Comparison of streamlined liner of the pharynx airway (SLIPA™) and laryngeal mask airway: a systematic review and meta-analysis

被引:9
|
作者
Choi, G. J. [1 ]
Kang, H. [1 ]
Baek, C. W. [1 ]
Jung, Y. H. [1 ]
Woo, Y. C. [1 ]
Kim, S. H. [2 ]
Kim, J. G. [2 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Anaesthesiol & Pain Med, Seoul 156756, South Korea
[2] Chung Ang Univ, Coll Med, Dept Internal Med, Seoul 156756, South Korea
基金
新加坡国家研究基金会;
关键词
PROSEAL(TM); PRESSURE;
D O I
10.1111/anae.13035
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). The relative risk (95% CI) of bloodstaining of the device (nine studies, 859 patients) was 2.09 (1.46-3.00) for the streamlined liner of the pharynx airway compared with the laryngeal mask airway. Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.
引用
收藏
页码:613 / 622
页数:10
相关论文
共 50 条
  • [21] A systematic review and meta-analysis of the i-gel® vs laryngeal mask airway in children
    Choi, G. J.
    Kang, H.
    Baek, C. W.
    Jung, Y. H.
    Woo, Y. C.
    Cha, Y. J.
    ANAESTHESIA, 2014, 69 (11) : 1258 - 1265
  • [22] A systematic review and meta-analysis of the i-gel® vs laryngeal mask airway in adults
    de Montblanc, J.
    Ruscio, L.
    Mazoit, J. X.
    Benhamou, D.
    ANAESTHESIA, 2014, 69 (10) : 1151 - 1162
  • [23] Effect of Laryngeal Mask Airway Insertion on Intraocular Pressure Response: Systematic Review and Meta-Analysis
    Obsa, Mohammed Suleiman
    Kanche, Zewde Zema
    Fite, Robera Olana
    Tura, Tilahun Saol
    Adema, Bulcha Guye
    Kinfe, Aseb Arba
    Kercho, Melkamu Worku
    Chanko, Kebreab Paulos
    Shanka, Getahun Molla
    Lencha, Atkuregn Alemayehu
    Azeze, Gedion Asnake
    Hanfore, Lolemo Kelbiso
    Adulo, Nefsu Awoke
    Dessu, Blen Kassahun
    Wolde, Getahun Dendir
    Workie, Shimelash Bitew
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2020, 2020
  • [24] A randomized comparison of pediatric-sized Streamlined Liner of Pharyngeal Airway and Laryngeal Mask Airway-Unique in paralyzed children
    Zhu, Wenxiu
    Wei, Xinchuan
    PEDIATRIC ANESTHESIA, 2016, 26 (05) : 557 - 563
  • [25] Severe hoarseness associated with the streamlined liner of the pharyngeal airway (SLIPA™)
    Ma, X. -X.
    Fang, X. -M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2015, 59 (04) : 531 - 535
  • [26] Comparison of the I-Gel and the Laryngeal Mask Airway Proseal during General Anesthesia: A Systematic Review and Meta-Analysis
    Park, Sun Kyung
    Choi, Geun Joo
    Choi, Yun Suk
    Ahn, Eun Jin
    Kang, Hyun
    PLOS ONE, 2015, 10 (03):
  • [27] Comparison of Laryngoscope-Guided Insertion and Standard Blind Insertion of the Laryngeal Mask Airway: A Systematic Review and Meta-Analysis
    Zheng, Zhihao
    Li, Haibo
    Dai, Congcong
    Bi, Liwei
    Sun, Wei
    Yu, Miao
    Hu, Zhanfei
    Liang, Xiaodong
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2025, 2025 (01)
  • [28] Comparison Between the Cobra Perilaryngeal Airway and Laryngeal Mask Airways Under General Anesthesia: A Systematic Review and Meta-analysis
    Xu, Rui
    Zhu, Yun
    Fan, Qing
    Shen, Xia
    Li, Wen Xian
    ANESTHESIA AND ANALGESIA, 2017, 125 (03): : 958 - 966
  • [29] Brief review: The Cobra Perilaryngeal Airway (CobraPLA®) and the Streamlined Liner of Pharyngeal Airway (SLIPA™) supraglottic airwaysArticle de synthèse court : Les dispositifs supraglottiques Cobra Perilaryngeal Airway (CobraPLA®) et Streamlined Liner of Pharyngeal Airway (SLIPA™)
    Hedieh Hooshangi
    David T. Wong
    Canadian Journal of Anesthesia, 2008, 55 (3): : 177 - 185
  • [30] Effectiveness of the Streamlined Liner of the Pharynx Airway (SLIPA™) in allowing positive pressure ventilation during gynaecological laparoscopic surgery
    Hong, S. J.
    Ko, K. M.
    Park, J. H.
    Kim, I. S.
    Hwang, S. M.
    Shin, K. M.
    Yoon, Y. J.
    Kang, S. S.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (04) : 618 - 622