Liquid scintillation determination of low level components in complex mixtures of radionuclides

被引:18
|
作者
Kashirin, IA
Ermakov, AI
Malinovskiy, SV
Belanova, SV
Sapozhnikov, YA
Efimov, KM
Tikhomirov, VA
Sobolev, AI
机构
[1] Sci Ind Assoc Radon, Moscow 119121, Russia
[2] Moscow State Univ, Dept Chem, Moscow 119899, Russia
[3] Inst Ecol Technol Problems, Moscow 113638, Russia
关键词
liquid scintillation counting; quenching; spectra decoding;
D O I
10.1016/S0969-8043(00)00145-7
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A new approach to simultaneous activity measurements of the complex radionuclide mixtures using liquid scintillation counting, which is applicable to the analysis of the environmental and technological samples, is presented. The method is based on specially developed software 'SpectraDec', realized on a Windows 95/98/NT platform and a spectra library created for different kinds and levels of quenching. The method allows analysis of complex mixtures when the activity ratios of the individual components vary considerably, For example, the radionuclide concentrations were successfully determined in the following complex mixture: H-3, Ni-63, Sr-90 + Y-90, Cs-137, Am-241 (model mixture), where the Sr-90 + Y-90/H-3 activity ratio was 1/2500 (0.2 Bq/500 Bq) and Sr-90, Cs-137, Cs-134, Th-232, Ra-226 (IAEA-reference sample), where the Sr-90/Cs-137 activity ratio was 1/50 (92 Bq/4515 Bq) with an accuracy of about 20%, The limitations of the given approach to the LS analysis of the radionuclide mixtures are considered. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条