Indoor Carbon Dioxide, Fine Particulate Matter and Total Volatile Organic Compounds in Private Healthcare and Elderly Care Facilities

被引:24
|
作者
Baudet, Alexandre [1 ,2 ]
Baures, Estelle [3 ]
Blanchard, Olivier [3 ]
Le Cann, Pierre [3 ]
Gangneux, Jean-Pierre [3 ,4 ]
Florentin, Arnaud [2 ,5 ]
机构
[1] Univ Lorraine, Fac Odontol, CHRU Nancy, F-54505 Vandoeuvre Les Nancy, France
[2] Univ Lorraine, APEMAC, F-54000 Nancy, France
[3] Univ Rennes, EHESP Sch Publ Hlth, IRSET Inst Rech Sante Environm & Travail UMR S 10, INSERM, F-35000 Rennes, France
[4] CHU Rennes, Lab Parasitol Mycol, F-35000 Rennes, France
[5] Univ Lorraine, Fac Med, CHRU Nancy, F-54505 Vandoeuvre Les Nancy, France
关键词
indoor air quality; carbon dioxide; particulate matter; total volatile organic compounds; dental offices; general practitioner offices; pharmacies; nursing homes; AIR-QUALITY; VENTILATION; AREAS; HOMES; RISK;
D O I
10.3390/toxics10030136
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Poor indoor air quality can have adverse effects on human health, especially in susceptible populations. The aim of this study was to measure the concentrations of dioxide carbon (CO2), fine particulate matter (PM2.5) and total volatile organic compounds (TVOCs) in situ in private healthcare and elderly care facilities. These pollutants were continuously measured in two rooms of six private healthcare facilities (general practitioner's offices, dental offices and pharmacies) and four elderly care facilities (nursing homes) in two French urban areas during two seasons: summer and winter. The mean CO2 concentrations ranged from 764 +/- 443 ppm in dental offices to 624 +/- 198 ppm in elderly care facilities. The mean PM2.5 concentrations ranged from 13.4 +/- 14.4 mu g/m(3) in dental offices to 5.7 +/- 4.8 mu g/m(3) in general practitioner offices. The mean TVOC concentrations ranged from 700 +/- 641 ppb in dental offices to 143 +/- 239 ppb in general practitioner offices. Dental offices presented higher levels of indoor air pollutants, associated with the dental activities. Increasing the ventilation of these facilities by opening a window is probably an appropriate method for reducing pollutant concentrations and maintaining good indoor air quality.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Response of Fine Particulate Matter to Emission Changes of Oxides of Nitrogen and-Anthropogenic Volatile Organic Compounds in the Eastern United States
    Tsimpidi, Alexandra P.
    Karydis, Vlassis A.
    Pandis, Spyros N.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (11): : 1463 - 1473
  • [32] Influence of indoor carbon dioxide and volatile organic compounds on building-related non-specific symptoms.
    Lu, C-Y
    Ma, Y-C
    Lin, J-M
    Sung, F-C
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2006, 163 (11) : S123 - S123
  • [33] Analysis of semi-volatile organic compounds in indoor suspended particulate matter by thermal desorption coupled with gas chromatography/mass spectrometry
    Mercier, Fabien
    Glorennec, Philippe
    Blanchard, Olivier
    Le Bot, Barbara
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1254 : 107 - 114
  • [34] Short-term exposure assessment to particulate matter and total volatile organic compounds in indoor air during cooking Ethiopian sauces (Wot) using electricity, kerosene and charcoal fuels
    Embiale, Asamene
    Zewge, Feleke
    Chandravanshi, Bhagwan Singh
    Sahle-Demessie, Endalkachew
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (08) : 1140 - 1154
  • [35] Sericin-coated polyester based air-filter for removal of particulate matter and volatile organic compounds (BTEX) from indoor air
    Verma, Vishal Kumar
    Subbiah, Senthilmurugan
    Kota, Sri Harsha
    CHEMOSPHERE, 2019, 237
  • [36] Predicting residential indoor concentrations of nitrogen dioxide, fine particulate matter, and elemental carbon using questionnaire and geographic information system based data
    Baxter, Lisa K.
    Clougherty, Jane E.
    Paciorek, Christopher J.
    Wright, Rosalind J.
    Levy, Jonathan I.
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (31) : 6561 - 6571
  • [37] Building-related respiratory symptoms prevalence among office employees and associations with indoor carbon dioxide and total volatile compounds concentration
    Chen, PC
    Lu, CY
    Ma, YC
    Lin, JM
    Sung, FC
    EPIDEMIOLOGY, 2005, 16 (05) : S42 - S43
  • [38] Improving indoor air quality through an air purifier able to reduce aerosol particulate matter (PM) and volatile organic compounds (VOCs): Experimental results
    Fermo, Paola
    Artinano, Begona
    De Gennaro, Gianluigi
    Pantaleo, Antonio Marco
    Parente, Alessandro
    Battaglia, Fiorella
    Colicino, Elena
    Di Tanna, Gianluca
    da Silva Junior, Andouglas Goncalves
    Pereira, Igor Gadelha
    Garcia, Gabriel Santos
    Goncalves, Luiz Marcos Garcia
    Comite, Valeria
    Miani, Alessandro
    ENVIRONMENTAL RESEARCH, 2021, 197
  • [39] Smoking in car: monitoring pollution of particulate matter, of organic volatile compounds and of carbon monoxide. The effect of opening the driver's window
    Invernizzi, Giovanni
    Ruprecht, Ario A.
    Mazza, Roberto
    De Marco, Cinzia
    Tagliapietra, Laura
    Michieletto, Federica
    Allegri, Francesca
    Sbrogio, Luca
    Boffi, Roberto
    EPIDEMIOLOGIA & PREVENZIONE, 2010, 34 (1-2): : 35 - 42
  • [40] In-vehicle exposure of carbon monoxide, nitrogen dioxide and total volatile organic compounds from ethanol versus gasoline fuel
    Alhajeri, N. S.
    Al-Fadhli, F. M.
    Alrukaibi, D. S.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (06) : 2707 - 2720