The quantitative analysis of sugar maple tree rings by laser ablation in conjunction with ICP-MS

被引:28
|
作者
Watmough, SA [1 ]
Hutchinson, TC [1 ]
Evans, RD [1 ]
机构
[1] Trent Univ, ERS Program, Peterborough, ON K9J 7B8, Canada
关键词
D O I
10.2134/jeq1998.00472425002700050014x
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study reports on the quantitative analysis of sugar maple (Acer saccharum Marsh.) tree rings by laser-ablation ICP-MS (LAS). Differences in ablation were corrected using C-13 as an internal standard. Spatial variation in element distribution within individual tree rings was low, allowing individual tree rings to be used as calibration standards. The relative standard deviation (RSD) for element concentrations within tree rings were 15% for Mg, 15% for Ca, 9% for K, and 16% for Pb. This variation is likely doe to element distribution and not the ablation process; the RSD for C-13 was <4%. Tree cores were taken from three sugar maple trees adjacent to a major highway, 24 km east of Toronto. Concentrations of Ca, Mg, and K generally declined from pith to cambium, a Feature commonly observed in tree boles. Peaks in Pb concentration, between 3 and 5 mg Pb kg(-1),were found in tree rings formed between 1940 and 1970, although there was considerable year-to-year variation within each tree, and the timing and magnitude of the Pb peaks differed between trees. Lead concentrations decreased in wood formed after 1970 so that by the 1980s, Pb concentrations were around 1 mg kg(-1), reflecting changes in Pb deposition into the woodland.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [21] Application of laser ablation ICP-MS to the analysis of forensic glass samples
    Neufeld, LM
    SPECTROSCOPY, 2005, 20 (07) : 31 - 36
  • [22] Major element analysis of natural silicates by laser ablation ICP-MS
    Humayun, Munir
    Davis, Fred A.
    Hirschmann, Marc M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (07) : 998 - 1005
  • [23] Evaluation of infrared femtosecond laser ablation for the analysis of geomaterials by ICP-MS
    Freydier, R.
    Candaudap, F.
    Poitrasson, F.
    Arbouet, A.
    Chatel, B.
    Dupre, B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) : 702 - 710
  • [24] APPLICATION OF LASER-ABLATION ICP-MS TO ELEMENTAL ANALYSIS OF GLASSES
    IMBERT, JL
    TELOUK, P
    MIKROCHIMICA ACTA, 1993, 110 (4-6) : 151 - 160
  • [25] ICP-MS laser ablation oak wood metals wood standard semi-quantitative analysis
    Alteyrac, J
    Augagneur, S
    Medina, B
    Vivas, N
    Glories, Y
    ANALUSIS, 1995, 23 (10) : 523 - 526
  • [26] A CRITICAL-LOOK AT QUANTITATIVE LASER-ABLATION ICP-MS ANALYSIS OF NATURAL AND SYNTHETIC GLASSES
    STIX, J
    GAUTHIER, G
    LUDDEN, JN
    CANADIAN MINERALOGIST, 1995, 33 : 435 - 444
  • [27] Quantitative analysis of total and insoluble elements and inclusion composition in metal by laser ablation ICP-MS method
    Karasev, AV
    Inoue, R
    Suito, H
    ISIJ INTERNATIONAL, 2001, 41 (07) : 757 - 765
  • [28] LASER ABLATION ICP-MS: APPLICATION IN BIOMEDICAL RESEARCH
    Sussulini, Alessandra
    Becker, J. Susanne
    Becker, J. Sabine
    MASS SPECTROMETRY REVIEWS, 2017, 36 (01) : 47 - 57
  • [29] Laser ablation ICP-MS developments and trends for 2003
    Sylvester, PJ
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2005, 29 (01) : 41 - 52
  • [30] Identification of pharmaceutical glasses by laser ablation ICP-MS
    Schmidt, T
    Surmann, JP
    Stephanowitz, H
    Hoffmann, E
    PHARMAZIE, 2001, 56 (11): : 852 - 856