Signal processing method for flight time measurement of gas ultrasonic flowmeter

被引:0
|
作者
Zheng, Dandan [1 ]
Mei, Jianqiang [2 ]
Mao, Yang [1 ]
Yang, Zhibin [1 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin, Peoples R China
[2] Tianjin Univ Technol & Educ, Sch Elect Engn, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
time of flight; gas ultrasonic flowmeter; double-threshold method; THRESHOLD;
D O I
10.1109/I2MTC50364.2021.9459938
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Gas ultrasonic flowmeters are widely applied in industry because of high accuracy. The time of flight (TOF) measurement is significant which determines the flowmeter performance. The traditional TOF method are easily influenced by unstable flow and noise that leads to bad results especially in large velocities. In this paper, a new signal processing method based on the double-threshold method is proposed. The peak's characteristics of the received signal are used to find the feature point on the received signal, and then using this feature point and the zero-crossing detection to complete the calculation of TOF. By comparing the new method with other traditional method based on flow experiments, higher precision and reliability are obtained. And the calibration test results show that the flowmeter can achieve 1% measurement error in the wide flowrate range from 1m/s to 35m/s.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Research on Transit-time Ultrasonic Flowmeter with Signal Characteristic Analysis
    Li, Bin
    Xu, Jingyuan
    Chen, Jie
    Gou, Yang
    Nie, Zhigang
    2019 6TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2019), 2019, : 1131 - 1135
  • [32] Research and application of measurement performance standard specification of gas ultrasonic flowmeter
    Tao C.
    Ding Y.
    Wang Y.
    Li P.
    Zhang S.
    Yu D.
    Natural Gas Industry, 2022, 42 : 131 - 138
  • [33] TRANSIT-TIME ULTRASONIC FLOWMETER WITH PATENTED SIGNAL-CODING
    SCELZO, M
    JACOBSON, S
    MEASUREMENTS & CONTROL, 1994, (164): : 84 - 87
  • [34] A time-varying signal processing method for Coriolis mass flowmeter based on adaptive filter
    Feng Dan
    Fan Shangchun
    Zheng Dezhi
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2018, 40 (01) : 261 - 268
  • [35] Ultrasonic measurement of viscosity: Signal processing methodologies
    Franco, Ediguer E.
    Buiochi, Flavio
    ULTRASONICS, 2019, 91 : 213 - 219
  • [36] A measurement method based on Kalman filtering for ultrasonic time-of-flight estimation
    Angrisani, L
    Baccigalupi, A
    Lo Moriello, RS
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (02) : 442 - 448
  • [37] RESEARCH ON THE MEASUREMENT ACCURACY OF ULTRASONIC PHASED ARRAY TIME-OF-FLIGHT METHOD
    Liu, Shu H.
    Ding, Ju
    Wang, Jie L.
    PROCEEDINGS OF THE ASME 2020 PRESSURE VESSELS & PIPING CONFERENCE (PVP2020), VOL 7, 2020,
  • [38] A Novel Signal Processing Method for the Measurement of Venous Refilling Time
    Mohan, Madhu N.
    Mariappan, Leo
    Kumar, Jagadeesh, V
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1465 - 1468
  • [39] Signal processing method for Coriolis flowmeter based on time-varying signal model and normalized lattice notch filter
    Ni, Wei
    Xu, Ke-Jun
    Jiliang Xuebao/Acta Metrologica Sinica, 2007, 28 (03): : 243 - 247
  • [40] Research on high-precision time measurement technology in ultrasonic flowmeter
    Xie, Hai
    Chen, Shangsong
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (SUPPL.): : 209 - 212