Breakthrough in the lifetime of microchannel plate photomultipliers

被引:11
|
作者
Uhlig, F. [1 ]
Britting, A. [1 ]
Eyrich, W. [1 ]
Lehmann, A. [1 ]
Dzhygadlo, R. [1 ]
Gerhardt, A. [2 ]
Gotzen, K. [2 ]
Kalicy, G. [2 ]
Krebs, M. [2 ]
Kumawat, H. [2 ]
Lehmann, D. [2 ]
Patsyuk, M. [2 ]
Peters, K. [2 ]
Schepers, G. [2 ]
Schmitt, L. [2 ]
Schwarz, C. [2 ]
Schwiening, J. [2 ]
Traxler, M. [2 ]
Zuehlsdorf, M. [2 ]
Dodokhov, V. Kh. [3 ]
Dueren, M. [4 ]
Etzelmueller, E. [4 ]
Foehl, K. [4 ]
Hayrapetyan, A. [4 ]
Kroeck, B. [4 ]
Merle, O. [4 ]
Rieke, J. [4 ]
Cowie, E. [5 ]
Keri, T. [5 ]
Montgomery, R. [5 ]
Achenbach, P. [6 ]
Cardinali, M. [6 ]
Hoek, M. [6 ]
Lauth, W. [6 ]
Schlimme, S. [6 ]
Sfienti, C. [6 ]
Thiel, M. [6 ]
Buehler, P. [7 ]
Gruber, L. [7 ]
Marton, J. [7 ]
Suzuki, K. [7 ]
机构
[1] Univ Erlangen Nurnberg, D-91054 Erlangen, Germany
[2] GSI Helmholtzzentrum Schwerionenforsch GmbH, Darmstadt, Germany
[3] Joint Inst Nucl Res, Dubna, Russia
[4] Univ Giessen, Inst Phys 2, Giessen, Germany
[5] Univ Glasgow, Glasgow, Lanark, Scotland
[6] Johannes Gutenberg Univ Mainz, Inst Kernphys, Mainz, Germany
[7] Austrian Acad Sci, Stefan Meyer Inst Subatomare Phys, A-1010 Vienna, Austria
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2015年 / 787卷
关键词
(P)over-barANDA experiment; MCP-PMT; Photon detector; DIRC; Lifetime; ALD-coating;
D O I
10.1016/j.nima.2014.11.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cherenkov detectors using the DIRC (Detection of Internally Reflected Cherenkov Light) principle are foreseen for particle identification in the (P) over bar ANDA experiment at FAIR. Promising sensors for the detection of the Cherenkov light are the so-called micro-channel plate (MCP) photomultipliers (PMT). They have an excellent time resolution, can be operated at high gain for single photon detection and have a high resistivity against magnetic fields. The disadvantage of these devices was their limited lifetime, due to damage by feedback ions on the photocathode. The lifetime of various types of MCP-PMTs from different manufactures has been tested under conditions similar to that in the (P) over bar ANDA experiment. The sensors are assembled in one setup, to ensure the same illumination conditions. The measurement procedure requires permanent monitoring of the illumination and interruptions after about 2-3 weeks to measure dark count rate, gain and spectral quantum efficiency of all sensors. Furthermore surface scans of the whole photocathode are done every 2-4 months to determine faster aging areas. The latest results show very good lifetime performance for MCP-PMTs, where the MCPs have been treated with the atomic layer deposition (ALD) technique. (C) 2014 Elsevier B.V. All rights reserved,
引用
收藏
页码:105 / 109
页数:5
相关论文
共 50 条
  • [31] IMPROVING THE PERFORMANCE OF ULTRAFAST MICROCHANNEL-PLATE PHOTOMULTIPLIERS IN TIME-CORRELATED PHOTON-COUNTING BY PULSE PRESHAPING
    COVA, S
    RIPAMONTI, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (03): : 1072 - 1075
  • [32] Time-of-flight resolution of scintillating counters with Burle 85001 microchannel plate photomultipliers in comparison with Hamamatsu R2083
    Baturin, V.
    Burkert, V.
    Kim, W.
    Majewsky, S.
    Park, K.
    Popov, V.
    Smith, E. S.
    Son, D.
    Stepanyan, S. S.
    Zorn, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (01): : 327 - 337
  • [33] Small-pore microchannel plates forge ultrafast photomultipliers
    Howorth, Jon
    Milnes, James
    Jones, Gareth
    LASER FOCUS WORLD, 2012, 48 (03): : 48 - 51
  • [34] Evaluation of a microchannel-plate PMT as a potential timing detector suitable for positron lifetime measurements
    Kosev, K.
    Butterling, M.
    Anwand, W.
    Cowan, T.
    Hartmann, A.
    Heidel, K.
    Jungmann, M.
    Krause-Rehberg, R.
    Massarczyk, R.
    Schilling, K. D.
    Schwengner, R.
    Wagner, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (03): : 641 - 645
  • [35] ELECTRONICS FOR MICROCHANNEL PHOTOMULTIPLIERS IN THE LIDAR THOMSON SCATTERING DIAGNOSTIC ON JET
    BUNDGAARD, J
    HANSEN, KB
    WEISBERG, KV
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (10): : 3265 - 3269
  • [36] PHOTOMULTIPLIER WITH A MICROCHANNEL PLATE
    BERKOVSKII, AG
    VERETENNIKOV, AI
    GUSELNIKOV, VG
    ZHURAVLEVA, NV
    SATTAROV, DK
    FILIMONOVA, TA
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1980, 47 (02): : 78 - 79
  • [37] MICROCHANNEL PLATE DETECTORS
    WIZA, JL
    NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 587 - 601
  • [38] Determination of the timing properties of a pulsed positron lifetime beam by the application of an electron gun and a fast microchannel plate
    Laakso, A
    Pelli, A
    Rytsölä, K
    Saarinen, K
    Hautojärvi, P
    APPLIED SURFACE SCIENCE, 2006, 252 (09) : 3148 - 3153
  • [39] MICROCHANNEL PLATE LIFE TESTS
    SANDEL, BR
    BROADFOOT, AL
    SHEMANSKY, DE
    APPLIED OPTICS, 1977, 16 (05): : 1435 - 1437
  • [40] MICROCHANNEL PLATE STREAK CAMERA
    WANG, CL
    MEDECKI, H
    HALE, CP
    LEIPELT, GR
    THOMAS, SW
    WIEDWALD, JD
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 82 - 85