Dynamic CT technique for assessment of wrist joint instabilities

被引:60
|
作者
Leng, Shuai [1 ]
Zhao, Kristin [2 ]
Qu, Mingliang [1 ]
An, Kai-Nan [2 ]
Berger, Richard [3 ]
McCollough, Cynthia H. [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Dept Orthoped Surg, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
computed tomography; 4D CT; dynamic imaging; joint instability; DISTAL RADIOULNAR LIGAMENTS; COMPUTED-TOMOGRAPHY; ANATOMIC RECONSTRUCTION; IMAGE-RECONSTRUCTION; TEMPORAL RESOLUTION; SPIRAL CT; MOTION; KINEMATICS; KNEE; FLUOROSCOPY;
D O I
10.1118/1.3577759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a 4D [three-dimensional (3D) + time] CT technique to capture high spatial and temporal resolution images of wrist joint motion so that dynamic joint instabilities can be detected before the development of static joint instability and onset of osteoarthritis (OA). Methods: A cadaveric wrist was mounted onto a custom motion simulator and scanned with a dual source CT scanner during radial-ulnar deviation. A dynamic 4D CT technique was utilized to reconstruct images at 20 equidistant time points from one motion cycle. 3D images of carpal bones were generated using volume rendering techniques (VRT) at each of the 20 time points and then 4D movies were generated to depict the dynamic joint motion. The same cadaveric wrist was also scanned after cutting all portions of the scapholunate interosseus ligament to simulate scapholunate joint instability. Image quality were assessed on an ordinal scale (1-4, 4 being excellent) by three experienced orthopedic surgeons (specialized in hand surgery) by scoring 2D axial images. Dynamic instability was evaluated by the same surgeons by comparing the two 4D movies of joint motion. Finally, dose reduction was investigated using the cadaveric wrist by scanning at different dose levels to determine the lowest radiation dose that did not substantially alter diagnostic image quality. Results: The mean image quality scores for dynamic and static CT images were 3.7 and 4.0, respectively. The carpal bones, distal radius and ulna, and joint spaces were clearly delineated in the 3D VRT images, without motion blurring or banding artifacts, at all time points during the motion cycle. Appropriate viewing angles could be interactively selected to view any articulating structure using different 3D processing techniques. The motion of each carpal bone and the relative motion among the carpal bones were easily observed in the 4D movies. Joint instability was correctly and easily detected in the scan performed after the ligament was cut by observing the relative motion between the scaphoid and lunate bones. Diagnostic capability was not sacrificed with a volume CT dose index (CTDIvol) as low as 18 mGy for the whole scan, with estimated skin dose of approximately 33 mGy, which is much lower than the threshold for transient skin erythema (2000 mGy). Conclusions: The proposed dynamic 4D CT imaging technique generated high spatial and high temporal resolution images without requiring periodic joint motion. Preliminary results from this cadaveric study demonstrate the feasibility of detecting joint instability using this technique. (c) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3577759]
引用
收藏
页码:S50 / S56
页数:7
相关论文
共 50 条
  • [21] WRINKLE CORNER - A TECHNIQUE OF EXTERNAL FIXATION FOR OPEN DISLOCATIONS OF THE WRIST JOINT
    BESSER, MIB
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1982, 14 (03): : 268 - 269
  • [22] Preliminary evaluation of a robotic measurement system for the assessment of wrist joint spasticity
    Falzarano, Valeria
    Petrella, Giulia
    Marini, Francesca
    Holmes, Michael W. R.
    Masia, Lorenzo
    Morasso, Pietro
    Zenzeri, Jacopo
    2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 539 - 544
  • [23] The instability of wrist joint and total wrist replacement
    Ma Jin-Xing
    Xu Yong-Qing
    中华创伤杂志英文版, 2016, 19 (01) : 49 - 51
  • [24] The instability of wrist joint and total wrist replacement
    Ma, Jin-Xing
    Xu, Yong-Qing
    CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (01) : 49 - 51
  • [25] SYNOVECTOMY OF THE WRIST JOINT
    REFIOR, HJ
    AKTUELLE RHEUMATOLOGIE, 1983, 8 (05) : 157 - 158
  • [26] Arthroscopy of the Wrist Joint
    Dienst, M.
    ARTHROSKOPIE, 2006, 19 (01) : 5 - 5
  • [27] Wrist joint arthrodesis. Technique and outcome [Handgelenkarthrodese technik und ergebnisse]
    Martini A.K.
    Der Orthopäde, 1999, 28 (10): : 907 - 912
  • [28] Wrist joint aspiration
    Flint, Julia D.
    Giles, Ian P.
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2012, 73 (01) : C2 - C4
  • [29] ARTHRODESIS OF WRIST JOINT
    MCJANNET, AHD
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (02): : 260 - 260
  • [30] ANATOMY OF WRIST JOINT
    LEWIS, OJ
    HAMSHERE, RJ
    BUCKNILL, TM
    JOURNAL OF ANATOMY, 1970, 106 : 539 - &