Assessment of Choroidal Neovascularization Perfusion: A Pilot Study With Laser Speckle Flowgraphy

被引:13
|
作者
Calzetti, Giacomo [1 ]
Mora, Paolo [1 ]
Favilla, Stefania
Ottonelli, Giorgia [1 ]
Devincenzi, Giulia [1 ]
Carta, Arturo [1 ]
Tedesco, Salvatore [1 ]
Mursch-Edlmayr, Anna [2 ]
Garhoefer, Gerhard [3 ]
Gandolfi, Stefano [1 ]
Schmetterer, Leopold [3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] Univ Hosp Parma, Ophthalmol Unit, Parma, Italy
[2] Kepler Univ Clin, Johannes Kepler Univ, Dept Ophthalmol, Linz, Austria
[3] Med Univ Vienna, Dept Clin Pharmacol, Vienna, Austria
[4] Singapore Eye Res Inst, 11 Third Hosp Ave, Singapore 168751, Singapore
[5] Nanyang Technol Univ, Singapore, Singapore
[6] Duke NUS Med Sch, Ophthalmol & Visual Sci Acad Clin Program, Singapore, Singapore
[7] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[8] Inst Ophthalmol, Basel, Switzerland
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2020年 / 9卷 / 05期
关键词
laser speckle flowgraphy; imaging; choroid; age-related macular degeneration; anti-VEGF; COHERENCE TOMOGRAPHY ANGIOGRAPHY; INDOCYANINE GREEN ANGIOGRAPHY; OCULAR BLOOD-FLOW; MACULAR DEGENERATION; INTRAVITREAL BEVACIZUMAB; QUANTITATIVE-ANALYSIS; RANIBIZUMAB; CIRCULATION; INJECTION; VASCULOPATHY;
D O I
10.1167/tvst.9.5.9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to quantify perfusion in the area of choroidal neovascularization (CNV) using laser speckle flowgraphy (LSFG) before and after intravitreal anti-vascular endothelial growth factor (VEGF) injection. Methods: Retrospective case series. Fifteen eyes of 15 patients with treatment-naive CNV due to age-related macular degeneration (AMD) and with available LSFG images were included. The main outcome was the mean blur rate (MBR) quantified as a measure of perfusion within the CNV area observed on indocyanine green angiography. Twelve patients had available longitudinal data until one month after the injection, used to evaluate changes in perfusion, central macular thickness (CMT), visual acuity, and ocular perfusion pressure. Reproducibility of LSFG measurements was investigated at each time point from two images taken within five minutes. Results: Intraclass correlation coefficients for LSFG measurements were higher than 0.8 indicating excellent reproducibility. There was a significant decrease in perfusion after one week (-26.4 +/- 14.4%; P= 0.027), whereas, after one month, perfusion was no longer significantly different from baseline (P = 0.121). CMT showed a progressive decrease over the follow-up period. Changes in perfusion were strongly correlated with changes in CMT after one week, but not thereafter. Conclusions: This pilot study suggests a method to select a region in the CNV area to quantify perfusion using LSFG. MBR could represent a parameter possibly related to regrowth of the CNV after anti-VEGF treatment. Large-scale studies are needed to assess the usefulness of LSFG in defining re-treatment criteria for neovascular AMD. Translational Relevance: LSFG technology to quantify perfusion could provide useful biomarkers for therapeutic management of CNV.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A Superpixel-Histogram Method to Analyze Retinal, Optic Nerve, and Choroidal Blood Flow Using Laser Speckle Flowgraphy
    Wang, Jui-Kai
    Tamplin, Michelle R.
    Garvin, Mona K.
    Grumbach, Isabella M.
    Kardon, Randy H.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [32] Usefulness of Laser Speckle Flowgraphy for the Assessment of Ocular Blood Flow in Extracranial-Intracranial Bypass
    Omodaka, Shunsuke
    Endo, Hidenori
    Doi, Hiroshi
    Shimizu, Hiroaki
    Fujimura, Miki
    Aizawa, Naoko
    Nakazawa, Toru
    Tominaga, Teiji
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (10): : E445 - E448
  • [33] Association Between Cardio-Ankle Vascular Index and Choroidal Circulation Assessed by Laser Speckle Flowgraphy in Diabetic Retinopathy
    Hashimoto, Ryuya
    Tanaka, Kazufumi
    Fujioka, Naoki
    Yata, Keisuke
    Yamazaki, Ryo
    Okamoto, Kenji
    Maeno, Takatoshi
    Yagi, Fumihiko
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [34] Assessment of chorioretinal blood flow and vessel diameter by laser speckle flowgraphy in three animal models
    Wei, X.
    Barathi, A.
    Sai, B. B.
    Balne, P. K.
    Khandelwal, N.
    Agrawal, R.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [35] Choroidal blood flow velocity and resistance in inferior posterior staphyloma using a novel superpixel technique in laser speckle flowgraphy
    Saito, Michiyuki
    Mitamura, Mizuho
    Yokoi, Koichi
    Hirooka, Kiriko
    Dong, Zhenyu
    Ando, Ryo
    Kase, Satoru
    Ishida, Susumu
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [36] Laser Speckle Contrast Imaging for Intraoperative Quantitative Assessment of Intestinal Blood Perfusion During Colorectal Surgery: A Prospective Pilot Study
    Kojima, Shigehiro
    Sakamoto, Tsuguo
    Nagai, Yuko
    Matsui, Yutaka
    Nambu, Kyojiro
    Masamune, Ken
    SURGICAL INNOVATION, 2019, 26 (03) : 293 - 301
  • [37] Laser speckle flowgraphy has comparable accuracy to indocyanine green fluorescence angiography in assessing bowel blood perfusion
    Kaneko, Tomoaki
    Funahashi, Kimihiko
    Ito, Yuko
    Ushigome, Mitsunori
    Kagami, Satoru
    Yoshida, Kimihiko
    Suzuki, Takayuki
    Miura, Yasuyuki
    Kurihara, Akiharu
    LANGENBECKS ARCHIVES OF SURGERY, 2024, 409 (01)
  • [38] Use of the laser speckle flowgraphy in posterior fundus circulation research
    Akiko Kogure
    Kaori Yamamoto
    Sadao Hori
    中华医学杂志(英文版), 2011, (24) : 4339 - 4344
  • [39] VISUALIZATION OF RETINAL BLOOD-FLOW BY LASER SPECKLE FLOWGRAPHY
    FUJII, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (03) : 302 - 304
  • [40] New laser speckle flowgraphy system using CCD camera
    Konishi, N
    Tokimoto, Y
    Kohra, K
    Fujii, H
    OPTICAL REVIEW, 2002, 9 (04) : 163 - 169