Accidental embryo irradiation during barium enema examinations - An estimation of absorbed dose

被引:18
|
作者
Damilakis, J
Perisinakis, K
Grammatikakis, J
Panayiotakis, G
Gourtsoyiannis, N
机构
[1] UNIV HOSP IRAKLION,DEPT MED PHYS,IRAKLION,CRETE,GREECE
[2] UNIV HOSP IRAKLION,DEPT RADIOL,IRAKLION,CRETE,GREECE
[3] UNIV PATRAS,DEPT MED PHYS,PATRAI,GREECE
关键词
fetus; pregnancy; dosimetry; radiation;
D O I
10.1097/00004424-199604000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES To investigate the possibility of an embryo to receive a dose of more than 10 cGy, the threshold of malformations induction in embryos reported by the International Commission on Radiological Protection, during barium enema examinations. METHODS. Thermoluminescent dosimeters were placed in a phantom to calculate the depth-to-skin conversion coefficient needed for dose estimation at the average embryo depth in patients, Barium enema examinations were performed in 20 women of childbearing age with diagnostic problems demanding longer fluoroscopy times, Doses at 6 cm, the average embryo depth, were determined by measurements at the patients' skin followed by dose calculation at the site of interest. RESULTS. The range of doses estimated at embryo depth for patients was 1.9 to 8.1 cGy, The dose always exceeded 5 cGy when fluoroscopy time was longer than 7 minutes. CONCLUSION. The dose at the embryo depth never exceeded 10 cGy, This study indicates that fluoroscopy time should not exceed 7 minutes in childbearing-age female patients undergoing barium enema examinations.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 45 条
  • [21] Proton and photon absorbed-dose conversion coefficients for embryo and foetus from top-down irradiation geometry
    Chen, Jing
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 85 - 88
  • [22] 18F-Fludeoxyglucose Absorbed Dose Estimation in Fetus during Early Pregnancy
    Ahmadi, Nemat
    Karimian, Alireza
    Nasrabadi, Mehdi Nasri
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (02): : 171 - 175
  • [23] Estimation of Dose Distribution in Lung during Total Body Irradiation
    Maciejczyk, A.
    Janiszewska, M.
    Raczkowski, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S638 - S638
  • [24] Estimation of Pediatric Radiation Dose and Organ Dose During Multi-Detector Computed Tomography Examinations
    Alameen, Suhaib
    Bashir, Alaa E.H.
    Khogali, Wadah
    Abuzaid, Mohamed M.
    SSRN, 2023,
  • [25] Breast radiation dose equivalent and cancer risk estimation during PET/ CT examinations
    Jambi, Layal
    Alkhorayef, Mohammed
    Almuwanis, Mohammed
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [26] Estimation of dose and light distributions in water during irradiation of muon beams
    Hirano, Yoshiyuki
    Ninomiya, Kazuhiko
    Yamamoto, Seiichi
    PHYSICA SCRIPTA, 2019, 94 (12)
  • [27] RADIATION-DOSE IN INVESTIGATIONS OF THE LARGE-BOWEL - COMPARISON OF RADIATION-DOSES IN EXAMINATIONS OF THE COLON WITH DOUBLE-CONTRAST BARIUM ENEMA WITH THE WELIN MODIFICATION AND COLONOSCOPY
    GEERDSEN, J
    PEDERSEN, VM
    KJAERGARD, H
    NORDKILD, P
    ANDERSEN, J
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (05) : 556 - 558
  • [28] CALCULATION OF NON-EQUILIBRIUM DISTRIBUTIONS OF ABSORBED DOSE AND SPACE-CHARGE DURING GAMMA-IRRADIATION
    ADADUROV, AF
    LAZURIK, VT
    SOVIET ATOMIC ENERGY, 1982, 52 (03): : 205 - 207
  • [29] ESTIMATION OF ORGAN DOSE DURING RADIOLOGICAL AND COMPUTER TOMOGRAPHIC EXAMINATIONS WITH CALCULATIONS OF THE SOMATICALLY SIGNIFICANT DOSES
    EWEN, K
    STEINER, H
    JUNGBLUT, R
    GUNTHER, D
    SCHOPPE, WD
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1980, 133 (04): : 425 - 429
  • [30] ESTIMATION OF EFFECTIVE DOSE TO THE PATIENT DURING MEDICAL X-RAY EXAMINATIONS FROM MEASUREMENTS OF THE DOSE AREA PRODUCT
    LEHERON, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (11): : 2117 - 2126