Adaptive non-rigid registration of 3D knee MRI in different pose spaces

被引:3
|
作者
Rheel, Taehyun [1 ]
Lewis, J. P. [3 ]
Nayak, Krishna [2 ]
Neumann, Ulrich [1 ]
机构
[1] Univ Southern Calif, Dept Comp Sci, Los Angeles, CA 90089 USA
[2] Univ Southern Calif, Dept Elect Engn, Los Angeles, CA USA
[3] Weta Digital, Wellington, New Zealand
关键词
adaptive registration; non-rigid registration; articulation; volume deformation; MRI;
D O I
10.1109/ISBI.2008.4541195
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Volume registration of articulated subjects such as the human knee region requires novel methods to accommodate the wide range of movement resulting from skeletal joint rotations. This paper addresses articulated volume deformation with a pair of techniques. Volume skeletal deformation (VSD) is applied first, producing a smooth but approximate deformation of the soft tissue as the underlying skeleton moves, while preserving rigid motion in the segmented bone regions. The resulting deformed volume is used as initialization for a non-rigid deformation step that locally and adaptively adds radial basis function control points to minimize the remaining registration error in any poorly aligned region. The resulting process registers a neutral pose volume to any given bent-knee pose MRI scan.
引用
收藏
页码:1111 / +
页数:2
相关论文
共 50 条
  • [31] 2D/3D Non-rigid Image Registration by an Efficient Demons Approach
    Mishra, Ashutosh
    Mondal, Pulak
    Banerjee, Swapna
    2014 IEEE 27TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2014, : 481 - 482
  • [32] Non-Rigid Registration of 3D Surfaces by Deformable 2D Triangular Meshes
    Savran, Arman
    Sankur, Buelent
    2008 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, VOLS 1-3, 2008, : 985 - 990
  • [33] Non-rigid registration of intraoperatively acquired 3D ultrasound data of brain tumors
    Letteboer, MMJ
    Hellier, P
    Rueckert, D
    Willems, PWA
    Berkelbach, JW
    Niessen, WJ
    PERSPECTIVE IN IMAGE-GUIDED SURGERY, 2004, : 11 - 18
  • [34] 3D non-rigid registration using color: Color Coherent Point Drift
    Saval-Calvo, Marcelo
    Azorin-Lopez, Jorge
    Fuster-Guillo, Andres
    Villena-Martinez, Victor
    Fisher, Robert B.
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2018, 169 : 119 - 135
  • [35] LBM craniocerebral MR 3D medical image non-rigid registration method
    Zheng, X. (zhx_xdu@163.com), 1600, Science Press (40):
  • [36] Spatiotemporal non-rigid image registration for 3D ultrasound cardiac motion estimation
    Loeckx, D.
    Ector, J.
    Maes, F.
    D'hooge, J.
    Vandermeulen, D.
    Voigt, J-U
    Heidbuechel, H.
    Suetens, P.
    MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
  • [37] Non-rigid registration of serial section images by blending transforms for 3D reconstruction
    Kajihara, Takehiro
    Funatomi, Takuya
    Makishima, Haruyuki
    Aoto, Takahito
    Kubo, Hiroyuki
    Yamada, Shigehito
    Mukaigawa, Yasuhiro
    PATTERN RECOGNITION, 2019, 96
  • [38] Spatio-Temporal Non-Rigid Registration of 3D Point Clouds of Plants
    Chebrolu, Nived
    Labe, Thomas
    Stachniss, Cyrill
    2020 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2020, : 3112 - 3118
  • [39] Understanding the "Demon's Algorithm": 3D non-rigid registration by gradient descent
    Pennec, X
    Cachier, P
    Ayache, N
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 597 - 605
  • [40] Non-rigid registration of 3D ultrasound images to monitor carotid plaque changes
    Nanayakkara, N. D.
    Chiu, B.
    Samani, A.
    Spence, J. D.
    Samarabandu, J.
    Fenster, A.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S77 - S77