Mathematical modeling and cascade design of hollow fiber membrane contactor for CO2 absorption by monoethanolamine

被引:59
|
作者
Boributh, Somnuk [1 ]
Rongwong, Wichitpan [1 ]
Assabumrungrat, Suttichai [2 ]
Laosiripojana, Navadol [3 ]
Jiraratananon, Ratana [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Dept Chem Engn, Bangkok 10140, Thailand
[2] Chulalongkorn Univ, Dept Chem Engn, Fac Engn, Bangkok 10330, Thailand
[3] King Mongkuts Univ Technol Thonburi, Joint Grad Sch Energy & Environm, Bangkok 10140, Thailand
关键词
Carbon dioxide; Cascade design; Membrane contactor; Membrane wetting; MASS-TRANSFER; CARBON-DIOXIDE; GAS; RESISTANCE; REMOVAL;
D O I
10.1016/j.memsci.2012.01.048
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The absorption of CO2 from the gas mixture (CO2-CH4) by polyvinylidenefluoride (PVDF) hollow fiber membrane contactor using monoethanolamine (MEA) as the absorbent was performed. The mathematical model has been developed to predict the absorption performance. The model is validated with the experimental results for estimating the wetting ratio (x*) as the function of liquid velocity and MEA concentration. The suitable hollow fiber membrane module with effective fiber length of 50 cm is selected for the design of multistage membrane contactors. The absorption flux of multistage membrane contactor is simulated based on the value of x* obtained from the experiments. The three-stage cascade design is selected to compare the system performance with different gas and liquid flow patterns. The results of the simulation show that the individual gas flow (G-ID) gives higher performance compared to the gas flow in series (G-IS) for all operating conditions studied. The three different flow patterns of liquid including (i) liquid flow in series (L-IS), (ii) liquid flow in series with splitting (L-ISS) and (iii) liquid flow in series with recycle (L-ISR) are compared. At low MEA concentration (0.25 M), the L-ISR can improve the system performance at low liquid velocities, while L-ISS shows the highest performance at high liquid velocities. For the system with high MEA concentration (1.0 M), L-ISR can improve the performance at low to moderate liquid velocities, whereas L-ISS does not improve the system performance at any liquid velocity. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 189
页数:15
相关论文
共 50 条
  • [41] Effect of different additives on the physical and chemical CO2 absorption in polyetherimide hollow fiber membrane contactor system
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Rana, D.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 98 : 472 - 480
  • [42] Hollow fiber membrane contactor based CO2 absorption-stripping using novel solvents and membranes
    Kosaraju, P
    Kovvali, AS
    Korikov, A
    Sirkar, KK
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (05) : 1250 - 1258
  • [43] Effect of operating conditions on the physical and chemical CO2 absorption through the PVDF hollow fiber membrane contactor
    Mansourizadeh, A.
    Ismail, A. F.
    Matsuura, T.
    JOURNAL OF MEMBRANE SCIENCE, 2010, 353 (1-2) : 192 - 200
  • [44] Enhancing CO2 absorption efficiency using a novel PTFE hollow fiber membrane contactor at elevated pressure
    Wang, Fushan
    Kang, Guodong
    Liu, Dandan
    Li, Meng
    Cao, Yiming
    AICHE JOURNAL, 2018, 64 (06) : 2135 - 2145
  • [45] CO2 Stripping from Monoethanolamine through a Polypropylene/CH3SiO2 Composite Hollow-Fiber Membrane Contactor
    Amirabedi, Parya
    Akbari, Ali
    Yegani, Reza
    Raveshiyan, Saba
    CHEMICAL ENGINEERING & TECHNOLOGY, 2022, 45 (08) : 1512 - 1521
  • [46] Mathematical modeling for the simultaneous absorption of CO2 and H2S using MEA in hollow fiber membrane contactors
    Faiz, Rami
    Al-Marzouqi, M.
    JOURNAL OF MEMBRANE SCIENCE, 2009, 342 (1-2) : 269 - 278
  • [47] PVDF/CaCO3 composite hollow fiber membrane for CO2 absorption in gas-liquid membrane contactor
    Fosi-Kofal, M.
    Mustafa, A.
    Ismail, A. F.
    Rezaei-DashtArzhandi, M.
    Matsuura, T.
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 31 : 428 - 436
  • [48] Modeling and simulation of CO2 removal in a polyvinylidene fluoride hollow fiber membrane contactor with computational fluid dynamics
    Farjami, Marzie
    Moghadassi, Abdolreza
    Vatanpour, Vahid
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2015, 98 : 41 - 51
  • [49] CFD modeling of CO2 capture by water-based nanofluids using hollow fiber membrane contactor
    Hajilary, Nasibeh
    Rezakazemi, Mashallah
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 77 : 88 - 95
  • [50] HOLLOW FIBER MEMBRANE ABSORPTION OF CO2 IN THE FLUE GAS
    Yan Yunfei
    Zhang Zhien
    Zhang Li
    Ju Shunxiang
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,