The effect of different chemoembolization materials on CT-based attenuation correction in PET/CT

被引:7
|
作者
Heusner, T. -A.
Fronz, U.
Jentzen, W.
Verhagen, R.
Forsting, M.
Bockisch, A.
Antoch, G.
机构
[1] Univ Klin Essen, Inst Diagnost & Intervent Radiol & Neuroradiol, D-45147 Essen, Germany
[2] Univ Klin Essen, Klin Nukl Med, Essen, Germany
关键词
PET-CT; chemoembolization; experimental study; hepatic arteries;
D O I
10.1055/s-2007-963402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Primary and secondary hypervascularized liver tumors may be treated with transarterial chemoembolization (TACE). The purpose of this study was to experimentally quantify the effect of different chemoembolization materials on the PET activity concentration in PET/CT. Materials and Methods: Different concentrations of lipiodol, tungsten, tantalum, and a different number of platinum coils embedded in a carrier substance were placed in a liver phantom. An insert filled with only the carrier substance served as the negative control. The liver phantom was placed in a body phantom. The liver phantom was filled with 63.3 KBq [18-F]-Fluor-2-deoxy-D-glucose (FDG)/ml water, the body phantom was filled with 19.7 KBq FDG/ml water. PET/CT was performed and PET attenuation correction was performed based on the CT data. We defined: Activity concentration over embolization material (kBq/ml) approximate to measured activity concentration; activity concentration over negative control (kBq/ml) approximate to real activity concentration. An overestimation of the activity concentration was quantified by the following ratio: Activity concentration overestimation = activity concentration over embolization material (kBq/ml)/activity concentration over negative control (kBq/ml). Results: All chemoembolization materials led to an overestimation of the PET activity concentration when using CT information for PET attenuation correction. The extent of overestimation is dependent on the concentration and the density of the chemoembolizing agent. PET activity overestimation was 11-151% with lipiodol, 34-1827% with tungsten, 16-1205% with tantalum, and 4-29% with platinum coils. Conclusion: Conventional chemoembolization materials cause an overestimation of the PET activity concentration in CT-based attenuation-corrected PET/CT images. This is of importance for the clinical routine since activity concentration quantification may not be used in the presence of chemoembolizing agents for imaging follow-up. If an increased FDG uptake is detected after transarterial chemoembolization, non-attenuation-corrected PET images must be assessed in addition to the attenuation-corrected images in order to differentiate artificially increased tracer uptake from a true increase in activity concentration of the tracer. The use of non-attenuating chemoembolizing materials (e.g. drug-eluting beads) for TACE may serve as an alternative to avoid embolization-associated PET artifacts.
引用
收藏
页码:1159 / 1165
页数:7
相关论文
共 50 条
  • [1] Effect of different Chemoembolization materials on CT-based PET attenuation correction in PET/CT
    Heusner, T. A.
    Fronz, U.
    Jentzen, W.
    Verhagen, R.
    Bockisch, A.
    Antoch, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S151 - S151
  • [2] Automated CT-based Attenuation Correction for Preclinical Multimodality PET/CT
    Chen, Mu
    Osborne, Dustin
    Gleason, Shaun
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4043 - +
  • [3] Accuracy of CT-based attenuation correction in PET/CT bone imaging
    Abella, Monica
    Alessio, Adam M.
    Mankoff, David A.
    MacDonald, Lawrence R.
    Jose Vaquero, Juan
    Desco, Manuel
    Kinahan, Paul E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [4] Accuracy of CT-Based attenuation correction in bone Imaging with PET/CT
    Abella, M.
    Mankof, D.
    Vaquero, J. J.
    Desco, M.
    Kinahan, P. E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4485 - +
  • [5] Effect of chemoembolizing agents on the CT-based PET attenuation correction in dual-modality PET/CT
    Antoch, G
    Fronz, U
    Veit, P
    Freudenberg, LS
    Jentzen, W
    Brandau, W
    Bockisch, A
    Verhagen, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S331 - S331
  • [6] CT-Based Attenuation Correction on the FLEX Triumph Preclinical PET/CT Scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 66 - 75
  • [7] CT-Based attenuation correction for PET/CT scanners in the presence of contrast agent
    Carney, J
    Beyer, T
    Brasse, D
    Yap, JT
    Townsend, DW
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1443 - 1446
  • [8] CT-based attenuation correction on the FLEX Triumph™ preclinical PET/CT scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3357 - +
  • [9] Comparison of different CT-based attenuation correction schemes for PET with respiratory motion.
    Qi, J
    Huesman, RH
    Reutter, BW
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 38P - 38P
  • [10] Effect of oral contrast agents on CT-based PET attenuation correction in dual-modality PET/CT tomography
    Antoch, G
    Jentzen, W
    Stattaus, J
    Mueller, SP
    Bockisch, A
    Debatin, JF
    RADIOLOGY, 2002, 225 : 423 - 424