Thermal power measurement of the novel evacuated tube solar collector and conventional solar collector during simultaneous operation

被引:25
|
作者
Rybar, Radim [1 ]
Beer, Martin [1 ]
Cehlar, Michal [1 ]
机构
[1] Tech Univ Kosice, Fac Min Ecol Proc Control & Geotechnol, Dept Earth Resources, Letna 9, Kosice 04200, Slovakia
关键词
Thermal power measuring; Evacuated tube solar collector; Metal foam; Simultaneous operation; HEAT-PIPE; FLAT-PLATE; PERFORMANCE EVALUATION; SYSTEMS; EXCHANGERS; NANOFLUIDS; PREDICTION; PLATFORM; COOKER; DESIGN;
D O I
10.1016/j.measurement.2016.03.054
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper deals with a description of the measurement method and evaluation of the thermal power of evacuated tube solar collectors (ETSC) during their simultaneous operation at the Centre of Renewable Energy Sources, Technical University of Kosice, Slovakia. Evaluation was performed during various climatic and solar irradiance conditions on experimental measuring apparatus, that was designed and manufactured by authors. Key feature of measuring apparatus is its ability to ensure simultaneous operation of both evaluated collectors. This method of operation was selected in order to ensure identical conditions for both evaluated solar collectors during all performed measurements. Within the evaluation were investigated two types of ETSC - one with a conventional manifold header, and the other with a parallel flow manifold header with metal foam structural element that was proposed by authors and it is under patent protection. The main objective of the comparison was to evaluate the effect of used metal foam structure and changes in inner configuration on the overall thermal power of the proposed solar collector through outdoor quasi dynamic test. Part of measurement was also devoted to pressure drop analysis of proposed prototype of manifold header. Within the presented measurements, ETSC with parallel flow manifold header with metal foam structural element demonstrated significant thermal power increase ranging from 85.2 to 201.8W per 1 m(2) of collector area (depending on used flow rates of heat transfer medium) and increase of performance enhancement factor in range from 1.14 to 3.20. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:153 / 164
页数:12
相关论文
共 50 条
  • [31] Developments of CPC solar evacuated glass tube collector with a novel selective coating
    Ma, Guangbai
    Yin, Zhiqiang
    Liu, Xijie
    Qi, Jing
    Dai, Yanjun
    SOLAR ENERGY, 2021, 220 : 1120 - 1129
  • [32] Comparative Studies on the Efficiency of Solar Flat-plate Collector and Evacuated Tube Collector
    Yan, Huilei
    Zhang, Hua
    Shao, Qiuping
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 3 - 8
  • [33] Comparative Study of Different Tube Geometries of Evacuated Tube Solar Collector
    Sonowal, Juri
    Bhowmik, Mrinal
    Muthukumar, P.
    Anandalakshmi, R.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (05):
  • [34] Performance of evacuated tube solar collector integrated solar desalination unit - a review
    Kumar, Rajeev
    Singh, Desh Bandhu
    Dewangan, Ashish
    Singh, Vivek Kumar
    Kumar, Navneet
    DESALINATION AND WATER TREATMENT, 2021, 230 : 92 - 115
  • [35] Photo-thermal design and analysis of a novel CPC coupled solar air evacuated tube collector
    Xu, Zhibo
    Bie, Yu
    Chen, Fei
    Krolczykg, Grzegorz
    Tu, Jielei
    Li, Zhixiong
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [36] A modified solar desalination system using evacuated tube collector
    Shafii, M. B.
    Mamouri, S. Jahangiri
    Lotfi, M. M.
    Mosleh, H. Jafari
    DESALINATION, 2016, 396 : 30 - 38
  • [37] Failure Investigation of Evacuated Tube Solar Collector of Water Heater
    Siddharaj V. Kumbhar
    Journal of Failure Analysis and Prevention, 2019, 19 : 1202 - 1206
  • [38] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [39] Targeting and Design of Evacuated-Tube Solar Collector Networks
    Picon-Nunez, Martin
    Martinez-Rodriguez, Guillermo
    Fuentes-Silva, Amanda L.
    PRES2016: 19TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELING AND OPTIMIZATION FOR ENERGY SAVINGS AND POLLUTION REDUCTION, 2016, 52 : 859 - 864
  • [40] The Experimental Investigation of a Solar Still Coupled with an Evacuated Tube Collector
    Sampathkumar, K.
    Arjunan, T. V.
    Senthilkumar, P.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2013, 35 (03) : 261 - 270