Aqueous size-exclusion chromatography of polyelectrolytes on reversed-phase and hydrophilic interaction chromatography columns

被引:9
|
作者
Caltabiano, Anna M. [1 ,2 ]
Foley, Joe P. [2 ]
Striegel, Andre M. [3 ]
机构
[1] GlaxoSmithKline, Analyt Sci & Dev, 1250 S Collegeville Rd, Collegeville, PA 19426 USA
[2] Drexel Univ, Dept Chem, 3141 Chestnut St, Philadelphia, PA 19104 USA
[3] NIST, Chem Sci Div, 100 Bur Dr,MS 8392, Gaithersburg, MD 20899 USA
关键词
Size-exclusion chromatography; SEC; Polymer; Sodium polystyrene sulfonate; Polyelectrolyte; NaPSS; SYNTHETIC-POLYMERS; CHALLENGES; DYNAMICS; WATER; MODEL;
D O I
10.1016/j.chroma.2017.12.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The size-exclusion separation of a water-soluble polyelectrolyte polymer, sodium polystyrene sulfonate (NaPSS), was demonstrated on common reversed-phase (C-18, C-4, phenyl, and cyano) and hydrophilic interaction chromatography (HILIC) columns. The effect of common solvents - acetonitrile (ACN), tetrahydrofuran (THF), and methanol (MeOH), used as mobile phase modifiers - on the elution of NaPSS and the effect of column temperature (within a relatively narrow range corresponding to typical chromatographic conditions, i.e., 10 degrees C-60 degrees C) on the partition coefficient, K-SEC, were also investigated. Non-size-exclusion chromatography (non-SEC) effects can be minimized by the addition of an electrolyte and an organic modifier to the mobile phase, and by increasing the column temperature (e.g., to 50 degrees C or 60 degrees C). Strong solvents such as THF and ACN are more successful in the reduction of such effects than is the weaker solvent MeOH. The best performance is seen on medium polarity and polar stationary phases, such as cyanopropyl- and diol-modified silica (HILIC), where the elution of the NaPSS polyelectrolyte is by a near-ideal SEC mechanism. Hydrophobic stationary phases, such as C-18, C-4, and phenyl, require a higher concentration of a strong solvent modifier (THF) in the mobile phase to reduce non-SEC interactions of the solute with the stationary phase. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 174
页数:14
相关论文
共 50 条
  • [1] Size exclusion chromatography of synthetic polymers and biopolymers on common reversed phase and hydrophilic interaction chromatography columns
    Caltabiano, Anna M.
    Foley, Joe P.
    Barth, Howard G.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1437 : 74 - 87
  • [2] Organic solvent modifier and temperature effects in non-aqueous size-exclusion chromatography on reversed-phase columns
    Caltabiano, Anna M.
    Foley, Joe P.
    Striegel, Andre M.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1531 : 83 - 103
  • [3] PEPTIDE-MAPPING USING COMBINATIONS OF SIZE-EXCLUSION CHROMATOGRAPHY, REVERSED-PHASE CHROMATOGRAPHY AND CAPILLARY ELECTROPHORESIS
    STROMQVIST, M
    JOURNAL OF CHROMATOGRAPHY A, 1994, 667 (1-2) : 304 - 310
  • [4] Comparison of the adsorption mechanisms of pyridine in hydrophilic interaction chromatography and in reversed-phase aqueous liquid chromatography
    Gritti, Fabrice
    Pereira, Alberto dos Santos
    Sandra, Pat
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (48) : 8496 - 8504
  • [5] SIZE-EXCLUSION CHROMATOGRAPHY OF POLYELECTROLYTES - COMPARISON WITH THEORY
    DUBIN, PL
    LARTER, RM
    WU, CJ
    KAPLAN, JI
    JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (18): : 7243 - 7250
  • [6] SIZE-EXCLUSION CHROMATOGRAPHY OF CATIONIC AND ANIONIC POLYELECTROLYTES IN AQUEOUS-MEDIA
    KUHN, A
    FORSTER, S
    LOSCH, R
    ROMMELFANGER, M
    ROSENAUER, C
    SCHMIDT, M
    MAKROMOLEKULARE CHEMIE-RAPID COMMUNICATIONS, 1993, 14 (07): : 433 - 438
  • [7] Is hydrophilic interaction chromatography with silica columns a viable alternative to reversed-phase liquid chromatography for the analysis of ionisable compounds?
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1171 (1-2) : 46 - 55
  • [8] Imidazoline type stationary phase for hydrophilic interaction chromatography and reversed-phase liquid chromatography
    Li, Yuanyuan
    Feng, Yaoyao
    Chen, Tong
    Zhang, Haixia
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (35) : 5987 - 5994
  • [9] SEPARATION OF PROTEINS BY MICROCOLUMN LIQUID-CHROMATOGRAPHY BASED ON THE REVERSED-PHASE AND SIZE-EXCLUSION PRINCIPLES
    FLURER, CL
    BORRA, C
    ANDREOLINI, F
    NOVOTNY, M
    JOURNAL OF CHROMATOGRAPHY, 1988, 448 (01): : 73 - 86
  • [10] High-molecular weight impurity screening by size-exclusion chromatography on a reversed-phase column
    Lin, Ziqing
    Ye, Yun K.
    Ling, Melissa
    Shackman, Jonathan G.
    Ileka, Kevin M.
    Raglione, Thomas, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 196