Rapid method for evaluating reversed-phase high-performance liquid chromatography column stability

被引:28
|
作者
Fonseca, DA
Gutiérrez, HR
Collins, KE
Collins, CH
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[2] Univ Estadual Campinas, Inst Fis, BR-13084971 Campinas, SP, Brazil
关键词
stationary phases; LC; stability studies;
D O I
10.1016/j.chroma.2003.12.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure is presented for the rapid evaluation of HPLC stationary phase stability at pH 8.4 or 10.1 using a temperature of 60degreesC. Mobile phase (MeOH-0.1 mol 1(-1) aqueous NaHCO3, 50:50, v/v) is continuously passed through the column with periodic injections of a test solution until the several chromatographic parameters of the resulting chromatograms are degraded. The tests were applied to several commercial and laboratory-made stationary phases. After degradation two of these phases, one commercial and one laboratory-made, were examined by elemental analysis and scanning electron microscopy to elucidate the degradation process. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] A RAPID ANALYTICAL METHOD FOR BENOMYL BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ZWEIG, G
    GAO, RY
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 29 - PEST
  • [2] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD DEVELOPMENT BASED ON COLUMN SELECTIVITY
    DESTEFANO, JJ
    LEWIS, JA
    SNYDER, LR
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1992, 10 (02): : 130 - &
  • [3] Column Characterization and Selection Systems in Reversed-Phase High-Performance Liquid Chromatography
    Zuvela, Petar
    Skoczylas, Magdalena
    Liu, J. Jay
    Baczek, Tomasz
    Kaliszan, Roman
    Wong, Ming Wah
    Buszewski, Boguslaw
    Heberger, Karoly
    CHEMICAL REVIEWS, 2019, 119 (06) : 3674 - 3729
  • [4] Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography
    Claessens, HA
    vanStraten, MA
    Kirkland, JJ
    JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) : 259 - 270
  • [5] A rapid analytical method of major milk proteins by reversed-phase high-performance liquid chromatography
    Ma, Lu
    Yang, Yongxin
    Chen, Jingting
    Wang, Jiaqi
    Bu, Dengpan
    ANIMAL SCIENCE JOURNAL, 2017, 88 (10) : 1623 - 1628
  • [6] Rapid separation of soybean globulins by reversed-phase high-performance liquid chromatography
    Garcia, MC
    Torre, M
    Laborda, F
    Marina, ML
    JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (01) : 75 - 83
  • [7] RAPID ANALYSIS FOR CODEINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PAPADOYANNIS, IN
    CADDY, B
    ANALYTICAL LETTERS, 1986, 19 (9-10) : 1065 - 1081
  • [8] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HEARN, MTW
    METHODS IN ENZYMOLOGY, 1984, 104 : 190 - 212
  • [9] COMPARISON OF REVERSED-PHASE COLUMN MATERIALS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS
    VANDERZEE, R
    HOEKZEMA, T
    WELLINGWESTER, S
    WELLING, GW
    JOURNAL OF CHROMATOGRAPHY, 1986, 368 (02): : 283 - 289
  • [10] ON-COLUMN ENDCAPPING AND DERIVATIZATION IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    VERZELE, M
    DECONINCK, M
    DEWAELE, C
    GEERAERT, E
    CHROMATOGRAPHIA, 1984, 19 : 443 - 447