
  • [3] CALCULATION OF DRY PRESSURE-DROP ACROSS PERFORATED PLATES
    MUHLE, J
    CHEMIE INGENIEUR TECHNIK, 1972, 44 (1-2) : 72 - &
  • [4] Flow-pressure drop measurement and calculation in a tapered femoral artery of a dog
    Banerjee, RK
    Back, LH
    Cho, YI
    BIORHEOLOGY, 1995, 32 (06) : 655 - 684
  • [5] Pressure loss characteristics of orifice and perforated plates
    Gan, GH
    Riffat, SB
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 14 (02) : 160 - 165
  • [6] Flow-pressure characteristics of an Intersurgical adjustable pressure-limiting valve
    Spinney, S.
    Sprigge, K. A.
    Lawson, T.
    ANAESTHESIA, 2017, 72 (04) : 539 - 540
  • [7] Effect of chamfer geometry on the pressure drop of perforated plates with thin orifices
    Barros Filho, Jose A.
    Santos, Andre A. C.
    Navarro, Moyses A.
    Jordao, Elizabete
    NUCLEAR ENGINEERING AND DESIGN, 2015, 284 : 74 - 79
  • [8] THE FLOW-PRESSURE CHARACTERISTICS OF COMPRESSORS USED FOR INHALATION-THERAPY
    NEWMAN, SP
    PELLOW, PGD
    CLARKE, SW
    EUROPEAN JOURNAL OF RESPIRATORY DISEASES, 1987, 71 (02): : 122 - 126
  • [9] Random vibration characteristics of perforated plates in parallel flow
    Xue, Cheng
    Zhu, Baoshan
    Liu, Xiaobing
    Nekomoto, Yoshitsugu
    Liu, Jinsheng
    Liu, Dongni
    29TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2019, 240
  • [10] The effect of protein and blood cells on the flow-pressure characteristics of shunts
    Brydon, HL
    Bayston, R
    Hayward, R
    Harkness, W
    NEUROSURGERY, 1996, 38 (03) : 498 - 504