Scleral Buckling with a Non-Contact Wide-Angle Viewing System

被引:73
|
作者
Aras, Cengiz [1 ,2 ]
Ucar, Didar [2 ]
Koytak, Arif [1 ]
Yetik, Huseyin [2 ]
机构
[1] Bezmialem Vakif Univ, Fac Med, Dept Ophthalmol, TR-34093 Istanbul, Turkey
[2] Istanbul Univ, Dept Ophthalmol, Cerrahpasa Fac Med, Istanbul, Turkey
关键词
Scleral buckling; Retinal detachment; Wide-angle viewing system; RETINAL-DETACHMENT;
D O I
10.1159/000333101
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the outcome of scleral buckling surgery using a non-contact wide-angle viewing system for fundus visualization in patients with rhegmatogenous retinal detachment without proliferative vitreoretinopathy. Patients and Methods: Sixteen eyes of 16 patients underwent scleral buckling using a non-contact wide-angle viewing system combined with a 25-gauge illumination fibre inserted into the sclera at the pars plana. Results: The mean age of the patients was 53.6 +/- 13.7 years and the mean follow-up time was 13.4 +/- 2.8 months. Retinal reattachment was achieved in 13 of the 16 eyes (81%). Three eyes underwent vitrectomy with silicone oil injection because of development of proliferative vitreoretinopathy in 2 eyes and scleral perforation due to excessive indentation during cryoretinopexy in 1 eye. Two eyes developed limited subretinal haemorrhage during subretinal fluid drainage. Conclusion: Simultaneous use of a non-contact wide-angle viewing system combined with a 25-gauge light fibre illumination for fundus visualization brings the advantages of microsurgery and indirect ophthalmoscopy into scleral buckling surgery. Copyright (C) 2011 S. Karger AG, Basel
引用
收藏
页码:107 / 110
页数:4
相关论文
共 50 条
  • [41] NON-CONTACT, SHORT DISTANCE MEASURING SYSTEM FOR WIDE APPLICATIONS
    Yurish, Sergey Y.
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 643 - 647
  • [42] 25G compared with 20G vitrectomy under Resight non-contact wide-angle lenses for Terson syndrome
    Mao, Xinbang
    You, Zhipeng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (02) : 1193 - 1197
  • [43] Autoclavable wide-angle contact lens for vitreous surgery
    Shah, VA
    Chalam, KV
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (02) : 359 - 360
  • [44] Comparison of ultra wide-field fluorescein angiography using the Optos® P200Tx and Heidelberg Spectralis® the non-contact wide-angle lens
    Parlitsis, George
    Witmer, Matthew
    Patel, Sarju
    Kiss, Szilard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [45] Viewing Turnover through a Wide-Angle Lens: Conceptualizing Locality Turnover
    Windeler, Jaime
    Moore, Jo Ellen
    Riemenschneider, Cindy
    2015 48TH HAWAII INTERNATIONAL CONFERENCE ON SYSTEM SCIENCES (HICSS), 2015, : 4629 - 4639
  • [46] A NEW DEVICE FOR NONCONTACT WIDE-ANGLE VIEWING OF THE FUNDUS DURING VITRECTOMY
    BOVEY, EH
    GONVERS, M
    ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (12) : 1572 - 1573
  • [47] Vitreoretinal instruments: Vitrectomy cutters, endoillumination and wide-angle viewing systems
    de Oliveira P.R.C.
    Berger A.R.
    Chow D.R.
    International Journal of Retina and Vitreous, 2 (1)
  • [48] Perfluorocarbon liquid vitreous delamination and wide-angle viewing system in the management of complicated diabetic retinal detachment
    Yadarola, Maria B.
    Gramajo, Ana L.
    Arrambide, Maria P.
    Colombres, Gustavo A.
    Juarez, Claudio P.
    Luna, Jose D.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (03) : 452 - 459
  • [49] Perfluorocarbon liquid vitreous delamination and wide-angle viewing system in the management of complicated diabetic retinal detachment
    Fernando Arevalo, J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (02) : 490 - 490
  • [50] Autoclavable two-piece noncased wide-angle contact lens system for vitrectomy
    Shah, VA
    Chalam, KV
    OPHTHALMIC RESEARCH, 2004, 36 (02) : 94 - 97