Rapid method for evaluating reversed-phase high-performance liquid chromatography column stability

被引:28
|
作者
Fonseca, DA
Gutiérrez, HR
Collins, KE
Collins, CH
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[2] Univ Estadual Campinas, Inst Fis, BR-13084971 Campinas, SP, Brazil
关键词
stationary phases; LC; stability studies;
D O I
10.1016/j.chroma.2003.12.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure is presented for the rapid evaluation of HPLC stationary phase stability at pH 8.4 or 10.1 using a temperature of 60degreesC. Mobile phase (MeOH-0.1 mol 1(-1) aqueous NaHCO3, 50:50, v/v) is continuously passed through the column with periodic injections of a test solution until the several chromatographic parameters of the resulting chromatograms are degraded. The tests were applied to several commercial and laboratory-made stationary phases. After degradation two of these phases, one commercial and one laboratory-made, were examined by elemental analysis and scanning electron microscopy to elucidate the degradation process. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [21] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF METALLOPORPHYRINS
    BOREHAM, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 73 - GEOC
  • [22] INTRODUCTION TO REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    COLIN, H
    GUIOCHON, G
    JOURNAL OF CHROMATOGRAPHY, 1977, 141 (03): : 289 - 312
  • [23] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DOXYCYCLINE
    DELEENHEER, AP
    NELIS, HJCF
    JOURNAL OF CHROMATOGRAPHY, 1977, 140 (03): : 293 - 299
  • [24] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DACTINOMYCIN
    SCHNEEBAUM, S
    BIES, JM
    BRIELE, HA
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 427 (01): : 166 - 171
  • [25] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HISTONES
    CERTA, U
    VONEHRENSTEIN, G
    ANALYTICAL BIOCHEMISTRY, 1981, 118 (01) : 147 - 154
  • [26] Reversed-phase high-performance liquid chromatography in grain applications
    Lookhart, GL
    Bean, SR
    Bietz, JA
    CEREAL FOODS WORLD, 2003, 48 (01) : 9 - 16
  • [27] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES
    NAKAZAWA, H
    NAGASE, M
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1986, 106 (05): : 398 - 405
  • [28] Microcolumn reversed-phase high-performance liquid chromatography of phenols
    Rudakov, OB
    Selemenev, VF
    Spitchenko, ON
    Konovalov, VV
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY, 2002, 76 (05): : 828 - 832
  • [29] RAPID SEPARATION OF PLATELET NUCLEOTIDES BY REVERSED-PHASE, ISOCRATIC, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A RADIALLY COMPRESSED COLUMN
    RAO, GHR
    PELLER, JD
    WHITE, JG
    JOURNAL OF CHROMATOGRAPHY, 1981, 226 (02): : 466 - 470
  • [30] Estimation of the phase ratio in reversed-phase high-performance liquid chromatography