Monitoring of gustatory stimulation of salivary glands by diffusion-weighted MR imaging: Comparison of 1.5T and 3T

被引:30
|
作者
Habermann, C. R.
Gossrau, P.
Kooijman, H.
Graessner, J.
Cramer, M. C.
Kaul, M. G.
Reitmeier, F.
Jaehne, M.
Adam, G.
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Otorhinolaryngol, Hamburg, Germany
[3] Philips Med Syst, Best, Netherlands
[4] Siemens Med Solut, Hamburg, Germany
关键词
D O I
10.3174/ajnr.A0587
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Our aim was to compare different field strengths monitoring physiologic changes due to oral stimulation of parotid glands by using diffusion-weighted QW) echo-planar imaging (EPI). MATERIALS AND METHODS: Twenty-seven healthy volunteers were examined with a DW-EPI sequence at 1.5T and 3T before and after oral stimulation with commercially available lemon juice. The b factors used were 0, 500, and 1000 s/mm(2). Apparent diffusion coefficient (ADC) maps were evaluated with a manually placed region of interest including the entire parotid gland. For comparison of results, a Student t test was used on the basis of the mean of the volunteer median values. To compare both field strengths, we calculated the Pearson correlation coefficient (r). RESULTS: DW-EPI MR imaging visualized the parotid glands of all volunteers. With 1.5T, the mean ADC before stimulation was 1. 12 X 10(-3) mm(2)/s +/- 0.08 X 10(-3) mm(2)/s. After stimulation with lemon juice, the ADC increased to 1.18 X 10(-3) mm(2)/s +/- 0.09 X 10(-3) mm(2)/s. For 3T, the ADC before stimulation was 1.14 X 10(-3) mm(2)/S +/- 0.04 X 10(-3) mm(2)/s, with an increase to 1.17 X 10(-3) mm(2)/s 0.05 X 10(-3) mm(2) /s after stimulation, For both field strengths, the increase in ADC after stimulation was significant (P <.001). High correlations between both field strengths were found pre- and poststimulation (r = 0.955, and 0.936, respectively). CONCLUSION: DW-EPI MR imaging allows monitoring of physiologic changes due to oral stimulation of parotid glands by using DW imaging with high correlation between 1.5T and 3T.
引用
收藏
页码:1547 / 1551
页数:5
相关论文
共 50 条
  • [21] Diagnostic accuracy of diffusion-weighted imaging with conventional MR imaging for differentiating complex solid and cystic ovarian tumors at 1.5T
    Zhang, Ping
    Cui, Yanfen
    Li, Wenhua
    Ren, Gang
    Chu, Caiting
    Wu, Xiangru
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2012, 10
  • [22] Diagnostic accuracy of diffusion-weighted imaging with conventional MR imaging for differentiating complex solid and cystic ovarian tumors at 1.5T
    Ping Zhang
    Yanfen Cui
    Wenhua Li
    Gang Ren
    Caiting Chu
    Xiangru Wu
    World Journal of Surgical Oncology, 10
  • [23] Body Diffusion-weighted MR Imaging in Oncology: Imaging at 3 T
    Koh, Dow-Mu
    Lee, Jeong-Min
    Bittencourt, Leonardo Kayat
    Blackledge, Matthew
    Collins, David J.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2016, 24 (01) : 31 - +
  • [24] Diffusion-weighted imaging and the apparent diffusion coefficient on 3T MR imaging in the differentiation of craniopharyngiomas and germ cell tumors
    Kinoshita, Yasuyuki
    Yamasaki, Fumiyuki
    Tominaga, Atsushi
    Ohtaki, Megu
    Usui, Satoshi
    Arita, Kazunori
    Sugiyama, Kazuhiko
    Kurisu, Kaoru
    NEUROSURGICAL REVIEW, 2016, 39 (02) : 207 - 213
  • [25] Diffusion-weighted imaging and the apparent diffusion coefficient on 3T MR imaging in the differentiation of craniopharyngiomas and germ cell tumors
    Yasuyuki Kinoshita
    Fumiyuki Yamasaki
    Atsushi Tominaga
    Megu Ohtaki
    Satoshi Usui
    Kazunori Arita
    Kazuhiko Sugiyama
    Kaoru Kurisu
    Neurosurgical Review, 2016, 39 : 207 - 213
  • [26] MR IMAGING OF THE KNEE AT 3T-DIAGNOSTIC PERFORMANCE AND COMPARISON WITH 1.5T
    Van Dyck, P.
    JBR-BTR, 2014, 97 (02): : 126 - 127
  • [27] Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors
    Kim, Ji-hoon
    Chang, Kee-Hyun
    Na, Dong Gyu
    Song, In Chan
    Kim, Seung Ja
    Kwon, Bae Ju
    Han, Moon Hee
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (03) : 156 - 161
  • [28] Evaluation of primary adnexal masses by 3T MRI: categorization with conventional MR imaging and diffusion-weighted imaging
    He Zhang
    Guo-Fu Zhang
    Zhi-Yan He
    Zheng-Yu Li
    Ming Zhu
    Gui-Xiang Zhang
    Journal of Ovarian Research, 5
  • [29] Evaluation of primary adnexal masses by 3T MRI: categorization with conventional MR imaging and diffusion-weighted imaging
    Zhang, He
    Zhang, Guo-Fu
    He, Zhi-Yan
    Li, Zheng-Yu
    Zhu, Ming
    Zhang, Gui-Xiang
    JOURNAL OF OVARIAN RESEARCH, 2012, 5
  • [30] R2*imaging of transfusional iron burden at 3T and comparison with 1.5T
    Storey, Pippa
    Thompson, Alexis A.
    Carqueville, Christine L.
    Wood, John C.
    de Freitas, R. Andrew
    Rigsby, Cynthia K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 540 - 547