High intensity focused ultrasound combined with ultrasound-guided suction curettage treatment for cesarean scar pregnancy: a comparison of different HIFU sonication strategies

被引:5
|
作者
Yin, Yan [1 ]
Pan, Feibao [2 ]
He, Min [3 ,4 ]
Zhang, Cai [3 ,4 ]
Liu, Yang [1 ]
机构
[1] Peoples Hosp Deyang City, Dept Obstet & Gynaecol, 173 Taishan North Rd, Deyang 618000, Sichuan, Peoples R China
[2] Suining Cent Hosp, Dept Cerebrovasc Dis, Suining, Peoples R China
[3] Chongqing Med Univ, Coll Biomed Engn, State Key Lab Ultrasound Med & Engn, Chongqing, Peoples R China
[4] Chongqing Med Univ, Chongqing Key Lab Biomed Engn, Chongqing, Peoples R China
关键词
High-intensity focused ultrasound; cesarean scar pregnancy; efficacy; safety; sonication strategy; UTERINE FIBROIDS; MANAGEMENT; ABLATION; SAFETY;
D O I
10.1080/02656736.2022.2044078
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To explore a new high-intensity focused ultrasound (HIFU) sonication strategy for cesarean scar pregnancy (CSP) and to compare the clinical effectiveness and safety of this new HIFU sonication strategy with the conventional HIFU sonication strategy followed by ultrasound-guided dilation and curettage (USg-D&C) for CSP. Materials and methods 91 patients with CSP treated by HIFU and USg-D&C in People's Hospital of Deyang City between January 2017 and December 2019 were retrospectively reviewed in this study. Based on the HIFU sonication strategy, patients were divided to two groups: 44 patients were exposed to 'C-shape' sonication layer by layer around the implantation location of the pregnancy sac (control group), while the other 47 patients were exposed to 'I-shape' sonication layer by layer only on the deep part which close to the bladder of the implantation location of the pregnancy sac (experimental group). The differences in clinical efficacy between the two groups were analyzed. Baseline characteristics, technical parameters of HIFU treatment and USg-D&C data were recorded. Adverse events were also recorded. Results No statistically significant difference was observed between the two groups in baseline characteristics including age, body mass index (BMI), menopause time, largest diameter of gestational sac, pretreatment serum beta-hCG, thickness of gestational sac, embedding myometrium, previous cesarean sections and interval from last cesarean section (CS). The average treatment intensity in the experimental group was significantly lower than that in the control group (p < .05). The median sonication time, total energy used for HIFU ablation, and energy efficiency factor (EEF) in the experimental group were significantly lower than the control group (p < .05). No statistically significant difference was observed between the two groups in treatment power and treatment time (p > .05). Sciatic/buttock pain and postoperative lower abdominal pain in the control group were significantly stronger than that in the experimental group (p < .05). There were no statistically significant differences in post-HIFU vaginal bleeding and discharging, urinary tract irritation, the operation time of USg-D&C, the amount of vaginal bleeding during USg-D&C, and the time for serum beta-hCG back to a normal level between the two groups (p > .05). Conclusions The 'I-shape' strategy of HIFU treatment for CSP was effective and safe, with shorter sonication time, less energy input and lower incidence of sonication-related pain occurred in postoperative lower abdominal and sciatic nerve/buttock.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 50 条
  • [21] Is ultrasound-guided suction curettage a reliable option for treatment of cesarean scar pregnancy? A cross-sectional retrospective study
    Ozcan, Huseyin Caglayan
    Ugur, Mete Gurol
    Balat, Ozcan
    Sucu, Seyhun
    Mustafa, Aynur
    Tepe, Neslihan Bayramoglu
    Ugur, Berna Kaya
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2018, 31 (22): : 2953 - 2958
  • [22] Ultrasound-guided High Intensity Focused Ultrasound (HIFU) ablation of placental vasculature
    Shaw, C. J.
    Civale, J.
    Giussani, D. A.
    Rivens, I
    ter Haar, G.
    Lees, C. C.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2015, 122 : 54 - 54
  • [23] Clinical Assessment of Ultrasound-Guided Local Lauromacrogol Injection Combined With Curettage and Hysteroscopy for Cesarean Scar Pregnancy
    Wu, Qing
    Liu, Xia
    Zhu, Lin
    Zhu, Yichen
    Mei, Tingting
    Cao, Shanshan
    Shen, Yan
    Ding, Jun
    Lin, Tan
    FRONTIERS IN PHARMACOLOGY, 2020, 11
  • [24] Doppler Ultrasound Evaluation of the Efficacy of High Intensity Focused Ultrasound in Treatment of Cesarean Section Scar Pregnancy
    Huo, Xiaokai
    Xie, Yaozeng
    Yang, Lei
    Deng, Kun
    Liu, Yingying
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (03): : 240 - 244
  • [25] Ultrasound-guided dilatation and curettage in life-threatening cesarean scar ectopic pregnancy
    Bianchi, P.
    Cozza, G.
    Salvatori, M. M.
    Giovanale, V.
    Vitali, M.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2014, 179 : 252 - 252
  • [26] Comparison of two different suction curettage methods in cesarean scar pregnancy treatment
    Elmas, Burak
    Ozturk, Neslihan
    Kizil, Emine
    Koc, Bergen Laleli
    Zorlu, Ugurcan
    Ersak, Duygu Tugrul
    Aktas, Turkan Dikici
    Erten, Asuman
    Erkaya, Salim
    BMC PREGNANCY AND CHILDBIRTH, 2024, 24 (01)
  • [27] Cesarean scar pregnancy: noninvasive and effective treatment with high-intensity focused ultrasound
    Xiao, Juhua
    Zhang, Shouhua
    Wang, Fang
    Wang, Yuqin
    Shi, Zhen
    Zhou, Xin
    Zhou, Jinshui
    Huang, Jinshi
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 211 (04) : 356.e1 - 356.e7
  • [28] Experimental Evaluation of an Ultrasound-Guided High-Intensity-Focused Ultrasound Probe for Sonication of Artery
    Huang, Qianwen
    Zhou, Yun
    Pan, Lei
    Chen, Yini
    Wang, Nianou
    Li, Ke
    Bai, Jingfeng
    Ji, Xiang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (12) : 2357 - 2373
  • [29] CT and ultrasound guided stereotactic high intensity focused ultrasound (HIFU)
    Wood, Bradford J.
    Yanof, J.
    Frenkel, V.
    Viswanathan, A.
    Dromi, S.
    Oh, K.
    Kruecker, J.
    Bauer, C.
    Seip, R.
    Kam, A.
    Li, K. C. P.
    THERAPEUTIC ULTRASOUND, 2006, 829 : 122 - +
  • [30] Clinical efficacy and safety of high-intensity focused ultrasound (HIFU) ablation in treatment of cesarean scar pregnancy (CSP) I and II
    Liu, Yanglu
    Yin, Qiaozhi
    Xu, Fan
    Luo, Shuang
    BMC PREGNANCY AND CHILDBIRTH, 2022, 22 (01)