Spray characteristics determination of water mist for suppressing pool fire

被引:0
|
作者
Zheng, Li G. [1 ,2 ]
Yu, Ming G. [1 ]
Yu, Shui J. [1 ]
Liu, Zhi C. [1 ]
机构
[1] Henan Polytech Univ, Sch Safety Sci & Engn, Jiaozuo 454003, Henan, Peoples R China
[2] Zhejiang Univ, Inst Thermal Power Engn, Hangzhou 310027, Peoples R China
来源
MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS | 2007年 / 914卷
关键词
water mist; fire suppression; two-phase flow; measurement;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To optimize the design of a water mist fire suppression system or to provide input data and validation data for field models, the characteristics of the water mist field are needed. This data typically consists of the distribution of droplet sizes and velocities. In this research a LS2000 Laser Sizer has been proposed to simultaneously determine spray characteristics of 408 kinds of self-developed nozzles for fire suppression. The results of LS2000 Laser Sizer measurements to characterize the water mist produced by nozzles for suppressing pool fire are presented. These data can provide a foundation to the design and optimization of additive-containing WMFSS. To explore the effect of the water pressure on the droplet size distribution and spray velocity, data from three typical pressures of 0.9MPa, 1.2Mpa and I.5MPa have been obtained. With the measured average size and distribution of droplets, a comparison between three nozzles was made in the pressure of 1.5MPa to investigate the influence of the nozzle design parameters on atomizing characteristics. The results show that representative size of droplets decreases slightly and the water flow rate increases with the water pressure to the nozzle head P., and the droplet velocity of water mist is approximately directly proportional to P.. The trends that the nozzles with the larger D-32 have a wider range of droplet diameter distribution and their volume fraction curves shift towards the large diameter direction are also found in measurements. This will be favorable to the extinguishment of kerosene pool fire. The water flux density distribution results demonstrated that the water flux density over the cross section was very non-uniform when the water mist nozzle is improperly designed.
引用
收藏
页码:530 / +
页数:3
相关论文
共 50 条
  • [41] Determination of Operating Parameters for the Use of an Electrostatically Charged Water Spray Mist
    Zillgitt, Marcel
    Schmidt, Eberhard
    CHEMICAL ENGINEERING & TECHNOLOGY, 2021, 44 (07) : 1178 - 1184
  • [42] Effect of low ambient air pressure on spray characteristics of water mist
    Wang, Xishi
    Zhu, Pei
    Li, Yuan
    Ni, Xiaomin
    Fan, Minghao
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 66 : 7 - 12
  • [43] A novel method to evaluate fire test performance of water mist and water spray total compartment protection
    Arvidson, Magnus
    JOURNAL OF FIRE PROTECTION ENGINEERING, 2013, 23 (04) : 277 - 299
  • [44] Experimental Study on Characteristics of Water Mist Fire Suppression for Cooking Fume
    Xie, Zhengwen
    Jiang, Zhengpei
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 596 - 601
  • [45] The influence of fine water mist on characteristics of small-scale fire
    Xu, Q
    Qin, J
    Lia, GX
    THERMOSENSE XXV, 2003, 5073 : 139 - 147
  • [46] Atomization parameters and fire suppression characteristics of water mist in simulated roadway
    Guo, Qing
    Ren, Wanxing
    GEOMATICS NATURAL HAZARDS & RISK, 2019, 10 (01) : 1529 - 1541
  • [47] Influence of Water Mist Nozzle Characteristic Parameters on Oil Pool Fire Extinguishing in Confined Space
    Gui, Xiaohong
    Xue, Haiteng
    Hu, Zhengyu
    Cui, Zehui
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (03) : 3441 - 3454
  • [48] Control effect on diesel pool fire by longitudinal smoke discharge and high pressure water mist
    Zhang, Peihong
    Feng, Rui
    Xu, Wenbin
    Tian, XiangLiang
    Shang, Rongxue
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 2798 - +
  • [49] Experimental and numerical study on kerosene pool fire suppression with water mist in a standard confined compartment
    Zheng, LG
    Yu, MG
    Xing, ZF
    Liu, ZC
    Zuo, QL
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1187 - 1192
  • [50] CFD-based study and analysis on the effectiveness of water mist in interacting pool fire suppression
    Dasgotra, Ankit
    Rangarajan, Goutham
    Tauseef, S. M.
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 152 : 614 - 629