Analysis of Myocardial Ischemia Parameters after Coronary Artery Bypass Grafting with Minimal Extracorporeal Circulation and a Novel Microplegia versus Off-Pump Coronary Artery Bypass Grafting

被引:3
|
作者
Koechlin, Luca [1 ]
Zenklusen, Urs [1 ]
Doebele, Thomas [1 ]
Rrahmani, Bejtush [1 ]
Gahl, Brigitta [1 ]
Schaeffer, Thibault [1 ]
Berdajs, Denis [1 ]
Eckstein, Friedrich S. [1 ]
Reuthebuch, Oliver [1 ]
机构
[1] Univ Hosp Basel, Dept Cardiac Surg, Basel, Switzerland
关键词
ON-PUMP; 5-YEAR OUTCOMES; ASSOCIATION; MORTALITY; TROPONIN; TRENDS;
D O I
10.1155/2020/5141503
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Background. To compare the performance of our institutionally refined microplegia protocol in conjunction with minimal extracorporeal circulation system (MiECC) with off-pump coronary artery bypass grafting (OPCAB). Methods. We conducted a single center study including patients undergoing isolated CABG surgery performed either off-pump or on-pump using our refined microplegia protocol in conjunction with MiECC. We used propensity modelling to calculate the inverse probability of treatment weights (IPTW). Primary endpoints were peak values of high-sensitivity cardiac troponin T (hs-cTnT) during hospitalization, and respective first values on the first postoperative day. Endpoint analysis was adjusted for intraoperative variables. Results. After IPTW, we could include 278 patients into our analyses, 153 of which had received OPCAB and 125 of which had received microplegia. Standardized differences indicated that treatment groups were comparable after IPTW. The multivariable quantile regression yielded a nonsignificant median increase of first hs-cTnT by 39 ng/L (95% CI -8 to 87 ng/L, p=0.11), and of peak hs-cTnT by 35 ng/L (CI -13 to 84, p=0.16), when microplegia was used, as compared to OPCAB. Major adverse cardiac and cerebrovascular events (MACCE) occurred with equal frequency in both groups (7.8% vs. 5.0%; p=0.51), and length of stay in the intensive care unit (ICU) was significantly shorter after the use of microplegia (geometric mean 1.6 days versus 1.3 days; p=0.01). Conclusion. The use of our institutionally refined microplegia in conjunction with MiECC was associated with similar results with regard to ischemic injury, expressed in hs-cTnT compared to OPCAB. MACCE was seen equally frequent. ICU discharge was earlier if microplegia was used.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Off-pump coronary artery bypass grafting for acute myocardial infarction
    Takai, Hideaki
    Kobayashi, Junjiro
    Tagusari, Osamu
    Bando, Ko
    Niwaya, Kazuo
    Nakajima, Hiroyuki
    Yagihara, Toshikatsu
    Kitamura, Soichiro
    CIRCULATION JOURNAL, 2006, 70 (10) : 1303 - 1306
  • [32] On-pump and off-pump coronary artery bypass grafting
    Shekar, PS
    CIRCULATION, 2006, 113 (04) : E51 - E52
  • [33] How Minimalized Extracorporeal Circulation Compares with the Off-Pump Technique in Coronary Artery Bypass Grafting
    Harling, Leanne
    Warren, Oliver J.
    Rogers, Paula L. B.
    Watret, Amy L.
    Choong, Andrew M.
    Darzi, Ara
    Angelini, Gianni D.
    Athanasiou, Thanos
    ASAIO JOURNAL, 2010, 56 (05) : 446 - 456
  • [34] When and how to shunt the coronary circulation in off-pump coronary artery bypass grafting
    van Aarnhem, EEHL
    Nierich, AP
    Jansen, EWL
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 16 : S2 - S6
  • [35] OFF-PUMP CORONARY ARTERY BYPASS GRAFTING VERSUS CONVENTIONAL CORONARY ARTERY BYPASS GRAFTING: WHAT WE DON'T KNOW
    Ferguson, T. Bruce, Jr.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (03): : 893 - 894
  • [36] Comparison of Frequency of Postoperative Stroke in Off-Pump Coronary Artery Bypass Grafting Versus On-Pump Coronary Artery Bypass Grafting Versus Percutaneous Coronary Intervention
    Marui, Akira
    Kimura, Takeshi
    Tanaka, Shiro
    Okabayashi, Hitoshi
    Komiya, Tatsuhiko
    Furukawa, Yutaka
    Kita, Toru
    Sakata, Ryuzo
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (12): : 1773 - 1778
  • [37] Results of On-Pump Versus Off-Pump Coronary Artery Bypass Grafting
    Bolourian, Ali Asghar
    Foroughi, Mahnoosh
    Beheshty, Mahmood
    Hekmat, Manouchehr
    Majidi, Masood
    Hassantash, Seyed Ahmad
    ANNALS OF THORACIC SURGERY, 2010, 90 (01): : 358 - 358
  • [38] Effects of on-pump versus off-pump coronary artery bypass grafting on myocardial metabolism
    Xie, Hong-tao
    Kang, Xiao-qin
    Zhang, Shun
    Tian, Yong-cang
    Liu, De-jun
    Bai, Ben-jian
    MEDICINE, 2019, 98 (17)
  • [39] Coronary artery bypass grafting with minimal versus conventional extracorporeal circulation; an economic analysis
    Anastasiadis, K.
    Fragoulakis, V.
    Antonitsis, P.
    Maniadakis, N.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (06) : 5336 - 5343
  • [40] Economic analysis of coronary artery bypass grafting with minimal versus conventional extracorporeal circulation
    K Anastasiadis
    V Fragoulakis
    P Antonitsis
    N Maniadakis
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)