Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?

被引:2
|
作者
Velez, Dencel A. Garcia [1 ]
Headford, Mikel [1 ]
Suresh, Krishna Vangipuram [1 ]
Liberatos, Paraskevi Marousa [1 ]
Bledsoe, Gary [2 ]
Revak, Thomas [1 ]
机构
[1] St Louis Univ Hosp, St Louis, MO 63104 USA
[2] Dept Biomech Engn, St Louis, MO USA
关键词
Bicondylar tibial plateau fracture; Elderly; Osteoporosis; Dual versus lateral plating; Biomechanics; Medial comminution; LESS INVASIVE STABILIZATION; INTERNAL-FIXATION; OPEN REDUCTION; POSTEROMEDIAL FRAGMENT; OPERATIVE TREATMENT; PATIENTS OLDER; LOCKING PLATE; OUTCOMES; SINGLE; COMPLICATIONS;
D O I
10.1016/j.injury.2022.08.039
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess dual plating versus lateral locked plate fixation of bicondylar tibial plateau fractures in an elderly cadaveric model with and without medial bone loss Participants: 10 pairs of elderly (range 78-93 years of age) fresh frozen tibias. Intervention: Bicondylar tibial plateau fractures were created reproducing AO/OTA 41 C1 (without medial bone loss) and C2 fractures (with medial bone loss). Cadavers were randomized to 4 different groups. Groups 1 and 2 were 41 C1 fractures and fixated with either dual or lateral plating, respectively. Groups 3 and 4 were fixated in a similar fashion with medial metaphyseal bone loss (41 C2 fracture) with dual plating Group 3 and lateral plating group 4. Lateral plating consisted of a 3.5 mm 5-hole lateral plate (ALPS, ZimmerBiomet) with 6 bicortical locking screws proximally and two diaphyseal screws. Dual plat-ing groups underwent lateral plating and additional 3.5 mm 5-hole posteromedial 1/3 tubular plate (Zim-merBiomet) placed at the apex of the fracture with two shaft screws and one unicortical screw proxi-mally. Specimens were tested in a Mechanical Testing System (MTS) machine loading both condyles. Outcome measurements: Specimens were loaded to 300 N and coronal alignment obtained. Specimens were then cycled from 100 N to 700 N for 5000 cycles at 2 Hz. Average axial displacement, maximal displacement, average force and coronal alignment after 50 0 0 cycles were recorded. Lastly, force to failure was recorded at 100 N/sec. Results: Mean axial displacement was 4.21 mm ranging from 3.12 mm in group 1 to 5.92 mm in group 4 ( P = 0.51). Failure force averaged 3340 N ranging from 4342 N in group 1 to 2433 N in group 4 ( P = 0.36). Maximal displacement ranged from 3.69 mm in group 1 to 7.37 mm in group 4 ( P = 0.21). Change in coronal alignment ranged from 0.98 degrees in group 1 to 1.97 degrees in group 4 ( P = 0.45). No statistically significant difference was noted between all four groups for all data points. Conclusion: The results of this study demonstrate that a lateral locked plate may offer an alternative means of fixation in AO/OTA 41 C1 and C2 fractures. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3109 / 3114
页数:6
相关论文
共 50 条
  • [21] BIOMECHANICAL COMPARISON OF MEDIAL VERSUS LATERAL SIDED PLATING IN FEMORAL FRACTURES
    Al, Firat
    Tosun, Bilgehan
    Sinmazcelik, Tamer
    Ozmen, Mustafa
    ACTA ORTOPEDICA BRASILEIRA, 2018, 26 (04): : 265 - 270
  • [22] Functional outcomes of severe bicondylar plateau fractures treated with dual incisions and medial and lateral plates
    Barei, David P.
    Nork, Sean E.
    Mills, William J.
    Coles, Chad P.
    Henley, M. Bradford
    Benirschke, Stephen K.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08): : 1713 - 1721
  • [23] Single versus dual incision approaches for dual plating of bicondylar tibial plateau fractures have comparable rates of deep infection and revision surgery
    Guild, Theodore T.
    Stenquist, Derek S.
    Yeung, Caleb M.
    Harris, Mitchel B.
    Von Keudell, Arvind G.
    Smith, R. Malcolm
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3475 - 3480
  • [24] Complications of High-Energy Bicondylar Tibial Plateau Fractures Treated With Dual Plating Through 2 Incisions
    Ruffolo, Michael R.
    Gettys, Franklin K.
    Montijo, Harvey E.
    Seymour, Rachel B.
    Karunakar, Madhav A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (02) : 85 - 90
  • [25] Acute versus staged fixation of bicondylar tibial plateau fractures: a dual centre international study
    Mesa, Lazaro
    Lufrano, Reuben C.
    Sajid, Mir Ibrahim
    Flanagan, Christopher
    Grewal, Ishvinder S.
    Bates, Peter
    Mir, Hassan R.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (03): : 1683 - 1690
  • [26] Acute versus staged fixation of bicondylar tibial plateau fractures: a dual centre international study
    Lazaro Mesa
    Reuben C. Lufrano
    Mir Ibrahim Sajid
    Christopher Flanagan
    Ishvinder S. Grewal
    Peter Bates
    Hassan R. Mir
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 1683 - 1690
  • [27] Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study
    Thamyongkit, Sorawut
    Abbasi, Pooyan
    Parks, Brent G.
    Shafiq, Babar
    Hasenboehler, Erik A.
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [28] Outcome Analysis of Dual Plating in Management of Unstable Bicondylar Tibial Plateau Fracture - A Prospective Study
    Raj, M.
    Gill, S. P. S.
    Rajput, A.
    Singh, K. S.
    Verma, K. S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (03) : 29 - 35
  • [29] Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study
    Sorawut Thamyongkit
    Pooyan Abbasi
    Brent G. Parks
    Babar Shafiq
    Erik A. Hasenboehler
    BMC Musculoskeletal Disorders, 23
  • [30] Stabilization of the Posteromedial Fragment in Bicondylar Tibial Plateau Fractures: A Mechanical Comparison of Locking and Nonlocking Single and Dual Plating Methods
    Yoo, Brad J.
    Beingessner, Daphne M.
    Barei, David P.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (01): : 148 - 155