Hardness evaluation of a dental composite polymerized with experimental LED-based devices

被引:104
|
作者
Kurachi, C
Tuboy, AM
Magalhaes, DV
Bagnato, VS
机构
[1] Univ Sao Paulo, Sao Carlos Inst Phys, BR-13560970 Sao Carlos, SP, Brazil
[2] MM Opt, BR-13560050 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
light emitting diode; composite resin; cure; microhardness;
D O I
10.1016/S0109-5641(00)00088-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The main goal of this study was the hardness evaluation of a composite resin cured by five LED (Light Emitting Diodes) based devices and a comparison with a conventional curing unit. The hardness test was used to compare the efficacy of both types of light source. Methods: The LED-based devices were made employing an array of LEDs (Nichia Chem. Ind., Japan) emitting light peaked at 470 nm. Composite resin (Z100, shade A3) was cued for 20, 40, 60, 120 and 180 s with each LED-based device and for 40 s with the halogen lamp. The composite samples were prepared with 0.35, 1.25 and 1.8 mm of thickness. Five samples of each set of parameters were done. The hardness evaluation was performed at the non-illuminate surface with three indentations for each sample. Results: All the samples cured by the LED-based devices showed inferior hardness values when compared with the halogen lamp at the typical curing time (40 s). The L6 (device composed of six LEDs) was the most efficient one of the LED-based devices. Its obtained irradiance was 79 mW/cm(2), whereas the halogen lamp irradiance was of 475 mW/cm(2). For the L6 device here presented, longer exposure times or a thinner resin layer are required to achieve reasonable hardness values. Significance: Besides the difference of irradiance when compared with halogen lamps, LED-based devices show to be a promising alternative curing instrument. Further development in instrumentation may result in devices even more efficient than conventional lamps. (C) 2001 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 50 条
  • [41] Polymerization shrinkage evaluation in experimental dental composite filled with montmorillonite nanoparticles
    Luiza M. P. Campos
    Letícia C. Boaro
    Tamiris M. R. Santos
    Vinícius J. Santos
    Rebeca Grecco-Romano
    Mariana J. Santos
    Duclerc F. Parra
    Journal of Thermal Analysis and Calorimetry, 2018, 131 : 771 - 774
  • [42] Polymerization shrinkage evaluation in experimental dental composite filled with montmorillonite nanoparticles
    Campos, Luiza M. P.
    Boaro, Leticia C.
    Santos, Tamiris M. R.
    Santos, Vinicius J.
    Grecco-Romano, Rebeca
    Santos, Mariana J.
    Parra, Duclerc F.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2018, 131 (01) : 771 - 774
  • [43] Impact of Solder-Joint Tilting on the Reliability of LED-based PCB Assemblies: A Combined Experimental and FEM Analysis
    Vandevelde, Bart
    Zanon, Franco
    Griffoni, Alessio
    Li, Xiaolong
    Willems, Geert
    Meneghini, Matteo
    2015 16TH INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS (EUROSIME), 2015,
  • [45] Exploring the Effects of LED-Based Visible Light Communication on Reading and Color Perception in Indoor Environments: An Experimental Study
    Caputo, Stefano
    Mucchi, Lorenzo
    Comparetto, Regina
    D'Antoni, Vittoria
    Farini, Alessandro
    Orsi, Valentina
    Baldanzi, Elisabetta
    SENSORS, 2023, 23 (06)
  • [46] Mineral Trioxide Aggregate (MTA) as a filler in dental composite: Evaluation of micro-hardness and wear properties
    Kumar, Shiv Ranjan
    Patnaik, Amar
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2023, 237 (05) : 1988 - 1998
  • [47] Vicker's hardness and Raman spectroscopy evaluation of a dental composite cured by an argon laser and a halogen lamp
    Soares, LES
    Martin, AA
    Pinheiro, ALB
    Pacheco, MTT
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (03) : 601 - 608
  • [48] Evaluation of the Pink Luminous Breast LED-Based Technology Device as a Screening Tool for the Early Detection of Breast Abnormalities
    Ocasio-Villa, Fernando
    Morales-Torres, Luisa
    Velez-Medina, Norma
    Cubano, Luis A.
    Orengo, Juan C.
    Suarez Martinez, Edu B.
    FRONTIERS IN MEDICINE, 2022, 8
  • [49] Evaluation of different general V(?) mismatch indices of photometers for LED-based light sources in general lighting applications
    Krueger, Udo
    Ferrero, Alejandro
    Mantela, Ville
    Thorseth, Anders
    Trampert, Klaus
    Pellegrino, Olivier
    Sperling, Armin
    METROLOGIA, 2022, 59 (06)
  • [50] Experimental Techniques and FEM Simulation for Evaluation of Thermo-Mechanical Stress in LED Devices
    Pfeiler-Deutschmann, M.
    Rosc, J.
    Hammer, H.
    Brunner, R.
    Parteder, G.
    Hlina, W.
    Maier, G.
    Defregger, St
    Kraker, E.
    LED LIGHTING TECHNOLOGIES - WINNING APPROACHES, LPS 2014, 2014, : 32 - 39