Validity of Measurement for Trailing Limb Angle and Propulsion Force during Gait Using a Magnetic Inertial Measurement Unit

被引:16
|
作者
Miyazaki, Takasuke [1 ,2 ]
Kawada, Masayuki [3 ]
Nakai, Yuki [1 ]
Kiyama, Ryoji [3 ]
Yone, Kazunori [3 ]
机构
[1] Kagoshima Univ, Grad Sch Hlth Sci, 8-35-1 Sakuragaoka, Kagoshima, Kagoshima 8908544, Japan
[2] Tarumizu Cent Hosp, Tarumizu Municipal Med Ctr, Dept Rehabil, 1-140 Kinkocho, Tarumizu, Kagoshima 8912124, Japan
[3] Kagoshima Univ, Fac Med, Sch Hlth Sci, Course Phys Therapy, 8-35-1 Sakuragaoka, Kagoshima, Kagoshima 8908544, Japan
关键词
GROUND REACTION FORCES; PARETIC PROPULSION; WALKING; SPEED; ANKLE; INDIVIDUALS; ADAPTATION; KINEMATICS; MOBILITY; BALANCE;
D O I
10.1155/2019/8123467
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Propulsion force and trailing limb angle (TLA) are meaningful indicators for evaluating quality of gait. This study examined the validity of measurement for TLA and propulsion force during various gait conditions using magnetic inertial measurement units (IMU), based on measurements using a three-dimensional motion analysis system and a force platform. Eighteen healthy males (mean age 25.2 +/- 3.2 years, body height 1.70 +/- 0.06 m) walked with and without trunk fluctuation at preferred, slow, and fast velocities. IMU were fixed on the thorax, lumbar spine, and right thigh and shank. IMU calculated the acceleration and tilt angles in a global coordinate system. TLA, consisting of a line connecting the hip joint with the ankle joint, and the laboratory's vertical axis at late stance in the sagittal plane, was calculated from thigh and shank segment angles obtained by IMU, and coordinate data from the motion analysis system. Propulsion force was estimated by the increment of velocity calculated from anterior acceleration measured by IMU fixed on the thorax and lumbar spine, and normalized impulse of the anterior component of ground reaction force (AGRF) during late stance. Similarity of TLA measured by IMU and the motion analysis system was tested by the coefficient of multiple correlation (CMC), intraclass correlation coefficient (ICC), and root mean square (RMS) of measurement error. Relationships between normalized impulse of AGRF and increments of velocity, as measured by IMU, were tested using correlation analysis. CMC of TLA was 0.956-0.959. ICC between peak TLAs was 0.831-0.876 (p<0.001), and RMS of error was 1.42 degrees-1.92 degrees. Velocity increment calculated from acceleration on the lumbar region showed strong correlations with normalized impulse of AGRF (r=0.755-0.892, p<0.001). These results indicated a high validity of estimation of TLA and propulsion force by IMU during various gait conditions; these methods would be useful for best clinical practice.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Ship Motion Measurement Using an Inertial Measurement Unit
    Abankwa, Nana O.
    Johnston, Steven J.
    Scott, Mark
    Cox, Simon J.
    2015 IEEE 2ND WORLD FORUM ON INTERNET OF THINGS (WF-IOT), 2015, : 375 - 380
  • [22] Validity of a Commercially Available Inertial Measurement Unit for Vertical Jump Height Measurement
    Crisafulli, Gregory A.
    Taylor, Jeffrey B.
    Anh-Dung Nguyen
    Ford, Kevin R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 436 - 436
  • [23] A Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information
    Strick, Jacob A.
    Farris, Ryan J.
    Sawicki, Jerzy T.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (04):
  • [24] Lower Limb Gait Activity Recognition Using Inertial Measurement Units for rehabilitation robotics
    Hamdi, Mohammed M.
    Awad, Mohammed I.
    Abdelhameed, Magdy M.
    Tolbah, Farid A.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2015, : 316 - 322
  • [25] Automatic Body Segment and Side Recognition of an Inertial Measurement Unit Sensor during Gait
    Baniasad, Mina
    Martin, Robin
    Crevoisier, Xavier
    Pichonnaz, Claude
    Becce, Fabio
    Aminian, Kamiar
    SENSORS, 2023, 23 (07)
  • [26] Validation of a Rowing Oar Angle Measurement System based on an Inertial Measurement Unit
    Gravenhorst, Franz
    Troester, Gerhard
    Turner, Timothy
    Smith, Richard M.
    Draper, Conny
    2013 12TH IEEE INTERNATIONAL CONFERENCE ON TRUST, SECURITY AND PRIVACY IN COMPUTING AND COMMUNICATIONS (TRUSTCOM 2013), 2013, : 1412 - 1419
  • [27] Estimation of the External Knee Adduction Moment during Gait Using an Inertial Measurement Unit in Patients with Knee Osteoarthritis
    Iwama, Yu
    Harato, Kengo
    Kobayashi, Shu
    Niki, Yasuo
    Ogihara, Naomichi
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    SENSORS, 2021, 21 (04) : 1 - 10
  • [28] Early Detection of Freezing of Gait during Walking Using Inertial Measurement Unit and Plantar Pressure Distribution Data
    Pardoel, Scott
    Shalin, Gaurav
    Nantel, Julie
    Lemaire, Edward D.
    Kofman, Jonathan
    SENSORS, 2021, 21 (06)
  • [29] Gait phase detection based on inertial measurement unit and force-sensitive resistors embedded in a shoe
    Liu, Xianwen
    Zhang, Shimin
    Yao, Benchun
    Yu, Yang
    Wang, Yusong
    Fan, Jinchao
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (08):
  • [30] Monitoring of Hip and Knee Joint Angles Using a Single Inertial Measurement Unit During Lower Limb Rehabilitation
    Bonnet, Vincent
    Joukov, Vladimir
    Kulic, Dana
    Fraisse, Philippe
    Ramdani, Nacim
    Venture, Gentiane
    IEEE SENSORS JOURNAL, 2016, 16 (06) : 1557 - 1564