Photoacoustic imaging with attenuation rectification of different frequent components of photoacoustic signal

被引:6
|
作者
Tan, Y [1 ]
Xing, D [1 ]
Wang, Y [1 ]
Yang, DW [1 ]
机构
[1] S China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Peoples R China
关键词
photoacoustic imaging; photoacoustic signal; attenuation; rectification;
D O I
10.1117/12.573510
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Photoacoustic tomography is a potential and noninvasive medical imaging technology. It combines the advantages of pure optic imaging and pure ultrasound imaging. Photoacoustic signals induced by a short pulse laser cover a wide spectral range. We have explored the influences of attenuation of photoacoustic signals, which vary according to frequencies, to the quality of reconstructed photoacoustic images. It reveals that the attenuation of low frequent components are less than that of high frequencies, and the latter is more important for photoacoustic imaging with high resolution. Based on the ultrasonic attenuation theory, the photoacoustic imaging with rectification of the attenuation of different frequent component was performed. The experiments results show that this method improves the resolution of reconstructed images, which improves from 0.3mm to 0.2mm. A Q-switched Nd:YAG laser operating at 1064nm was used as light source. The laser had a pulse width of 6ns and a repetition frequency of 20Hz. A needle PVDF hydrophone with diameter of 1mm was used to detect photoacoustic signals.
引用
收藏
页码:668 / 674
页数:7
相关论文
共 50 条
  • [41] Thermoacoustic amplification of photoacoustic signal
    Harren, FJM
    Bijnen, FGC
    vonDongen, J
    Reuss, J
    Parker, DH
    9TH INTERNATIONAL CONFERENCE ON PHOTOACOUSTIC AND PHOTOTHERMAL PHENOMENA, CONFERENCE DIGEST, 1996, : 548 - 549
  • [42] Elimination of Nontargeted Photoacoustic Signals for Combined Photoacoustic and Ultrasound Imaging
    Kim, Haemin
    Lee, Hohyeon
    Kim, Hyuncheol
    Chang, Jin Ho
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (05) : 1593 - 1604
  • [43] Background signal in a photoacoustic system
    Hao, LY
    Shi, QA
    Cheng, GS
    Hu, SM
    Zheng, Y
    Zhu, QS
    PROGRESS IN NATURAL SCIENCE, 2001, 11 : S248 - S251
  • [44] Signal Processing for Photoacoustic Tomography
    Moock, V.
    Garcia-Segundo, C.
    Garduno, E.
    Arambula Cosio, F.
    Jithin, J.
    van Es, P.
    Manohar, S.
    Steenbergen, W.
    2012 5TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), 2012, : 957 - 961
  • [45] The signal compensation of photoacoustic tomography
    Zeng, YG
    Xing, D
    Yao, Y
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 221 - 226
  • [46] Attenuation Compensation for High-frequency Acoustic-Resolution Photoacoustic Imaging
    Jin, Haoran
    Liu, Siyu
    Zhang, Ruochong
    Zheng, Zesheng
    Zheng, Yuanjin
    2020 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2020,
  • [47] Experimental evaluation of time domain models for ultrasound attenuation losses in photoacoustic imaging
    Roitner, H.
    Bauer-Marschallinger, J.
    Berer, T.
    Burgholzer, P.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (05): : 3763 - 3774
  • [48] Photoacoustic Imaging Optimization with raw signal deconvolution and empirical mode decomposition
    Guo, Chengwen
    Wang, Jing
    Qin, Yu
    Zhan, Hongchen
    Yuan, Jie
    Cheng, Qian
    Wang, Xueding
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [49] COMPARISON BETWEEN THE DEPTH RESOLUTION OF THE SIGNAL AND THE PHASE IN PHOTOACOUSTIC IMAGING APPLICATIONS
    WILLIAMS, AW
    WOOD, NJ
    NDT & E INTERNATIONAL, 1993, 26 (05) : 231 - 234
  • [50] Progress of photoacoustic imaging combined with targeted photoacoustic contrast agents in tumor molecular imaging
    Zheng, Yiwen
    Liu, Mengyao
    Jiang, Lixin
    FRONTIERS IN CHEMISTRY, 2022, 10