Development and validation of a subject-specific finite element model of the functional spinal unit to predict vertebral strength

被引:16
|
作者
Lee, Chu-Hee [1 ]
Landham, Priyan R. [2 ]
Eastell, Richard [1 ,3 ]
Adams, Michael A. [2 ]
Dolan, Patricia [2 ]
Yang, Lang [1 ,3 ]
机构
[1] Univ Sheffield, Mellanby Ctr Bone Res, Sheffield S10 2RX, S Yorkshire, England
[2] Univ Bristol, Ctr Appl Anat, Bristol, Avon, England
[3] Univ Sheffield, INSIGNEO Inst Sil Med, Sheffield, S Yorkshire, England
关键词
Finite element (biomechanics); spine biomechanics; bone biomechanics; imaging (biomechanics); biomechanical testing; analysis; QUANTITATIVE COMPUTED-TOMOGRAPHY; BODY COMPRESSIVE STRENGTH; TRABECULAR BONE; INTERVERTEBRAL DISC; PROXIMAL FEMUR; MOTION SEGMENT; FRACTURE PREDICTION; THORACOLUMBAR SPINE; NUCLEUS PULPOSUS; ANATOMIC SITE;
D O I
10.1177/0954411917708806
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finite element models of an isolated vertebral body cannot accurately predict compressive strength of the spinal column because, in life, compressive load is variably distributed across the vertebral body and neural arch. The purpose of this study was to develop and validate a patient-specific finite element model of a functional spinal unit, and then use the model to predict vertebral strength from medical images. A total of 16 cadaveric functional spinal units were scanned and then tested mechanically in bending and compression to generate a vertebral wedge fracture. Before testing, an image processing and finite element analysis framework (SpineVox-Pro), developed previously in MATLAB using ANSYS APDL, was used to generate a subject-specific finite element model with eight-node hexahedral elements. Transversely isotropic linear-elastic material properties were assigned to vertebrae, and simple homogeneous linear-elastic properties were assigned to the intervertebral disc. Forward bending loading conditions were applied to simulate manual handling. Results showed that vertebral strengths measured by experiment were positively correlated with strengths predicted by the functional spinal unit finite element model with von Mises or Drucker-Prager failure criteria (R-2=0.80-0.87), with areal bone mineral density measured by dual-energy X-ray absorptiometry (R-2=0.54) and with volumetric bone mineral density from quantitative computed tomography (R-2=0.79). Large-displacement non-linear analyses on all specimens did not improve predictions. We conclude that subject-specific finite element models of a functional spinal unit have potential to estimate the vertebral strength better than bone mineral density alone.
引用
收藏
页码:821 / 830
页数:10
相关论文
共 50 条
  • [31] Simulation of orthotic treatment in adolescent idiopathic scoliosis using a subject-specific finite element model
    Vergari, C.
    Courtois, I.
    Ebermeyer, E.
    Bouloussa, H.
    Vialle, R.
    Skalli, W.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 : 2076 - 2077
  • [32] Instantaneous Generation of Subject-Specific Finite Element Models of the Hip Capsule
    Anantha-Krishnan, Ahilan
    Myers, Casey A.
    Fitzpatrick, Clare K.
    Clary, Chadd W.
    BIOENGINEERING-BASEL, 2024, 11 (01):
  • [33] In vivo evaluation of the subject-specific finite element model for knee joint cartilage contact area
    Kang, Kyoung-Tak
    Kim, Sung-Hwan
    Son, Juhyun
    Lee, Young Han
    Chun, Heoung-Jae
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2015, 16 (06) : 1171 - 1177
  • [34] Subject-specific finite element model with an optical tracking system in total hip replacement surgery
    Miles, Brad
    Kolos, Elizabeth
    Walter, William L.
    Appleyard, Richard
    Li, Qing
    Chen, Youngang
    Ruys, Andrew J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (04) : 280 - 290
  • [35] Achilles tendon stress is more sensitive to subject-specific geometry than subject-specific material properties: A finite element analysis
    Hansen, Wencke
    Shim, Vickie B.
    Obst, Steven
    Lloyd, David G.
    Newsham-West, Richard
    Barrett, Rod S.
    JOURNAL OF BIOMECHANICS, 2017, 56 : 26 - 31
  • [36] Development and validation of a subject-specific computational human knee model in a dynamic knee simulator
    Weimer, Katherine A.
    Guess, Trent M.
    Dodd, Kevin A.
    Maletsky, Lorin P.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 407 - 408
  • [37] Experimental validation of a subject-specific maximum endurance time model
    Liu, Bin
    Ma, Liang
    Chen, Chi
    Zhang, Zhanwu
    ERGONOMICS, 2018, 61 (06) : 806 - 817
  • [38] Subject-Specific Finite Element Modelling of the Human Hand Complex: Muscle-Driven Simulations and Experimental Validation
    Yuyang Wei
    Zhenmin Zou
    Guowu Wei
    Lei Ren
    Zhihui Qian
    Annals of Biomedical Engineering, 2020, 48 : 1181 - 1195
  • [39] Subject-Specific Finite Element Modelling of the Human Hand Complex: Muscle-Driven Simulations and Experimental Validation
    Wei, Yuyang
    Zou, Zhenmin
    Wei, Guowu
    Ren, Lei
    Qian, Zhihui
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (04) : 1181 - 1195
  • [40] Subject-specific knee joint model: Design of an experiment to validate a multi-body finite element model
    Oehman, C.
    Espino, D. M.
    Heinmann, T.
    Baleani, M.
    Delingette, H.
    Viceconti, M.
    VISUAL COMPUTER, 2011, 27 (02): : 153 - 159