Structure and behavior of water-laden CH4/air counterflow diffusion flames

被引:30
|
作者
Padilla, R. E. [1 ]
Escofet-Martin, D. [1 ]
Pham, T. [2 ]
Pitz, W. J. [3 ]
Dunn-Rankin, D. [1 ]
机构
[1] Univ Calif Irvine, Dept Mech & Aerosp Engn, 4200 Engn Gateway, Irvine, CA 92697 USA
[2] Calif State Univ Los Angeles, Dept Mech Engn, 5151 State Univ Dr, Los Angeles, CA 90032 USA
[3] Lawrence Livermore Natl Lab, Mat Sci Div, Livermore, CA 94551 USA
基金
美国国家科学基金会;
关键词
Water-laden; Counterflow; Dilution extinction; Nonpremixed; OH-PLIF; NOX EMISSION CHARACTERISTICS; THIN-FILAMENT PYROMETRY; POLLUTANT EMISSIONS; PREMIXED FLAMES; EXTINCTION; CO2; H2O; PRESSURES; PROGRESS; FLOW;
D O I
10.1016/j.combustflame.2018.06.037
中图分类号
O414.1 [热力学];
学科分类号
摘要
A counterflow configuration was used to measure thermal and species structure in water-vapor diluted nonpremixed methane-air flames. The motivation is to understand the chemical and thermal effects that water has when it is introduced as a diluent into the fuel side. This work is relevant to combustion processes where water is incorporated naturally in the fuel; e.g., methane hydrates, and when water is added intentionally for emission reduction such as in flares and H2O/fuel emulsions combustion. Experimental data are compared to 1-D computations. The agreement is generally very good, but the one dimensional counterflow diffusion model overpredicts flame temperature and major radical, OH, concentration very near extinction in highly diluted H2O-methane/air diffusion flames. Changes in flame position, flame width, and peak temperature with the addition of water were measured. Flame temperatures were measured with thin filament pyrometry. OH-PLIF is used to characterize the flame reaction zone with water dilution; the OH distribution, flame position and thickness from the OH-PLIF images were measured. The results show that the OH intensity and reaction zone thickness decreases with the increase in water. Predictions and experiments demonstrate that water mainly acts thermally to lower the flame temperature until extinction. The OH maximum intensity shifts towards the air side of the counterflow burner with water addition. OH is also measured with CO2 dilution of the fuel stream, and the results are compared with H2O addition, including comparisons with the OH molar peak predictions obtained using the GRI 3.0 mechanism and the CHEMKIN Pro one dimensional counterflow model. The study indicates that water's chemical effects are to change the production and depletion of OH, H and O radicals, especially near extinction. Chemical kinetics simulation of the flame demonstrates good agreement in OH and flame temperatures over a wide range of dilution away from extinction, particularly for CO2. An over prediction of the water carrying capacity near extinction is found for highly water-diluted flames. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:439 / 451
页数:13
相关论文
共 50 条
  • [31] The effect of hydrogen addition on flammability limit and NOx emission in ultra-lean counterflow CH4/air premixed flames
    Guo, HS
    Smallwood, GJ
    Liu, FS
    Ju, YG
    Gülder, ÖL
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2005, 30 (30): : 303 - 311
  • [32] Experimental study of the effect of water mist on CH4/air non-premixed flames
    Liu, Jianghong
    Liao, Guangxuan
    ISMSSE 2011, 2011, 26
  • [33] Chemiluminescence and Structure Characteristics in CH4/O2 Coflow Jet Diffusion Flames
    Gong, Yan
    Hu, Chonghe
    Guo, Qinghua
    Wu, Xiaoxiang
    Yu, Guangsuo
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1059 - 1064
  • [34] Influence of preheating and burner geometry on modeling the attachment of laminar coflow CH4/air diffusion flames
    Xu, Huanhuan
    Liu, Fengshan
    Sun, Shaozeng
    Zhao, Yijun
    Meng, Shun
    Tang, Wenbo
    Feng, Dongdong
    Gu, MingYan
    COMBUSTION AND FLAME, 2018, 191 : 381 - 393
  • [35] Flame inhibition activity of DMMP in opposed CH4/N2-air diffusion flames
    Siow, JE
    Laurendeau, NM
    COMBUSTION SCIENCE AND TECHNOLOGY, 2002, 174 (04) : 91 - 116
  • [36] NOx formation in counter-flow opposed-jet diffusion CH4/air flames
    Bonturi, S
    Pourkashanian, M
    Williams, A
    Oskam, G
    Wilson, C
    COMBUSTION SCIENCE AND TECHNOLOGY, 1996, 121 (1-6) : 217 - 233
  • [37] Diffusion of CH4 in amorphous solid water
    Mate, Belen
    Cazaux, Stephanie
    Angel Satorre, Miguel
    Molpeceres, German
    Ortigoso, Juan
    Millan, Carlos
    Santonja, Carmina
    ASTRONOMY & ASTROPHYSICS, 2020, 643
  • [38] TRANSIENT-BEHAVIOR OF LAMINAR COUNTERFLOW HYDROGEN AIR DIFFUSION FLAMES WITH COMPLEX CHEMISTRY
    DARABIHA, N
    COMBUSTION SCIENCE AND TECHNOLOGY, 1992, 86 (1-6) : 163 - 181
  • [39] Heat Release Rate Markers for Highly Stretched Premixed CH4/Air and CH4/H2/Air Flames
    Chen, Xinyi
    Wang, Yiqing
    Zirwes, Thorsten
    Zhang, Feichi
    Bockhorn, Henning
    Chen, Zheng
    ENERGY & FUELS, 2021, 35 (16) : 13349 - 13359
  • [40] Numerical studies of stretched CH4 -: air cylindrical premixed flames
    Mishra, DP
    FUEL, 2004, 83 (17-18) : 2345 - 2350