Liquid scintillation determination of low level components in complex mixtures of radionuclides

被引:18
|
作者
Kashirin, IA
Ermakov, AI
Malinovskiy, SV
Belanova, SV
Sapozhnikov, YA
Efimov, KM
Tikhomirov, VA
Sobolev, AI
机构
[1] Sci Ind Assoc Radon, Moscow 119121, Russia
[2] Moscow State Univ, Dept Chem, Moscow 119899, Russia
[3] Inst Ecol Technol Problems, Moscow 113638, Russia
关键词
liquid scintillation counting; quenching; spectra decoding;
D O I
10.1016/S0969-8043(00)00145-7
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A new approach to simultaneous activity measurements of the complex radionuclide mixtures using liquid scintillation counting, which is applicable to the analysis of the environmental and technological samples, is presented. The method is based on specially developed software 'SpectraDec', realized on a Windows 95/98/NT platform and a spectra library created for different kinds and levels of quenching. The method allows analysis of complex mixtures when the activity ratios of the individual components vary considerably, For example, the radionuclide concentrations were successfully determined in the following complex mixture: H-3, Ni-63, Sr-90 + Y-90, Cs-137, Am-241 (model mixture), where the Sr-90 + Y-90/H-3 activity ratio was 1/2500 (0.2 Bq/500 Bq) and Sr-90, Cs-137, Cs-134, Th-232, Ra-226 (IAEA-reference sample), where the Sr-90/Cs-137 activity ratio was 1/50 (92 Bq/4515 Bq) with an accuracy of about 20%, The limitations of the given approach to the LS analysis of the radionuclide mixtures are considered. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 50 条
  • [1] Liquid scintillation counting for determination of radionuclides in environmental and nuclear application
    Hou, Xiaolin
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (03) : 1597 - 1628
  • [2] Liquid scintillation counting for determination of radionuclides in environmental and nuclear application
    Xiaolin Hou
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 : 1597 - 1628
  • [3] Radioactivity determination of individual radionuclides in a mixture by liquid scintillation spectra deconvolution
    Altzitzoglou, T.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 1055 - 1061
  • [4] Scintillation material for determination of radionuclides in water
    Andryushchenko, AY
    Blank, AB
    Budakovsky, SV
    Galunov, NZ
    Shevtsov, NI
    Tarasenko, OA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (03): : 425 - 430
  • [5] The effect of sample stability on the determination of radioactivity for various radionuclides by liquid scintillation counting
    Feng, Xiao-gui
    He, Qian-ge
    Wang, Jian-chen
    Chen, Jing
    APPLIED RADIATION AND ISOTOPES, 2015, 104 : 147 - 154
  • [6] Determination of low level 241Pu in environmental samples by liquid scintillation counting
    Lee, MH
    Lee, CW
    RADIOCHIMICA ACTA, 1999, 84 (04) : 177 - 181
  • [7] DETERMINATION OF AL-26 USING A LOW-LEVEL LIQUID SCINTILLATION SPECTROMETER
    BJORNSTAD, HE
    OUGHTON, DH
    SALBU, B
    ANALYST, 1992, 117 (03) : 435 - 438
  • [8] LIQUID SCINTILLATION COUNTING OF LOW LEVEL TRITIUM AS HYDROCARBONS
    PERSCHKE, H
    FLORKOWSKI, T
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (12): : 747 - +
  • [9] Computer system of low level liquid scintillation counter
    Ruan, Chengwen
    Xie, Yuanming
    Guan, Sanyuan
    Jiao, Wenqiang
    Qu, Xin
    Ji, Weitong
    Deng, Sujuan
    Zhang, Qingjun
    Liu, Jingyuan
    He Jishu/Nuclear Techniques, 20 (09): : 551 - 554
  • [10] Rapid determination of radiostrontium in milk using automated radionuclides separator and liquid scintillation counter
    Chung, Kun Ho
    Kim, Hyuncheol
    Lim, Jong Myoung
    Ji, Young-Yong
    Choi, Geun-Sik
    Kang, Mun Ja
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 304 (01) : 293 - 300