Determinants of aerosolized albuterol delivery to mechanically ventilated infants

被引:23
|
作者
Coleman, DM
Kelly, HW
McWilliams, BC
机构
[1] UNIV NEW MEXICO,HLTH SCI CTR,SCH MED,COLL PHARM,ALBUQUERQUE,NM 87131
[2] UNIV NEW MEXICO,HLTH SCI CTR,SCH MED,DEPT PEDIAT,ALBUQUERQUE,NM 87131
关键词
aerosol delivery; albuterol; infant; mechanical ventilation; metered-dose inhaler; nebulizer; spacer;
D O I
10.1378/chest.109.6.1607
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
An in vitro lung model and a volume ventilator were used to evaluate the delivery of aerosolized albuterol through an infant ventilator circuit, We compared the following: continuous nebulization (CNA) and intermittent nebulization (INA); various nebulizer gas flows, 5.0, 6.5, and 8.0 L/min; and duty cycle of 33% and 50%. The efficiency and consistency of aerosol delivery by metered-dose inhaler (MDI) with four different spacer devices and by nebulizer positioned at the manifold and at the same position as the MDI were also evaluated. A volume ventilator (Servo 900B) was used with settings selected to reflect those of a moderately to severely ill 4-kg infant. A 3.5-mm endotracheal tube,vas used in all experiments, A specific type of nebulizer used (Airlife Misty Neb; Baxter; Valencia, Calif) and several spacers were studied (Aerochamber and Aerovent, Diemolding Healthcare Div, Canastota, NY; ACE, Monaghan Medical Corp, Plattsburgh, NY; and an in-line MDI adapter, Instrumentation Industries Inc, Pittsburgh). CNA delivered significantly more aerosol to the lung model (4.8+/-0.6% of the starting dose) than INA (3.8+/-0.3%; p<0.01), There was a significant stepwise decrease in aerosol delivery with increasing nebulizer flow (4.8+/-1.3% at 5.0 L/min; 3.7+/-1.1% at 6.5 L/min; and 2.7+/-1.1% at 8.0 L/min). Increasing duty cycle did not significantly affect delivery. Overall the spacers with MDI were more efficient than the nebulizer in either position delivering about twice the percentage of the starting dose than the nebulizers. All modes of delivery, except the Aerochamber, demonstrated a marked degree of variability. Most of the starting dose of albuterol either remained in the nebulizer (30.4+/-6.0% at 5.0 L/min and 25.3+/-4.1% at 8.0 L/min) or was deposited in the inspiratory tubing (34.7+/-0.7% at 5.0 L/min and 43.7+/-4.9% at 8.0 L/min) in our system. In conclusion, we have confirmed that aerosol delivery depends on the mode of delivery and the operating conditions. Although delivery with an MDI and spacer is more efficient than a nebulizer, both methods may produce high variability depending on the method or spacer used.
引用
收藏
页码:1607 / 1613
页数:7
相关论文
共 50 条
  • [21] Ribavirin in mechanically ventilated infants
    Hubert, P
    ARCHIVES DE PEDIATRIE, 1996, 3 (02): : 186 - 186
  • [22] AEROSOLIZED RIBAVIRIN IN MECHANICALLY VENTILATED INFANTS WITH RESPIRATORY SYNCYTIAL VIRUS LOWER RESPIRATORY-TRACT DISEASE
    MEERT, K
    SARNAIK, A
    GELMINI, M
    LIEHLAI, M
    CLINICAL RESEARCH, 1993, 41 (03): : A652 - A652
  • [23] VEHICLE EFFECT ON VOLUME DELIVERY AND DRUG CONCENTRATION OF AEROSOLIZED ALBUTEROL
    HEMSTREET, MP
    SIMS, P
    CREEL, D
    INGRAM, M
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (01) : 335 - 335
  • [24] THE OUTCOME OF MECHANICALLY VENTILATED INFANTS AND CHILDREN
    BEJERSTEN, A
    OLSSON, GL
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1988, 5 (02): : 91 - 96
  • [25] DELIVERY OF AEROSOLIZED SURFACTANT TO PRETERM INFANTS
    Clark, Andrew R.
    MacLoughlin, Ronan J.
    Fink, James B.
    Asselin, Jeanette
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2019, 32 (03) : A24 - A25
  • [26] DESCRIPTION OF A DELIVERY METHOD FOR CONTINUOUSLY AEROSOLIZED ALBUTEROL IN STATUS-ASTHMATICUS
    VOSS, KR
    WILLSIEEDIGER, SK
    PYSZCZYNSKI, DR
    NELSON, KA
    JOURNAL OF ASTHMA, 1990, 27 (01) : 37 - 39
  • [27] OCCULT VOLUTRAUMA IN MECHANICALLY VENTILATED PRETERM INFANTS
    MEHROTRA, N
    SCHREIBER, MD
    COVERT, RF
    WYLAM, ME
    PEDIATRIC RESEARCH, 1995, 37 (04) : A342 - A342
  • [28] GASTROESOPHAGEAL REFLUX IN MECHANICALLY VENTILATED PRETERM INFANTS
    PRADEAUX, L
    BOGGIO, V
    GOUYON, JB
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1991, 66 (07): : 793 - 796
  • [29] RESPONSES TO MUSCLE PARALYSIS IN MECHANICALLY VENTILATED INFANTS
    STARK, AR
    BASCOM, R
    FRANTZ, ID
    PEDIATRIC RESEARCH, 1978, 12 (04) : 569 - 569
  • [30] SAFETY OF BRONCHOALVEOLAR LAVAGE IN MECHANICALLY VENTILATED INFANTS
    BELAI, I
    TAEUSCH, HW
    WALTHER, FJ
    PEDIATRIC RESEARCH, 1994, 35 (04) : A325 - A325