CFRP Rod Panel Retrofit of Impact Damaged RC Bridge Girders

被引:0
|
作者
Peiris, A. [1 ]
Harik, I. [1 ]
机构
[1] Univ Kentucky, Lexington, KY 40506 USA
关键词
CFRP; Rod panel; Impact damage; Residual capacity; Bridge retrofit;
D O I
10.1007/978-981-13-7603-0_49
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Impact of over-height trucks can cause considerable damage to concrete bridge girders. CFRP rod panels (CRPs) have emerged as an effective method of externally strengthening concrete structures. Both exterior beams of a reinforced concrete bridge over southbound Interstate 71 (I-71) in Kentucky were damaged due to an over-height truck impact. Two of fiveNo. 36 rebar (Diameter = 35.8mm, Area= 1006 mm(2)) in the bottom mat of each exterior beam was severely bent due to the impact. In addition, shear reinforcing bars in the vicinity of the impact were cut-off. CRPs were deployed to replace the load carrying capacity lost due to the damaged rebar. CRPs were chosen due to their modular construction capability, allowing the retrofit construction to be carried out using a smaller construction crew, and utilizing only a single lane closure on the interstate highway. CRP 195, with CFRP rods of 3.96-mm diameter, having a capacity of 870 kN per 300 mm width of panel, were selected for the flexural strengthening. Triaxial braided CFRP fabric (0 degrees, +/- 60 degrees) was selected for shear strengthening and served as containment of crushed concrete in the event of future over-height impacts. CRPs were found to be an excellent choice for the retrofit of impacted RC bridge girders, especially over multi-lane highways.
引用
收藏
页码:498 / 508
页数:11
相关论文
共 50 条
  • [21] Flexural Reliability of CFRP-Strengthened Bridge Girders
    Dardar, Safaa
    Eamon, Christopher D.
    Parra-Montesinos, Gustavo
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2024, 38 (01)
  • [22] CFRP shear strengthening system for steel bridge girders
    Kazem, Hamid
    Zhang, Ye
    Rizkalla, Sami
    Seracino, Rudolf
    Kobayashi, Akira
    ENGINEERING STRUCTURES, 2018, 175 : 415 - 424
  • [23] HEAT-STRAIGHTENING PROTOTYPE DAMAGED BRIDGE GIRDERS
    AVENT, RR
    FADOUS, GM
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1989, 115 (07): : 1631 - 1649
  • [24] Effectiveness of Fiber Anchors in CFRP Flexural Strengthening of RC Girders
    Rasheed, Hayder A.
    Zaki, Mohammed A.
    Raheem, Mustafa M.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2024, 28 (04)
  • [25] Experimental evaluation of seismic performance of corroded precast RC bridge columns and the retrofit measure using CFRP jackets
    Wang, Xu
    Wu, Suiwen
    Jia, Junfeng
    Li, Huaqiang
    Wei, Yanjian
    Zhang, Kaidi
    Bai, Yulei
    ENGINEERING STRUCTURES, 2021, 245
  • [26] Design Guidelines for Rapid Repair of Earthquake-Damaged Circular RC Bridge Columns Using CFRP
    Vosooghi, Ashkan
    Saiidi, M. Saiid
    JOURNAL OF BRIDGE ENGINEERING, 2013, 18 (09) : 827 - 836
  • [27] Numerical analysis of the mechanical behavior of the impact-damaged RC beams strengthened with CFRP
    Jin, Liu
    Lan, Yuchang
    Zhang, Renbo
    Du, Xiuli
    COMPOSITE STRUCTURES, 2021, 274
  • [28] Effective CFRP retrofit strategy for flexural deficient RC beams
    Banjara, Nawal Kishor
    Ramanjaneyulu, K.
    STRUCTURAL ENGINEERING AND MECHANICS, 2019, 69 (02) : 163 - 175
  • [29] CFRP Strip Cable Retrofit of RC Frame for Collapse Resistance
    Liu, T.
    Xiao, Y.
    Yang, J.
    Chen, B. S.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (01)
  • [30] Damaged RC beams repaired by bonding of CFRP laminates
    Benjeddou, Omrane
    Ben Ouezdou, Mongi
    Bedday, Aouicha
    CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (06) : 1301 - 1310