A Pixelated CsI(Tl) Scintillator for CMOS-based X-ray Image Sensor

被引:15
|
作者
Cha, Bo Kyung [1 ]
Kim, Byoung-Jik [1 ]
Cho, Gyuseong [1 ]
Jeon, Sung Chae [2 ]
Bae, Jun Hyung [1 ]
Chi, Yong Ki [1 ]
Lim, Gyu-Ho [3 ]
Kim, Young-Hee [3 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Taejon 305701, South Korea
[2] KERI, Elect Bio Sensor Res Grp, Seongju 426 901, South Korea
[3] Changwon Natl Univ, Dept Elect Engn, Chang Won, South Korea
关键词
D O I
10.1109/NSSMIC.2006.356046
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Direct and indirect imaging detectors for digital radiography have been developed during the past a few years. Among scintillators, columnar CsI(Tl) screens are used for indirect digital X-ray imaging for industrial and medical radiography. By the help of recent developments CMOS (Complementary Metal Oxide Semiconductor) is replacing the CCD (Charge Coupled Devices) in X-ray image sensor because of low operating power, standard CMOS manufacturing process, and low cost. An X-ray imaging detector consisting of pixelated CsI(Tl) scintillator and CMOS imaging sensor for application in dental radiography was developed. The manufactured CMOS imaging sensor has 128 by 128 pixels with the pitch size of 50 mu m and gap width of 5 mu m. A 0.5 mu m CMOS process was used for sensor fabrication. Pixel structured CsI(Tl) scintillator was directly deposited on the patterned CMOS imaging sensor by thermal evaporation and photo-lithography process. The fabricated monolithic X-ray imaging sensor showed dramatic improvement in spatial resolution due to enhancement of the scintillation light guiding effect and reduction of the light cross-talk between scintillator pixels.
引用
收藏
页码:1139 / 1143
页数:5
相关论文
共 50 条
  • [31] Structured CsI(Tl) scintillators for X-ray imaging applications
    Nagarkar, VV
    Gupta, TK
    Miller, SR
    Klugerman, Y
    Squillante, MR
    Entine, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 492 - 496
  • [32] SPECTRAL CHARACTERISTICS OF CSI-TL X-RAY LUMINOPHOR
    SMOLSKAYA, LP
    KOLESNIKOVA, TA
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1977, 41 (07): : 1409 - 1412
  • [33] Structured CsI(Tl) scintillators for x-ray imaging applications
    Radiation Monitoring Devices, Inc, Watertown, United States
    IEEE Trans Nucl Sci, 3 pt 1 (492-496):
  • [34] Structured CsI(Tl) scintillators for X-ray imaging applications
    Nagarkar, VV
    Gupta, TK
    Miller, S
    Klugarman, Y
    Squillante, MR
    Entine, G
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 226 - 230
  • [35] Portal CT reconstruction using the CsI(Tl) transparent scintillator x-ray detector and the MLS-ART technique
    Guan, HQ
    Zhu, YP
    Gaber, MW
    Sawant, A
    Zeman, H
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 215 - 222
  • [36] Pixelated Columnar CsI:Tl Scintillator for High Resolution Radiography and Cone-Beam CT
    Miller, Stuart R.
    Singh, Bipin
    Marshall, Matthew S. J.
    Brown, Conner
    Sheth, Niral
    Shi, Gengxin
    Siewerdsen, Jeffrey H.
    Zbijewski, Wojciech
    Nagarkar, Vivek V.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [37] Investigating the image lag of a scientific CMOS sensor in X-ray detection
    Wu, Qinyu
    Ling, Zhixing
    Zhang, Chen
    Zhou, Quan
    Wang, Xinyang
    Yuan, Weimin
    Zhang, Shuang-Nan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1050
  • [38] Ionising radiation effects in a soft X-ray CMOS image sensor
    Townsend-Rose, Charles
    Buggey, Thomas
    Ivory, James
    Stefanov, Konstantin D.
    Holland, Andrew D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1059
  • [39] CMOS x-ray image sensor with pixel level A/D conversion
    Rocha, JG
    Ramos, NF
    Wolffenbuttel, RF
    Correia, JH
    ESSCIRC 2003: PROCEEDINGS OF THE 29TH EUROPEAN SOLID-STATE CIRCUITS CONFERENCE, 2003, : 121 - 124
  • [40] Contrast-detail analysis of a CMOS-based digital x-ray imaging system
    Zhang, QR
    Li, YH
    Steele, B
    Chen, WR
    Wu, XZ
    Cheung, J
    Liu, H
    COMPUTERS AND THEIR APPLICATIONS, 2004, : 51 - 54