The FRED Flow-Diverter Stent for Intracranial Aneurysms: Clinical Study to Assess Safety and Efficacy

被引:91
|
作者
Moehlenbruch, M. A. [1 ]
Herweh, C. [1 ]
Jestaedt, L. [1 ]
Stampfl, S. [1 ]
Schoenenberger, S. [2 ]
Ringleb, P. A. [2 ]
Bendszus, M. [1 ]
Pham, M. [1 ]
机构
[1] Heidelberg Univ, Med Ctr, Dept Neuroradiol, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Med Ctr, Dept Neurol, D-69120 Heidelberg, Germany
关键词
PIPELINE EMBOLIZATION DEVICE; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; COILING;
D O I
10.3174/ajnr.A4251
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Flow-diverter stents are emerging for the endovascular treatment of difficult-to-treat or otherwise untreatable cerebral aneurysms (wide-neck, fusiform, dissecting, blisterlike, or giant). We assessed the clinical safety and efficacy of the Flow-Redirection Endoluminal Device. MATERIALS AND METHODS: This was an institutional review board-approved single-center observational clinical study in 29 patients with 34 aneurysms elected to be treated by endovascular intervention. After providing informed consent, patients were included according to the following criteria: aneurysm fundus-to-neck ratio <2 or neck diameter >4 mm, fusiform, dissecting, or giant aneurysms. The primary end point for clinical safety was the absence of death, absence of major or minor stroke, and absence of transient ischemic attack. The primary end point for treatment efficacy was complete angiographic occlusion according to the O'Kelly Marotta grading scale immediately after the procedure and at follow-up after 3 and 6 months (O'Kelly Marotta D: complete occlusion). RESULTS: The Flow-Redirection Intraluminal Device deployment was technically successful in all cases. In 26/29 (89%) of patients, the primary end point of safety was reached; in the 3 remaining patients, 1 disabling ischemic stroke and 2 minor strokes with complete recovery at follow-up were observed. Angiographic (DSA and MRA) and clinical follow-up were available after 3 months in 29/29 (100%) and after 6 months in 25/29 (86%) patients (after 6 months, only MRA follow-up was performed according to our study protocol and institutional standard). At 3-month follow-up, complete occlusion was reached in 19/34 aneurysms (O'Kelly Marotta D: 19/34; 56%). At 6-month follow-up, aneurysm occlusion was complete in 22/30 aneurysms (O'Kelly Marotta D: 22/30; 73%). CONCLUSIONS: Deployment of the Flow-Redirection Intraluminal Device flow-diverter stent is safe and effective in the treatment of difficult-to-treat or otherwise untreatable intracranial aneurysms.
引用
收藏
页码:1155 / 1161
页数:7
相关论文
共 50 条
  • [21] Usefulness of Silent MR Angiography for Intracranial Aneurysms Treated with a Flow-Diverter Device
    Oishi, H.
    Fujii, T.
    Suzuki, M.
    Takano, N.
    Teranishi, K.
    Yatomi, K.
    Kitamura, T.
    Yamamoto, M.
    Aoki, S.
    Arai, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : 808 - 814
  • [22] Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
    Arrese, Ignacio
    Sarabia, Rosario
    Pintado, Rebeca
    Delgado-Rodriguez, Miguel
    NEUROSURGERY, 2013, 73 (02) : 193 - 199
  • [23] CFD Study on the Efficacy of Flow Diverter Stent Placement for Cerebral Aneurysms
    Ito, Y.
    Cho, I
    Sakai, Y.
    Iwano, K.
    JOURNAL OF APPLIED FLUID MECHANICS, 2021, 14 (05) : 1547 - 1558
  • [24] Silk Flow-Diverter Stent for the Treatment of Intracranial Aneurysms: A Series of 58 Patients with Emphasis on Long-Term Results
    Lubicz, B.
    Van der Elst, O.
    Collignon, L.
    Mine, B.
    Alghamdi, F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 542 - 546
  • [25] Cerebral Revascularization for Aneurysms in the Flow-Diverter Era
    Straus, David C.
    da Silva, Harley Brito
    McGrath, Lynn
    Levitt, Michael R.
    Kim, Louis J.
    Ghodke, Basavaraj V.
    Barber, Jason K.
    Sekhar, Laligam N.
    NEUROSURGERY, 2017, 80 (05) : 759 - 767
  • [26] FRED Flow Diverter: A Study on Safety and Efficacy in a Consecutive Group of 50 Patients
    Luecking, H.
    Engelhorn, T.
    Lang, S.
    Goelitz, P.
    Kloska, S.
    Roessler, K.
    Doerfler, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (03) : 596 - 602
  • [27] Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis COMMENTS
    Briganti, Francesco
    Raymond, Jean
    Darsaut, Tim E.
    Byrne, James
    NEUROSURGERY, 2013, 73 (02) : 199 - 200
  • [28] Parametric study of porous media as substitutes for flow-diverter stent
    Ohta, Makoto
    Anzai, Hitomi
    Miura, Yukihisa
    Nakayama, Toshio
    BIOMATERIALS AND BIOMECHANICS IN BIOENGINEERING, 2015, 2 (02): : 111 - 125
  • [29] Safety and efficacy of staged coiling followed by flow diverter in the treatment of ruptured intracranial aneurysms
    Li, Yuanzhi
    Fan, Feng
    Chen, Zhen
    Ma, Yajing
    Zhang, Hang
    Liu, Chao
    Fu, Yu
    Guan, Sheng
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [30] Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review
    Lv, Xianli
    Yang, Hongchao
    Liu, Peng
    Li, Youxiang
    NEURORADIOLOGY JOURNAL, 2016, 29 (01): : 66 - 71