Corrosion evaluation of post-tensioned tendons on the Mid-Bay Bridge in Destin, Florida

被引:0
|
作者
Venugopalan, S [1 ]
Hartt, WH [1 ]
Powers, RG [1 ]
机构
[1] Florida Atlantic Univ, Dept Ocean Engn, Dania, FL USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion and corrosion-related tendon failures have been disclosed on several segmental box girder bridges in Florida. One of these was the Mid-Bay Bridge near Destin where as many as 11 tendons were replaced. Additionally, many other tendons exhibited cracking of the polyethylene duct. The visual inspection of this bridge revealed (1) corrosion of tendons and individual wires that ranged from minimal to severe, (2) presence of broken wires, and (3) cracking of the polyethylene duct. Extensive cracking of the polyethylene ducts was not the primary cause of tendon corrosion problems. However, it does serve as a corrosion promoter by providing greater moisture, oxygen, and chloride access to the steel. Based upon the various field and laboratory findings, a mechanism of tendon corrosion is proposed. Susceptibility of a particular tendon to deterioration by this cause should vary depending upon the extent to which deleterious conditions are present.
引用
收藏
页码:243 / 253
页数:11
相关论文
共 50 条
  • [21] Secondary anchorage in post-tensioned bridge systems
    1600, American Concrete Institute (110):
  • [22] Post-tensioned Flat Slabs with Unbonded Tendons for Public Buildings
    Torok, Iosif
    Puskas, Attila
    Virag, Jacint
    12TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING (INTER-ENG 2018), 2019, 32 : 102 - 109
  • [23] Parametric study for post-tensioned composite beams with external tendons
    El-Zohairy, Ayman
    Salim, Hani
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (10) : 1433 - 1450
  • [24] Elongation Tolerance for Short Tendons in Post-Tensioned Building Structures
    Hayek, Carol
    Kang, Thomas H. -K.
    ACI STRUCTURAL JOURNAL, 2017, 114 (04) : 795 - 802
  • [25] Evaluation and Restoration of Corrosion-Damaged Post-Tensioned Concrete Structures
    Alsuwaidi, Hadif
    Al-Sadoon, Zaid A.
    Altoubat, Salah
    Barakat, Samer
    Junaid, M. Talha
    Maalej, Mohamed
    Metawa, Abdulrahman
    Habib, Ahed
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2024, 10 (12): : 3834 - 3850
  • [26] Fungal influenced corrosion of post-tensioned cables
    Little, B
    Staehle, R
    Davis, R
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2001, 47 (02) : 71 - 77
  • [27] Corrosion risk of bonded, post-tensioned concrete
    Salas, Ruben M.
    Schokker, Andrea J.
    West, Jeff S.
    Breen, John E.
    Kreger, Michael E.
    PCI JOURNAL, 2008, 53 (01): : 89 - 107
  • [28] Health Monitoring of Prestressing Tendons in Post-tensioned Concrete Structures
    Salamone, Salvatore
    Bartoli, Ivan
    Nucera, Claudio
    Phillips, Robert
    di Scalea, Francesco Lanza
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2011, 2011, 7981
  • [29] Corroded post-tensioned beams with bonded tendons and wire failure
    Coronelli, Dario
    Castel, Arnaud
    Vu, Ngoc Anh
    Francois, Raoul
    ENGINEERING STRUCTURES, 2009, 31 (08) : 1687 - 1697
  • [30] DFEM of a post-tensioned precast concrete segmental bridge with unbonded external tendons subjected to prestress changes
    Yuen, Terry Y. P.
    Halder, Rudhra
    Chen, Wang-Wen
    Zhou, Xiangming
    Deb, Trissa
    Liu, Yang
    Tseng, Yang
    Wen, Tzu-Han
    STRUCTURES, 2020, 28 : 1322 - 1337