Dose conversion coefficients for CT examinations of adults with automatic tube current modulation

被引:32
|
作者
Schlattl, H. [1 ]
Zankl, M. [1 ]
Becker, J. [1 ]
Hoeschen, C. [1 ]
机构
[1] Helmholtz Zentrum Munchen, Natl Res Ctr Environm Hlth, Dept Med Radiat Phys & Diagnost, D-85764 Oberschleissheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 20期
关键词
AXIAL SCANNING TOMOGRAPHY; RADIATION-EXPOSURE; VOXEL MODELS; REDUCTION; FEMALE;
D O I
10.1088/0031-9155/55/20/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic tube current modulation (TCM) is used in modern CT devices. This is implemented in the numerical calculation of dose conversion coefficients for CT examinations. For four models of adults, the female and male reference models of ICRP and ICRU and a lighter and a heavier female model, dose conversion coefficients normalized to CTDIvol (DCCCT) have been computed with a Monte Carlo transport code for CT scans with and without TCM. It could be shown for both cases that reliable values for spiral CT scans are obtained when combining the results from an appropriate set of axial scans. The largest organ DCCCT are presented for typical CT examinations for all four models. The impact of TCM is greatest for chest, pelvis and whole-trunk CT examinations, where with TCM the effective DCCCT can be 20-25% lower than without TCM. Typical organs with strong dependence on TCM are thyroid, urinary bladder, lungs and oesophagus. While the DCCCT of thyroid and urinary bladder are mainly sensitive to angular TCM, the DCCCT of lungs and oesophagus are influenced primarily by longitudinal TCM. The impact of the body stature on the effective DCCCT is of the same order as the effect of TCM. Thus, for CT scans in the trunk region, accurate dose values can only be obtained when different sets of DCCCT are employed that are appropriate for the patient's sex and stature and the actual TCM settings.
引用
收藏
页码:6243 / 6261
页数:19
相关论文
共 50 条
  • [21] Relating Noise to Image Quality Indicators in CT Examinations With Tube Current Modulation
    Solomon, Justin B.
    Li, Xiang
    Samei, Ehsan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 592 - 600
  • [22] Absorption dose reduction by tube current modulation in CT system
    Nagaoka, T
    Miyazaki, O
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 719 - 731
  • [23] Patient Specific Tube Current Modulation for CT Dose Reduction
    Jin, Yannan
    Yin, Zhye
    Yao, Yangyang
    Wang, Hui
    Wu, Mingye
    Kalra, Mannudeep
    De Man, Bruno
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [24] Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis
    Lee, Sanghee
    Yoon, Sang-Wook
    Yoo, Seung-Min
    Ji, Young Geon
    Kim, Kyoung Ah
    Kim, Sang Heum
    Lee, Jong Tae
    ACTA RADIOLOGICA, 2011, 52 (10) : 1101 - 1106
  • [25] CTDIvol: a suitable normalization for CT dose conversion coefficients at different tube voltages?
    Schlattl, Helmut
    Zankl, Maria
    Hoeschen, Christoph
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [26] Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
    Leswick, David A.
    Hunt, Megan M.
    Webster, Steven T.
    Fladeland, Derek A.
    RADIOLOGY, 2008, 249 (02) : 572 - 580
  • [27] Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation
    Campbell, J
    Kalra, MK
    Rizzo, S
    Maher, MM
    Shepard, JA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) : 1525 - 1530
  • [28] Metallic prosthesis: Technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients
    Dalal, T
    Kalra, MK
    Rizzo, SMR
    Schmidt, B
    Suess, C
    Flohr, T
    Blake, MA
    Saini, S
    RADIOLOGY, 2005, 236 (02) : 671 - 675
  • [29] Evaluation of an organ-based tube current modulation tool in pediatric CT examinations
    Papadakis, Antonios E.
    Damilakis, John
    EUROPEAN RADIOLOGY, 2020, 30 (10) : 5728 - 5737
  • [30] Evaluation of an organ-based tube current modulation tool in pediatric CT examinations
    Antonios E. Papadakis
    John Damilakis
    European Radiology, 2020, 30 : 5728 - 5737