The effect of different chemoembolization materials on CT-based attenuation correction in PET/CT

被引:7
|
作者
Heusner, T. -A.
Fronz, U.
Jentzen, W.
Verhagen, R.
Forsting, M.
Bockisch, A.
Antoch, G.
机构
[1] Univ Klin Essen, Inst Diagnost & Intervent Radiol & Neuroradiol, D-45147 Essen, Germany
[2] Univ Klin Essen, Klin Nukl Med, Essen, Germany
关键词
PET-CT; chemoembolization; experimental study; hepatic arteries;
D O I
10.1055/s-2007-963402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Primary and secondary hypervascularized liver tumors may be treated with transarterial chemoembolization (TACE). The purpose of this study was to experimentally quantify the effect of different chemoembolization materials on the PET activity concentration in PET/CT. Materials and Methods: Different concentrations of lipiodol, tungsten, tantalum, and a different number of platinum coils embedded in a carrier substance were placed in a liver phantom. An insert filled with only the carrier substance served as the negative control. The liver phantom was placed in a body phantom. The liver phantom was filled with 63.3 KBq [18-F]-Fluor-2-deoxy-D-glucose (FDG)/ml water, the body phantom was filled with 19.7 KBq FDG/ml water. PET/CT was performed and PET attenuation correction was performed based on the CT data. We defined: Activity concentration over embolization material (kBq/ml) approximate to measured activity concentration; activity concentration over negative control (kBq/ml) approximate to real activity concentration. An overestimation of the activity concentration was quantified by the following ratio: Activity concentration overestimation = activity concentration over embolization material (kBq/ml)/activity concentration over negative control (kBq/ml). Results: All chemoembolization materials led to an overestimation of the PET activity concentration when using CT information for PET attenuation correction. The extent of overestimation is dependent on the concentration and the density of the chemoembolizing agent. PET activity overestimation was 11-151% with lipiodol, 34-1827% with tungsten, 16-1205% with tantalum, and 4-29% with platinum coils. Conclusion: Conventional chemoembolization materials cause an overestimation of the PET activity concentration in CT-based attenuation-corrected PET/CT images. This is of importance for the clinical routine since activity concentration quantification may not be used in the presence of chemoembolizing agents for imaging follow-up. If an increased FDG uptake is detected after transarterial chemoembolization, non-attenuation-corrected PET images must be assessed in addition to the attenuation-corrected images in order to differentiate artificially increased tracer uptake from a true increase in activity concentration of the tracer. The use of non-attenuating chemoembolizing materials (e.g. drug-eluting beads) for TACE may serve as an alternative to avoid embolization-associated PET artifacts.
引用
收藏
页码:1159 / 1165
页数:7
相关论文
共 50 条
  • [41] Simulation-based Assessment of the Impact of Contrast Medium on CT-based Attenuation Correction in PET
    Ay, Mohamad Reza
    Zaidi, Habib
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2731 - 2735
  • [42] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [43] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [44] CT-based attenuation correction in 82Rb-myocardial perfusion PET–CT: incidence of misalignment and effect on regional tracer distribution
    Riikka Lautamäki
    Tracy L. Y. Brown
    Jennifer Merrill
    Frank M. Bengel
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 305 - 310
  • [45] PET emission activities after 68GE-transmission correction or CT-based attenuation correction
    Buck, A
    Gubler, G
    Goerres, G
    Ross, S
    Ronn, A
    Altman, H
    Tokman, A
    vonSchulthess, G
    Burger, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 969 - 969
  • [46] Comparative Assessment of Different Energy Mapping Methods in CT-Based Attenuation Correction in PET/CT Systems Using Whole Body XCAT Phantom
    Soleymani, Elham
    Soleymani, Ali
    Ahmadi, Shahla
    Nordin, Md Jan
    4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI 2013), 2013, 11 : 962 - 973
  • [47] Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies
    Dizendorf, E
    Hany, TF
    Buck, A
    von Schulthess, GK
    Burger, C
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 732 - 738
  • [48] Comparison of Myocardial Perfusion 82Rb PET Performed with CT- and Transmission CT-Based Attenuation Correction
    Slomka, Piotr J.
    Le Meunier, Ludovic
    Hayes, Sean W.
    Acampa, Wanda
    Oba, Muneo
    Haemer, Gillian G.
    Berman, Daniel S.
    Germano, Guido
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (12) : 1992 - 1998
  • [49] Effect of respiratory motion correction and CT-based attenuation correction on dual-gated cardiac PET image quality and quantification
    Jussi Schultz
    Reetta Siekkinen
    Mojtaba Jafari Tadi
    Mika Teräs
    Riku Klén
    Eero Lehtonen
    Antti Saraste
    Jarmo Teuho
    Journal of Nuclear Cardiology, 2022, 29 : 2423 - 2433
  • [50] Evaluation and quality control of CT-based attenuation correction for PET/CT: potential influence on target volume delineation in radiotherapy
    Caselles, O
    Serre, D
    Girault, S
    Marre, D
    Doyeux, K
    Courbon, F
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S112 - S112