Biomechanical Evaluation of Screw-In Femoral Implant in Cementless Total Hip System

被引:12
|
作者
Kim, James Y. [1 ]
Hayashi, Kei [1 ]
Garcia, Tanya C. [1 ]
Kim, Sun-Young [1 ]
Entwistle, Rachel [1 ]
Kapatkin, Amy S. [1 ]
Stover, Susan M. [1 ]
机构
[1] Univ Calif Davis, Sch Vet Med, Dept Surg & Radiol Sci, JD Wheat Vet Orthoped Res Lab, Davis, CA 95616 USA
关键词
STRAIN DISTRIBUTION; HINDLIMB LAMENESS; GAIT ANALYSIS; CANINE FEMUR; CANAL FILL; DOGS; REPLACEMENT; FORCES; ARTHROPLASTY; PROSTHESIS;
D O I
10.1111/j.1532-950X.2011.00890.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective: To compare (1) proximal femoral axial strains, (2) femoral head deflection, and (3) failure mechanical properties, between Helica head and neck prosthesis implanted femora and normal femora. Study Design: In vitro study. Sample Population: Cadaveric canine femora (n = 5 pair). Methods: Femoral bone strains and head displacement during in vitro simulation of midstance of the gallop were evaluated using cadaveric femurs cyclically loaded in vitro. Strains and displacements were compared within femurs, before and after, prosthesis implantation; and throughout cycling to seek evidence of movement with cyclic loading. Subsequently, implanted femurs and contralateral, intact femurs were loaded to failure to compare failure mechanical properties and modes of failure. Results: Proximal femoral axial strains were significantly different between intact and implanted femora on all 4 cortical surfaces (P < .05). Compressive strains were lower in the implanted femur on all cortical surfaces, except on the caudal surface which was higher. No difference was noted for femoral head angle under an axial load corresponding to gallop (P > .05). Vertical head displacement was similar to 0.1 mm greater for implanted femora than intact femora (P < .05). Yield and failure loads and yield energy of implanted femora were 39-54% lower than those for intact femora (P < .05). Mode of failure for both the intact and implanted femora did not appear to be different. Conclusion: Helica femoral prosthesis alters strain distribution in the proximal aspect of the femur and exhibits initial micromotion. Failure load in axial compression of the Helica-implanted femur is less than that of the normal femur, but greater than that expected in vivo.
引用
收藏
页码:94 / 102
页数:9
相关论文
共 50 条
  • [21] Cementless Tapered Femoral Stems for Total Hip Arthroplasty in Octogenarians
    Riley, Stephanie A.
    Spears, James R.
    Smith, Langan S.
    Mont, Michael A.
    Elmallah, Randa K.
    Cherian, Jeffrey J.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12): : 2810 - 2813
  • [22] Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study
    Perez Neto, Daniel M. G.
    Muzzi, Leonardo A. L.
    Santos, Fabio L.
    Muzzi, Ruthnea A. L.
    Kawamoto, Fernando Y. K.
    Mesquita, Luciane R.
    Minto, Bruno W.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024,
  • [23] Total hip arthroplasty with the cementless spiron femoral neck prosthesis
    Lugeder, A.
    Haering, E.
    Mueller, A.
    Droste, P.
    Zeichen, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2013, 25 (04): : 388 - 397
  • [24] Tapered design for the cementless total hip arthroplasty femoral component
    Mallory, TH
    Head, WC
    Lombardi, AV
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (344) : 172 - 178
  • [25] Revision Total Hip Arthroplasty With a Modular Cementless Femoral Stem
    Pelt, Christoper E.
    Madsen, Wes
    Erickson, Jill A.
    Gililland, Jeremy M.
    Anderson, Mike B.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1803 - 1807
  • [26] Isoelastic femoral component in primary cementless total hip arthroplasty
    Salaman M. Ali
    A. Kumar
    International Orthopaedics, 2002, 26 : 243 - 246
  • [27] Isoelastic femoral component in primary cementless total hip arthroplasty
    Ali, MS
    Kumar, A
    INTERNATIONAL ORTHOPAEDICS, 2002, 26 (04) : 243 - 246
  • [28] Osteonecrosis of the femoral head treated with cementless total hip arthroplasty
    Hartley, WT
    McAuley, JP
    Culpepper, WJ
    Engh, CA
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10): : 1408 - 1413
  • [29] Intraoperative complications in total hip arthroplasty using a new cementless femoral implant (SP-CL(R))
    Tootsi, Kaspar
    Lees, Loviisa
    Geiko, Boris
    Martson, Aare
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 21 (01)
  • [30] Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation
    Windolf, Mafkus
    Braunstein, Volker
    Dutoit, Christof
    Schwieger, Karsten
    CLINICAL BIOMECHANICS, 2009, 24 (01) : 59 - 64