A Study on Improving Economy Efficiency of Pumping Stations Based on Tariff Changes

被引:2
|
作者
Napierala, Michal [1 ]
机构
[1] Poznan Univ Life Sci, Dept Land Improvement Environm Dev & Spatial Mana, Piatkowska 94E, PL-60649 Poznan, Poland
关键词
pumping stations; energy tariff; economic efficiency; WATER DISTRIBUTION-SYSTEMS; OPTIMAL OPERATION; OPTIMIZATION; MODEL;
D O I
10.3390/en15030799
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, research on improving the economic efficiency of 38 drainage pumping stations was undertaken. Particular attention was paid to the effectiveness of activities without considering any expenditures. Energy costs for this type of machine are usually high, approximately 45% of the total maintenance cost. The main assumption of this work was the selection of appropriate energy tariffs to reduce operating costs. Liquid transport in any economy consumes significant amounts of electricity, estimated at 20-30% of the total electricity production. The optimization of the energy consumption of pumping processes is, therefore, very important. While analyzing the choice of energy tariffs, we designed profitability ratios (PR) specifically for different daily time zones. With the forecasted distribution of energy demands for different daily time zones (usually 2 or 3 zones), it was possible to compare multi-zone tariffs with 24 h tariffs. The profitability of the tariffs was decided by the value of the PR indicator. The lower, the better. In practice, this meant that the analyzed multi-zone tariffs, in most cases, are more profitable compared to single-zone tariffs. In the Polish energy system, each entrepreneur, depending on the connection power, has a right to choose a particular energy tariff from three tariff groups, i.e., high (A), medium (B), and low (C) voltage. In the case of land reclamation pumping stations, energy tariffs are usually from groups B and C. The choice of tariffs largely depends on the contracted capacity and is determined by tariff regulation. Nowadays, the current energy system forces entrepreneurs to declare a connected power load at the level corresponding to the maximum use of the production potential. Lack of knowledge of the hydrological regime, quite common for land reclamation pumping stations, usually results in overestimating the contracted capacity. When comparing the effect of changing tariffs, it was found that the profitability of this method is significant. The four-year study period (2010-2013) showed that active energy in the multi-part tariffs of groups B and C is on average 10.2% cheaper than in the single-part tariffs and varies in a wide range from 2% to 20.4%. The analysis carried out on 38 drainage pumping stations shows that for only five pumping stations could changing the current tariff be unjustified. In the other cases, the four years of analysis demonstrates that changing the current energy tariff could reduce electricity costs by approximately 5%., i.e., approximately PLN 124,000 per year (approximately EUR 27,000).
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Monitoring the Operating Condition of Pipeline of Pumping Stations Based on Recurrence Theory
    Zhang J.
    Cheng M.
    Ma X.
    Wang L.
    Zhang Y.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2020, 40 (03): : 481 - 488
  • [42] IMPROVEMENT OF WATER PUMPING ENERGY EFFICIENCY IN URBAN HEATING STATIONS USING PUMP SPEED CONTROL
    Sarbu, Ioan
    Valea, Emilian Stefan
    ENERGY AND CLEAN TECHNOLOGIES, 2015, : 307 - 314
  • [43] INCREASE OF EFFICIENCY OF SYSTEMS OF PROTECTION OF THE EQUIPMENT OF OIL PUMPING STATIONS AGAINST THE RAISED WAVES OF PRESSURE
    Ledovskiy, G. N.
    Samolenkov, S. V.
    Kabanov, O. V.
    JOURNAL OF MINING INSTITUTE, 2013, 206 : 99 - 102
  • [44] INVESTMENT RECOVERY PERIOD IN HYDRAULIC PUMP OF BETTER EFFICIENCY IN PUMPING SYSTEMS IN THE GREEN HOURLY SEASONAL TARIFF FOR IRRIGATION
    Zocoler, Joao L.
    Hernandez, Fernando B. T.
    Saad, Joao C. C.
    Cruz, Raimundo L.
    ENGENHARIA AGRICOLA, 2011, 31 (02): : 290 - 302
  • [45] Distributed Optimization of Cascade Pumping Stations Based on State-based Potential Game
    Zhao, Yikang
    Xie, Gang
    Li, Rong
    Xu, Xinying
    ENGINEERING LETTERS, 2025, 33 (04) : 1035 - 1044
  • [46] Improving energy efficiency in operations: a practice-based study
    Taghavi, Naghmeh
    SUPPLY CHAIN FORUM, 2022, 23 (04): : 374 - 396
  • [47] THE STUDY OF SEASONAL CHANGES OF PERMANENT STATIONS COORDINATES BASED ON WEEKLY EPN SOLUTIONS
    Maciuk, Kamil
    ARTIFICIAL SATELLITES-JOURNAL OF PLANETARY GEODESY, 2016, 51 (01): : 1 - 18
  • [49] Establishing a national priority for improving energy efficiency in the US economy
    E-VISION 2002: SHAPING OUR ENERGY FUTURE, PROCEEDINGS: SHAPING OUR FUTURE BY REDUCING ENERGY INTENSITY IN THE U.S. ECONOMY, 2003, : 27 - 34
  • [50] Recommendations for improving the operation efficiency of electric pumping units of mine drainage installations
    Ovchinnikov, N. P.
    III INTERNATIONAL SCIENTIFIC CONFERENCE: AGRITECH-III-2020: AGRIBUSINESS, ENVIRONMENTAL ENGINEERING AND BIOTECHNOLOGIES, PTS 1-8, 2020, 548