Noise characteristics of x-ray differential phase contrast CT

被引:5
|
作者
Zambelli, Joseph [1 ]
Li, Ke [1 ]
Bevins, Nicholas [1 ]
Qi, Zhihua [1 ]
Chen, Guang-Hong [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
关键词
CONE-BEAM CT; TOMOGRAPHY;
D O I
10.1117/12.878497
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The noise characteristics of x-ray differential phase contrast computed tomography (DPC-CT) were investigated. Both theoretical derivation and experimental results demonstrated that the dependence of noise variance on spatial resolution in DPC-CT follows an inverse linear law. This behavior distinguishes DPC-CT from conventional absorption based x-ray CT, where the noise variance varies inversely with the cube of the spatial resolution. This anomalous noise behavior in DPC-CT is due to the Hilbert filtering kernel used in the CT reconstruction algorithm, which equally weights all spatial frequency content. Additionally, we demonstrate that the noise power of DPC-CT is scaled by the inverse of spatial frequency and is highly concentrated at the low spatial frequencies, whereas conventional absorption CT increases in power at the high spatial frequencies.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Contrast-to-noise in X-ray differential phase contrast imaging
    Engel, Klaus J.
    Geller, D.
    Koehler, T.
    Martens, G.
    Schusser, S.
    Vogtmeier, G.
    Roessl, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S202 - S207
  • [2] Noise analysis of hard X-ray differential phase contrast imaging
    Huang Jian-Heng
    Du Yang
    Lei Yao-Hu
    Liu Xin
    Guo Jin-Chuan
    Niu Han-Ben
    ACTA PHYSICA SINICA, 2014, 63 (16)
  • [3] Interior tomography in x-ray differential phase contrast CT imaging
    Lauzier, Pascal Theriault
    Qi, Zhihua
    Zambelli, Joseph
    Bevins, Nicholas
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [4] A theoretical framework for comparing noise characteristics of spectral, differential phase-contrast and spectral differential phase-contrast x-ray imaging
    Mechlem, Korbinian
    Sellerer, Thorsten
    Viermetz, Manuel
    Herzen, Julia
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (06):
  • [5] An FBP image reconstruction algorithm for x-ray differential phase contrast CT
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [6] Noise analysis of grating-based x-ray differential phase contrast imaging
    Revol, Vincent
    Kottler, Christian
    Kaufmann, Rolf
    Straumann, Ulrich
    Urban, Claus
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (07):
  • [7] In situ phase contrast X-ray brain CT
    Linda C. P. Croton
    Kaye S. Morgan
    David M. Paganin
    Lauren T. Kerr
    Megan J. Wallace
    Kelly J. Crossley
    Suzanne L. Miller
    Naoto Yagi
    Kentaro Uesugi
    Stuart B. Hooper
    Marcus J. Kitchen
    Scientific Reports, 8
  • [8] In situ phase contrast X-ray brain CT
    Croton, Linda C. P.
    Morgan, Kaye S.
    Paganin, David M.
    Kerr, Lauren T.
    Wallace, Megan J.
    Crossley, Kelly J.
    Miller, Suzanne L.
    Yagi, Naoto
    Uesugi, Kentaro
    Hooper, Stuart B.
    Kitchen, Marcus J.
    SCIENTIFIC REPORTS, 2018, 8
  • [9] Spectral Differential Phase Contrast X-Ray Radiography
    Mechlem, Korbinian
    Sellerer, Thorsten
    Viermetz, Manuel
    Herzen, Julia
    Pfeiffer, Franz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (03) : 578 - 587
  • [10] Numerical comparison of X-ray differential phase contrast and attenuation contrast
    Hahn, Dieter
    Thibault, Pierre
    Bech, Martin
    Stockmar, Marco
    Schleede, Simone
    Zanette, Irene
    Rack, Alexander
    Weitkamp, Timm
    Sztrokay, Aniko
    Schlossbauer, Thomas
    Bamberg, Fabian
    Reiser, Maximilian
    Pfeiffer, Franz
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06): : 1141 - 1148