Readout ASIC for 3D position-sensitive detectors

被引:35
|
作者
de Geronimo, Gianluigi [1 ]
Vernon, Emerson [1 ]
Ackley, Kim [1 ]
Dragone, Angelo [2 ]
Fried, Jack [1 ]
O'Connor, Paul [1 ]
He, Zhong [3 ]
Herman, Cedric
Zhang, Feng [3 ]
机构
[1] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
[2] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
[3] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
关键词
application specific integrated circuit (ASIC); Cadmium-Zinc-Telluride (CZT); 3D; timing;
D O I
10.1109/TNS.2008.922217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe an application specific integrated circuit (ASIC) for 3D position-sensitive detectors. It was optimized for pixelated Cadmium-Zinc-Telluride (CZT) sensors, and it measures, corresponding to an ionizing event, the energy and timing of signals from 121 anodes and one cathode. Each channel provides low-noise charge amplification, high-order shaping, along with peak- and timing-detection. The cathode's timing can be measured in three different ways: the first is based on multiple thresholds on the charge amplifier's voltage output; the second uses the threshold crossing of a fast-shaped signal; and the third measures the peak amplitude and timing from a bipolar shaper. With its power of 2 mW per channel the ASIC measures, on a CZT sensor connected and biased, charges up to 100 fC with an electronic resolution better than 200 e(-) rms. Our preliminary spectral measurements applying a simple cathode/anode ratio correction demonstrated a single-pixel resolution of 4.8 keV (0.72 %) at 662 keV, with the electronics and leakage current contributing in total with 2.1 keV.
引用
收藏
页码:1593 / 1603
页数:11
相关论文
共 50 条
  • [21] POSITION-SENSITIVE GERMANIUM DETECTORS
    PROTIC, D
    RIEPE, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 553 - 555
  • [22] POSITION-SENSITIVE SCINTILLATION DETECTORS
    ROGERS, EH
    ARENS, JF
    WHITESIDE, H
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 599 - 604
  • [23] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS
    RADEKA, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01): : 209 - 218
  • [24] Performance evaluation of position-sensitive silicon detectors with four-corner readout
    Banu, A.
    Li, Y.
    McCleskey, M.
    Bullough, M.
    Walsh, S.
    Gagliardi, C. A.
    Trache, L.
    Tribble, R. E.
    Wilburn, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 593 (03): : 399 - 406
  • [25] Characterization of the H3D ASIC Readout System and 6.0 cm3 3-D Position Sensitive CdZnTe Detectors
    Zhang, Feng
    Herman, Cedric
    He, Zhong
    De Geronimo, Gianluigi
    Vernon, Emerson
    Fried, Jack
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 236 - 242
  • [26] Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors
    Campana, R.
    Evangelista, Y.
    Fuschino, F.
    Ahangarianabhari, M.
    Macera, D.
    Bertuccio, G.
    Grassi, M.
    Labanti, C.
    Marisaldi, M.
    Malcovati, P.
    Rachevski, A.
    Zampa, G.
    Zampa, N.
    Andreani, L.
    Baldazzi, G.
    Del Monte, E.
    Favre, Y.
    Feroci, M.
    Muleri, F.
    Rashevskaya, I.
    Vacchi, A.
    Ficorella, F.
    Giacomini, G.
    Picciotto, A.
    Zuffa, M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [27] A front end readout electronics ASIC chip for position sensitive solid state detectors
    Kravis, SD
    Tumer, TO
    Visser, GJ
    Maeding, DG
    Yin, S
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 579 - 584
  • [28] POSITION-SENSITIVE GAMMA-RAY DETECTORS USING RESISTIVE CHARGE DIVISION READOUT
    GERBER, MS
    MILLER, DW
    SCHLOSSER, PA
    STEIDLEY, JW
    DEUTCHMAN, AH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 182 - 187
  • [29] A QTC-based signal readout for position-sensitive multi-output detectors
    Wei Zhou
    Zhi-Ming Zhang
    Dao-Wu Li
    Pei-Lin Wang
    Bao-Tong Feng
    Xian-Chao Huang
    Ting-Ting Hu
    Xiao-Hui Li
    Yan Chen
    Ying-Jie Wang
    Yan-Tao Liu
    Yi-Wen Zhang
    Shi-Feng Sun
    Xiao-Yue Gu
    Ming-Jie Yang
    Xiong Xiao
    Long Wei
    Nuclear Science and Techniques, 2016, 27 (05) : 73 - 79
  • [30] Readout electronics for position-sensitive gas filled detectors at the European Synchrotron Radiation Facility
    Hervé, C
    Le Caër, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 226 - 231