A Piezoelectric Goniometer Inside a Transmission Electron Microscope Goniometer

被引:3
|
作者
Guan, Wei [1 ]
Lockwood, Aiden [1 ]
Inkson, Beverley J. [1 ]
Moebus, Guenter [1 ]
机构
[1] Univ Sheffield, Dept Mat Sci & Engn, NanoLAB Ctr, Sheffield S1 3JD, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
in situ TEM; electron tomography; nanomanipulation; piezo drive; SCANNING TUNNELING MICROSCOPE; IN-SITU NANOINDENTATION; TOMOGRAPHY; HOLDER;
D O I
10.1017/S143192761100050X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Piezoelectric nanoactuators, which can provide extremely stable and reproducible positioning, are rapidly becoming the dominant means for position control in transmission electron microscopy. Here we present a second-generation miniature goniometric nanomanipulation system, which is fully piezo-actuated with ultrafine step size for translation and rotation, programmable, and can be fitted inside a hollowed standard specimen holder for a transmission electron microscope (TEM). The movement range of this miniaturized drive is composed of seven degrees of freedom: three fine translational movements (X, Y, and Z axes), three coarse translational movements along all three axes, and one rotational movement around the X-axis with an integrated angular sensor providing absolute rotation feedback. The new piezoelectric system independently operates as a goniometer inside the TEM goniometer. In situ experiments, such as tomographic tilt without missing wedge and differential tilt between two specimens, are demonstrated.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 50 条
  • [41] A GONIOMETER DESIGNED FOR THE HAND
    NOER, HR
    PRATT, DR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1958, 40 (05): : 1154 - 1156
  • [42] Goniometer based to computer
    Barreiro, MS
    Frère, AF
    Theodório, NEM
    Amate, FC
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3290 - 3293
  • [43] OPTICOELECTRONIC DIFFERENTIAL GONIOMETER
    SOLDATOV, VP
    SOLOMATIN, VA
    YAKUSHENKOV, YG
    MEASUREMENT TECHNIQUES, 1978, 21 (03) : 339 - 340
  • [44] ELECTROMAGNETIC GONIOMETER FOR EPR
    WEIL, JA
    CLARIDGE, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1970, 41 (01): : 140 - &
  • [45] MEASUREMENTS BY GUESS AND BY GONIOMETER
    HOWES, RH
    ISDALE, LC
    AUSTRALASIAN ANNALS OF MEDICINE, 1969, 18 (02): : 181 - &
  • [46] TRANSMISSION GRATING GONIOMETER ELEMENTS FOR USE AT SYNCHROTRON RADIATION FACILITIES
    TATCHYN, R
    LINDAU, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 419 - 422
  • [47] DESIGN FOR A GONIOMETER HEAD
    DAVIES, DA
    MATHIESON, AM
    ACTA CRYSTALLOGRAPHICA, 1965, 18 : 871 - +
  • [48] AN IMPROVED GONIOMETER FOR ARTHROMETRY
    WAINERDI, HR
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1952, 149 (07): : 661 - 662
  • [49] A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion
    Rome, K
    Cowieson, F
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (01) : 28 - 32
  • [50] Flexible field goniometer system: the Goniometer for Outdoor Portable Hyperspectral Earth Reflectance
    Bachmann, Charles M.
    Abelev, Andrei
    Montes, Marcos J.
    Philpot, William
    Gray, Deric
    Doctor, Katarina Z.
    Fusina, Robert A.
    Mattis, Gordon
    Chen, Wei
    Noble, Scott D.
    Coburn, Craig
    Corl, Tom
    Slomer, Lawrence
    Nichols, C. Reid
    van Roggen, Elena
    Hughes, Roy J.
    Carr, Stephen
    Kharabash, Sergey
    Brady, Andrew
    Vermillion, Michael
    JOURNAL OF APPLIED REMOTE SENSING, 2016, 10