Aqueous size-exclusion chromatography of polyelectrolytes on reversed-phase and hydrophilic interaction chromatography columns

被引:9
|
作者
Caltabiano, Anna M. [1 ,2 ]
Foley, Joe P. [2 ]
Striegel, Andre M. [3 ]
机构
[1] GlaxoSmithKline, Analyt Sci & Dev, 1250 S Collegeville Rd, Collegeville, PA 19426 USA
[2] Drexel Univ, Dept Chem, 3141 Chestnut St, Philadelphia, PA 19104 USA
[3] NIST, Chem Sci Div, 100 Bur Dr,MS 8392, Gaithersburg, MD 20899 USA
关键词
Size-exclusion chromatography; SEC; Polymer; Sodium polystyrene sulfonate; Polyelectrolyte; NaPSS; SYNTHETIC-POLYMERS; CHALLENGES; DYNAMICS; WATER; MODEL;
D O I
10.1016/j.chroma.2017.12.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The size-exclusion separation of a water-soluble polyelectrolyte polymer, sodium polystyrene sulfonate (NaPSS), was demonstrated on common reversed-phase (C-18, C-4, phenyl, and cyano) and hydrophilic interaction chromatography (HILIC) columns. The effect of common solvents - acetonitrile (ACN), tetrahydrofuran (THF), and methanol (MeOH), used as mobile phase modifiers - on the elution of NaPSS and the effect of column temperature (within a relatively narrow range corresponding to typical chromatographic conditions, i.e., 10 degrees C-60 degrees C) on the partition coefficient, K-SEC, were also investigated. Non-size-exclusion chromatography (non-SEC) effects can be minimized by the addition of an electrolyte and an organic modifier to the mobile phase, and by increasing the column temperature (e.g., to 50 degrees C or 60 degrees C). Strong solvents such as THF and ACN are more successful in the reduction of such effects than is the weaker solvent MeOH. The best performance is seen on medium polarity and polar stationary phases, such as cyanopropyl- and diol-modified silica (HILIC), where the elution of the NaPSS polyelectrolyte is by a near-ideal SEC mechanism. Hydrophobic stationary phases, such as C-18, C-4, and phenyl, require a higher concentration of a strong solvent modifier (THF) in the mobile phase to reduce non-SEC interactions of the solute with the stationary phase. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 174
页数:14
相关论文
共 50 条
  • [31] Reversed-phase and size-exclusion chromatography as useful tools in the resolution of peroxidase-mediated (+)-catechin oxidation products
    López-Serrano, M
    Barceló, AR
    JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (02) : 267 - 273
  • [32] Fingerprint analysis of Ligusticum chuanxiong using hydrophilic interaction chromatography and reversed-phase liquid chromatography
    Jin, Yu
    Liang, Tu
    Fu, Qing
    Xiao, Yuan-Sheng
    Feng, Jia-Tao
    Ke, Yan-Xiong
    Liang, Xin-Miao
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (11) : 2136 - 2141
  • [33] Search for plant-induced technetium species with size-exclusion and reversed-phase ion-pair chromatography
    A. V. Harms
    J. T. van Elteren
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 228 : 139 - 146
  • [34] SIZE EXCLUSION CHROMATOGRAPHY OF POLYELECTROLYTES WITH AQUEOUS ELUTION SOLVENTS
    BRUESSAU, RJ
    MAKROMOLEKULARE CHEMIE-MACROMOLECULAR SYMPOSIA, 1992, 61 : 199 - 218
  • [35] SOLUTION PROPERTIES OF POLYELECTROLYTES .XI. ADSORPTION EFFECTS IN AQUEOUS SIZE-EXCLUSION CHROMATOGRAPHY OF POLYANIONS
    CAMPOS, A
    GARCIA, R
    PORCAR, I
    SORIA, V
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (14-15): : 3261 - 3283
  • [36] Polymethacrylate monolithic and hybrid particle-monolithic columns for reversed-phase and hydrophilic interaction capillary liquid chromatography
    Jandera, Pavel
    Urban, Jiri
    Skerikova, Veronika
    Langmaier, Pavel
    Kubickova, Romana
    Planeta, Josef
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (01) : 22 - 33
  • [37] AQUEOUS SIZE-EXCLUSION CHROMATOGRAPHY OF HYDROXYETHYL-AMYLOPECTIN
    SARAZIN, D
    FRANCOIS, J
    ROQUETA, C
    FLECHE, G
    CARBOHYDRATE POLYMERS, 1993, 21 (01) : 29 - 38
  • [38] Determination of the porosities of monolithic columns by inverse size-exclusion chromatography
    Al-Bokari, M
    Cherrak, D
    Guiochon, G
    JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (02) : 275 - 284
  • [39] ADSORPTIVE INTERACTION OF FICOLL STANDARDS WITH POROUS-GLASS SIZE-EXCLUSION CHROMATOGRAPHY COLUMNS
    SHAH, G
    DUBIN, PL
    JOURNAL OF CHROMATOGRAPHY A, 1995, 693 (02) : 197 - 203
  • [40] Hydrophilic interaction chromatography as an alternative to reversed-phase HPLC in determining anthocyanins and betacyanins
    Deineka, V.I.
    Saenko, I.I.
    Deineka, L.A.
    Blinova, I.P.
    Journal of Analytical Chemistry, 2016, 71 (03): : 297 - 301